메뉴 건너뛰기




Volumn 293, Issue , 2012, Pages 53-60

Productivity intensification of humidification-dehumidification desalination unit by using pulsed water flow regime

Author keywords

Desalination; Humidification dehumidification; Mass and heat transfer; Pulsed flow

Indexed keywords

AIR FLOW-RATE; AIR-WATER; DESALINATION UNITS; EXPERIMENTAL VALUES; HEAT AND MASS TRANSFER; HEAT TRANSFER UNITS; HUMIDIFICATION-DEHUMIDIFICATION; INLET COOLING; INLET WATER TEMPERATURES; LIQUID FLOW; OFF TIME; OVERALL HEAT TRANSFER COEFFICIENT; WATER FLOWS; WATER PULSATION;

EID: 84859500880     PISSN: 00119164     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.desal.2012.02.023     Document Type: Article
Times cited : (23)

References (38)
  • 1
    • 0345621592 scopus 로고    scopus 로고
    • Heat convection from a sphere placed in an oscillating free stream
    • Alasser R.S., Badr H.M., Mavromatis H.A. Heat convection from a sphere placed in an oscillating free stream. Int. J. Heat Mass Trans. 1999, 42:1289-1304.
    • (1999) Int. J. Heat Mass Trans. , vol.42 , pp. 1289-1304
    • Alasser, R.S.1    Badr, H.M.2    Mavromatis, H.A.3
  • 2
    • 0037292879 scopus 로고    scopus 로고
    • Photo-oxidation of a model pollutant in an oscillatory flow reactor with baffles
    • Gao P., Han Ching W., Herrmann M., Kwong C., Yue P.L. Photo-oxidation of a model pollutant in an oscillatory flow reactor with baffles. Chem. Eng. Sci. 2003, 58(3-6):1013-1021.
    • (2003) Chem. Eng. Sci. , vol.58 , Issue.3-6 , pp. 1013-1021
    • Gao, P.1    Han Ching, W.2    Herrmann, M.3    Kwong, C.4    Yue, P.L.5
  • 3
    • 0036641925 scopus 로고    scopus 로고
    • A comparison between mass transfer in boundary and pressure driven oscillatory flow
    • Thomas A.M., Narayanan R. A comparison between mass transfer in boundary and pressure driven oscillatory flow. Int. J. Heat Mass Trans. 2002, 45:4057-4062.
    • (2002) Int. J. Heat Mass Trans. , vol.45 , pp. 4057-4062
    • Thomas, A.M.1    Narayanan, R.2
  • 4
    • 0036601057 scopus 로고    scopus 로고
    • Mixed convection from a cylinder oscillating vertically in a quiescent fluid
    • Mahfouz F.M., Badr H.M. Mixed convection from a cylinder oscillating vertically in a quiescent fluid. Int. J. Heat Mass Trans. 2002, 38(6):477-486.
    • (2002) Int. J. Heat Mass Trans. , vol.38 , Issue.6 , pp. 477-486
    • Mahfouz, F.M.1    Badr, H.M.2
  • 5
    • 0034696413 scopus 로고    scopus 로고
    • Influence of imposed oscillatory frequency on mass transfer enhancement of grooved channels for pulsatile flow
    • Nishimura T., Oka N., Yoshinak Y., Kunitsugu K. Influence of imposed oscillatory frequency on mass transfer enhancement of grooved channels for pulsatile flow. J. Heat Mass Trans. 2000, 43:2365-2374.
    • (2000) J. Heat Mass Trans. , vol.43 , pp. 2365-2374
    • Nishimura, T.1    Oka, N.2    Yoshinak, Y.3    Kunitsugu, K.4
  • 6
    • 0038476374 scopus 로고    scopus 로고
    • Parametric instability in oscillatory shear flows
    • Poulin F.J., Flierl G.R., Pedlosky J. Parametric instability in oscillatory shear flows. J. Fluid Mech. 2003, 481:329-353.
    • (2003) J. Fluid Mech. , vol.481 , pp. 329-353
    • Poulin, F.J.1    Flierl, G.R.2    Pedlosky, J.3
  • 7
    • 0000834792 scopus 로고
    • Heat transfer to a fluid flowing periodical at low frequencies in a vertical tube
    • Artineelli M., Boeleter R.C., Weinberg L.M.K., Yakahi S.E.B. Heat transfer to a fluid flowing periodical at low frequencies in a vertical tube. Trans. Asme 1943, 789-798.
