메뉴 건너뛰기




Volumn 2, Issue , 2003, Pages 1132-1135

3-D comb electrodes for amperometric immuno sensors

Author keywords

Amperometric sensors; Biochemistry; Chemical sensors; Circuit testing; Electrodes; Fabrication; Immune system; Resists; Substrates; System testing

Indexed keywords

ACTUATORS; AMPEROMETRIC SENSORS; BIOCHEMISTRY; CHEMICAL SENSORS; ELECTRODES; ENZYME ELECTRODES; ENZYMES; FABRICATION; IMMUNE SYSTEM; MICROSYSTEMS; SOLID-STATE SENSORS; SUBSTRATES; TRANSDUCERS;

EID: 84859734589     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/SENSOR.2003.1216969     Document Type: Conference Paper
Times cited : (7)

References (5)
  • 1
    • 33845280298 scopus 로고
    • Solid-State Voltammetry in a Three-Electrode Electrochemical Cell-on-a-Chip with a Microlithographically Defined Microelectrode
    • Masao Morita, M.L.Longmire, and Royce W.Murray, "Solid-State Voltammetry in a Three-Electrode Electrochemical Cell-on-a-Chip with a Microlithographically Defined Microelectrode", Anal. Chem., 60,2770-2775, 1988.
    • (1988) Anal. Chem. , vol.60 , pp. 2770-2775
    • Morita, M.1    Longmire, M.L.2    Murray, R.W.3
  • 2
    • 0025304397 scopus 로고
    • Electrochemical Behavior of Reversible Redox Species at Interdigitated Array Electrodes with Different Geometries: Consideration of Redox Cycling and Collection Efficiency
    • Osamu Niwa, Masao Morita and Hisao Tabei, "Electrochemical Behavior of Reversible Redox Species at Interdigitated Array Electrodes with Different Geometries: Consideration of Redox Cycling and Collection Efficiency", Anal Chem., 62, 447-452, 1990.
    • (1990) Anal Chem. , vol.62 , pp. 447-452
    • Niwa, O.1    Morita, M.2    Tabei, H.3
  • 3
    • 0027615898 scopus 로고
    • Small-Volume Voltammetric Detection of 4-Aminophenol with Interdigitated Array Electrodes and Its Application to Electrochemical Enzyme Immunoassay
    • Osamu Niwa, Yan Xu, H.Brian Halsall, and William R.Heineman, "Small-Volume Voltammetric Detection of 4-Aminophenol with Interdigitated Array Electrodes and Its Application to Electrochemical Enzyme Immunoassay", Anal.Chem., 65,1559-1563,1993.
    • (1993) Anal.Chem. , vol.65 , pp. 1559-1563
    • Niwa, O.1    Xu, Y.2    Halsall, H.B.3    Heineman, W.R.4
  • 5
    • 0000127753 scopus 로고
    • P-Aminophenyl Phosphate:an Improved Substrate for Electrochemical Enzyme Immunoassay
    • Hua T.Tang, Craig E.Lunte, H.Brian Halsall and William R.Heineman, "p-Aminophenyl Phosphate:an Improved Substrate for Electrochemical Enzyme Immunoassay", Anal.Chem.Acta,214, 187-195, 1988.
    • (1988) Anal.Chem.Acta , vol.214 , pp. 187-195
    • Tang, H.T.1    Lunte, C.E.2    Halsall, H.B.3    Heineman, W.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.