메뉴 건너뛰기




Volumn 90, Issue APRIL, 2009, Pages 6-9

Enhancement in solar water heater performance using twisted tape inserts

Author keywords

Collector heat removal factor; Swirl Reynolds number; Thermal enhancement factor; Twist pitch ratio; Twisted tape

Indexed keywords

HEAT REMOVAL; REYNOLDS; THERMAL ENHANCEMENT; TWIST PITCH; TWISTED TAPES;

EID: 84859570469     PISSN: 00203408     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (8)

References (8)
  • 1
    • 0020778649 scopus 로고    scopus 로고
    • Heat transfer augmentation in turbulent flow by twisted tapes at high temperature and optimum performance
    • K Watanable, T Taira and Y Mori. 'Heat Transfer Augmentation in Turbulent Flow by Twisted Tapes at High Temperature and Optimum Performance.' Heat Transfer Japanoso Research, vol 12, no 3, p 1.
    • Heat Transfer Japanoso Research , vol.12 , Issue.3 , pp. 1
    • Watanable, K.1    Taira, T.2    Mori, Y.3
  • 2
    • 0003432814 scopus 로고
    • PhD Thesis, Department of Mechanical Engineering, Aeronautical Engineering and Mechanics, Rensselaer Polytechnic Institute, Troy, New York
    • R M Manglik. 'Heat Transfer Enhancement in Tube Flow Heat Exchanger by means of Twisted Tape.' PhD Thesis, Department of Mechanical Engineering, Aeronautical Engineering and Mechanics, Rensselaer Polytechnic Institute, Troy, New York, 1991.
    • (1991) Heat Transfer Enhancement in Tube Flow Heat Exchanger by Means of Twisted Tape
    • Manglik, R.M.1
  • 3
    • 0027475845 scopus 로고
    • Heat transfer and pressure drop correlation for twisted tape insert in isothermal tube: Part II transition and turbulent flow
    • R M Manglik and Bergles. 'Heat Transfer and Pressure Drop Correlation for Twisted Tape Insert in Isothermal Tube: Part II Transition and Turbulent Flow.' ASME Journal of Heat Transfer, vol 115, 1993, P 890.
    • (1993) ASME Journal of Heat Transfer , vol.115 , pp. 890
    • Manglik, R.M.1    Bergles2
  • 5
    • 0033390524 scopus 로고    scopus 로고
    • Investigation of twisted tape inserted solar water heater-heat transfer, friction factor and thermal performance results
    • A Kumar and B N Prasad. 'Investigation of Twisted Tape Inserted Solar Water Heater-Heat Transfer, Friction Factor and Thermal Performance Results.' International Journal of Renewable Energy, vol 19, P 379.
    • International Journal of Renewable Energy , vol.19 , pp. 379
    • Kumar, A.1    Prasad, B.N.2
  • 6
    • 85004586240 scopus 로고
    • Friction and forced convection heat transfer characteristics in tubes with twisted tapes swirl generator
    • Series
    • E Smithberg, F Landies. 1964. 'Friction and Forced Convection Heat Transfer Characteristics in Tubes with Twisted Tapes Swirl Generator.' Journal of Heat transfer, Transaction of ASME 86:39-49 Series.
    • (1964) Journal of Heat Transfer, Transaction of ASME , vol.86 , pp. 39-49
    • Smithberg, E.1    Landies, F.2
  • 7
    • 84859606998 scopus 로고    scopus 로고
    • A method of testing for rating solar collector based on thermal performance
    • J E Hill and E R Streed. 'A Method of Testing for Rating Solar Collector based on Thermal Performance.' Solar Energy, vol 18, p 42.
    • Solar Energy , vol.18 , pp. 42
    • Hill, J.E.1    Streed, E.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.