    • (1943) Trans. Asme , pp. 789-798
    • Artineelli, M.1    Boeleter, R.C.2    Weinberg, L.M.K.3    Yakahi, S.E.B.4
  • 9
    • 8344251978 scopus 로고    scopus 로고
    • Analytical study of pulsating laminar heat convection in a circular tube with constant heat flux
    • Chang J., Zhi X.Y.L., Zhaoan T.S. Analytical study of pulsating laminar heat convection in a circular tube with constant heat flux. J. Heat Mass Transf. 2004, 47:5297-5301.
    • (2004) J. Heat Mass Transf. , vol.47 , pp. 5297-5301
    • Chang, J.1    Zhi, X.Y.L.2    Zhaoan, T.S.3
  • 10
    • 33645867969 scopus 로고    scopus 로고
    • Analysis of heat transfer in simultaneously developing pulsating laminar flow in a pipe with constant wall temperature
    • Chattopadhyay H., Durst F., Ray S. Analysis of heat transfer in simultaneously developing pulsating laminar flow in a pipe with constant wall temperature. J. Heat Mass Transf. 2006, 33:475-481.
    • (2006) J. Heat Mass Transf. , vol.33 , pp. 475-481
    • Chattopadhyay, H.1    Durst, F.2    Ray, S.3
  • 11
    • 0025664573 scopus 로고
    • Numerical solutions of pulsating flow and heat transfer characteristics in a pipe
    • Cho H.W., Hyun J.M. Numerical solutions of pulsating flow and heat transfer characteristics in a pipe. Int. J. Heat fluid flow 1990, 4:321-330.
    • (1990) Int. J. Heat fluid flow , vol.4 , pp. 321-330
    • Cho, H.W.1    Hyun, J.M.2
  • 12
    • 84859479909 scopus 로고    scopus 로고
    • Numerical study of heat transfer in pulsating turbulent air flow
    • January 3-6
    • Elshafei E., Safwat M., Mansour H., Sakr M. Numerical study of heat transfer in pulsating turbulent air flow. ThETA 1. Cairo, Egypt 2007, 68. January 3-6.
    • (2007) ThETA 1. Cairo, Egypt , pp. 68
    • Elshafei, E.1    Safwat, M.2    Mansour, H.3    Sakr, M.4
  • 13
    • 0018432616 scopus 로고
    • The effect of pulsation on heat transfer
    • Erdal O.K., Gainer J.L. The effect of pulsation on heat transfer. Int. Eng. Chem. Fundam. 1979, 18(10):11-15.
    • (1979) Int. Eng. Chem. Fundam. , vol.18 , Issue.10 , pp. 11-15
    • Erdal, O.K.1    Gainer, J.L.2
  • 14
    • 10444252977 scopus 로고    scopus 로고
    • Heat transfer characteristics and Nusselt number correlation of turbulent pulsating air flows
    • Habib M.A., Attya A.M., Said S.A.M., Eid A.L., Aly A.Z. Heat transfer characteristics and Nusselt number correlation of turbulent pulsating air flows. J. Heat Mass Transf. 2004, 40:307-318.
    • (2004) J. Heat Mass Transf. , vol.40 , pp. 307-318
    • Habib, M.A.1    Attya, A.M.2    Said, S.A.M.3    Eid, A.L.4    Aly, A.Z.5
  • 15
    • 0036478889 scopus 로고    scopus 로고
    • Convective heat transfer characteristics of laminar pulsating air flow
    • Habib M.A., Attya A.M., Said S.A.M., Eid A.l., Aly A.Z. Convective heat transfer characteristics of laminar pulsating air flow. J. Heat Mass Transf. 2002, 38:221-232.
    • (2002) J. Heat Mass Transf. , vol.38 , pp. 221-232
    • Habib, M.A.1    Attya, A.M.2    Said, S.A.M.3    Eid, A.4    Aly, A.Z.5
  • 16
    • 0031195102 scopus 로고    scopus 로고
    • Analysis of the Nusselt number in pulsating pipe flow
    • Guo Z., Sung H.J. Analysis of the Nusselt number in pulsating pipe flow. J. Heat Mass Transf. 1997, 40(10):2486-2489.
    • (1997) J. Heat Mass Transf. , vol.40 , Issue.10 , pp. 2486-2489
    • Guo, Z.1    Sung, H.J.2
  • 17
    • 0018495195 scopus 로고
    • Heat transfer with laminar pulsating flow in pipe
    • Faghri M., Javdani K., Faghri A. Heat transfer with laminar pulsating flow in pipe. Lett. Heat Mass Transf. 1979, 6(4):259-270.
    • (1979) Lett. Heat Mass Transf. , vol.6 , Issue.4 , pp. 259-270
    • Faghri, M.1    Javdani, K.2    Faghri, A.3
  • 19
    • 0442312367 scopus 로고    scopus 로고
    • Mass transfer enhancement at vertically oscillating electrodes
    • Gomaa H.G., Al-Taweel A.M., Landau J. Mass transfer enhancement at vertically oscillating electrodes. Chem. Eng. J. 2003, 97:141-149.
    • (2003) Chem. Eng. J. , vol.97 , pp. 141-149
    • Gomaa, H.G.1    Al-Taweel, A.M.2    Landau, J.3
  • 20
    • 7544242276 scopus 로고    scopus 로고
    • Recovery of copper from industrial waste solution by cementation on reciprocating horizontal perforated zinc disc
    • Mubarak A.A., El-Shazly A.H., Konsowa A.H. Recovery of copper from industrial waste solution by cementation on reciprocating horizontal perforated zinc disc. Desalination 2004, 167:127-133.
    • (2004) Desalination , vol.167 , pp. 127-133
    • Mubarak, A.A.1    El-Shazly, A.H.2    Konsowa, A.H.3
  • 21
    • 33745052188 scopus 로고    scopus 로고
    • Intensification of the rate of heavy metal removal from industrial effluents by cementation on a reciprocating array of vertical parallel plates, Alex
    • El-Shazly A.H. Intensification of the rate of heavy metal removal from industrial effluents by cementation on a reciprocating array of vertical parallel plates, Alex. Eng. J. 2005, 44(5):797.
    • (2005) Eng. J. , vol.44 , Issue.5 , pp. 797
    • El-Shazly, A.H.1
  • 22
    • 79955812704 scopus 로고    scopus 로고
    • Improving the diffusion controlled cementation of cadmium ions using reciprocating fixed bed of zinc rings
    • El-Shazly A.H., Mubarak A.A., Bamufleh H.S. Improving the diffusion controlled cementation of cadmium ions using reciprocating fixed bed of zinc rings. Defect and Diffusion Forum 2011, 312-315:694-699.
    • (2011) Defect and Diffusion Forum , pp. 694-699
    • El-Shazly, A.H.1    Mubarak, A.A.2    Bamufleh, H.S.3
  • 23
    • 67049119078 scopus 로고    scopus 로고
    • Mass transfer conditions on a perforated electrode support vibrating in an electrolytic cell
    • Venkateswarlu P., Jaya Raj N., Subba Rao D., Subbaiah T. Mass transfer conditions on a perforated electrode support vibrating in an electrolytic cell. Chem Eng. Process. 2002, 41:349-356.
    • (2002) Chem Eng. Process. , vol.41 , pp. 349-356
    • Venkateswarlu, P.1    Jaya Raj, N.2    Subba Rao, D.3    Subbaiah, T.4
  • 24
    • 0032863731 scopus 로고    scopus 로고
    • Mass transport and residence time characteristics of an oscillatory flow electrochemical reactor
    • Carpenter N.G., Roberts E.P.L. Mass transport and residence time characteristics of an oscillatory flow electrochemical reactor. Trans Inst. Chem. Eng. 1999, 77(A):212-217.
    • (1999) Trans Inst. Chem. Eng. , vol.77 , Issue.A , pp. 212-217
    • Carpenter, N.G.1    Roberts, E.P.L.2
  • 25
    • 0017015656 scopus 로고
    • Comparative analysis of mass transfer at vibrating electrodes
    • Al Taweel A.M., Ismail M.I. Comparative analysis of mass transfer at vibrating electrodes. J. Appl. Electrochem. 1976, 6:559-564.
    • (1976) J. Appl. Electrochem. , vol.6 , pp. 559-564
    • Al Taweel, A.M.1    Ismail, M.I.2
  • 27
    • 0027657869 scopus 로고
    • Experimental and theoretical study of a humidification-dehumidification desalting system
    • Younis M.A., Darwish M.A., Juwayhel F. Experimental and theoretical study of a humidification-dehumidification desalting system. Desalination 1993, 94:11-24.
    • (1993) Desalination , vol.94 , pp. 11-24
    • Younis, M.A.1    Darwish, M.A.2    Juwayhel, F.3
  • 28
    • 11944268403 scopus 로고    scopus 로고
    • Experimental study of a multiple-effect humidification solar desalination technique
    • Ben-Amara M., Houcine I., Guizani A., Maalej M. Experimental study of a multiple-effect humidification solar desalination technique. Desalination 2004, 170:209-221.
    • (2004) Desalination , vol.170 , pp. 209-221
    • Ben-Amara, M.1    Houcine, I.2    Guizani, A.3    Maalej, M.4
  • 29
    • 54149091198 scopus 로고    scopus 로고
    • Experimental analysis of humidification process by air passing through seawater
    • El-Agouz S.A., Abugderah M. Experimental analysis of humidification process by air passing through seawater. Energy Convers Manage. 2008, 49(12):3698-3703.
    • (2008) Energy Convers Manage. , vol.49 , Issue.12 , pp. 3698-3703
    • El-Agouz, S.A.1    Abugderah, M.2
  • 30
    • 77954224632 scopus 로고    scopus 로고
    • Performance characteristics of a solar humidification dehumidification unit using packed bed of screens as the humidifier
    • El-Shazly A.H., El-Gohary M.M., Ossman M.E. Performance characteristics of a solar humidification dehumidification unit using packed bed of screens as the humidifier. Desalination Water Treat. J. 2010, 16:1-12.
    • (2010) Desalination Water Treat. J. , vol.16 , pp. 1-12
    • El-Shazly, A.H.1    El-Gohary, M.M.2    Ossman, M.E.3
  • 34
    • 1242310263 scopus 로고    scopus 로고
    • Solar desalination with a humidification-dehumidification technique - a comprehensive technical review
    • Parekh S., Farid M.M., Selman J.R., Al-Hallaj S. Solar desalination with a humidification-dehumidification technique - a comprehensive technical review. Desalination 2004, 160:167-186.
    • (2004) Desalination , vol.160 , pp. 167-186
    • Parekh, S.1    Farid, M.M.2    Selman, J.R.3    Al-Hallaj, S.4
  • 36
    • 79960155265 scopus 로고    scopus 로고
    • Experimental study of a solar desalination system based on humidification-dehumidification process
    • Yuan G., Wang Z., Li H., Li X. Experimental study of a solar desalination system based on humidification-dehumidification process. Desalination 2011, 277:92-98.
    • (2011) Desalination , vol.277 , pp. 92-98
    • Yuan, G.1    Wang, Z.2    Li, H.3    Li, X.4
  • 37
    • 33746316842 scopus 로고    scopus 로고
    • Solar desalination with humidification-dehumidification cycle: review of economics
    • Al-Hallaj Said, Parekh Sandeep, Farid M.M., Selman J.R. Solar desalination with humidification-dehumidification cycle: review of economics. Desalination 2006, 195:169-186.
    • (2006) Desalination , vol.195 , pp. 169-186
    • Al-Hallaj, S.1    Parekh, S.2    Farid, M.M.3    Selman, J.R.4
  • 38
    • 71849097481 scopus 로고    scopus 로고
    • Economical study of a small-scale direct contact humidification-dehumidification desalination plant
    • Eslamimanesh A., Hatamipour M.S. Economical study of a small-scale direct contact humidification-dehumidification desalination plant. Desalination 2010, 250:203-207.
    • (2010) Desalination , vol.250 , pp. 203-207
    • Eslamimanesh, A.1    Hatamipour, M.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.