메뉴 건너뛰기




Volumn 14, Issue 4, 2012, Pages 593-598

Discordant electrical and mechanical atrial delays affect intracavitary electrogram-based cardiac resynchronization therapy optimization

Author keywords

Atrioventricular delay optimization; Cardiac resynchronization therapy; QuickOpt algorithm

Indexed keywords

AGED; ALGORITHM; AORTIC FLOW VELOCITY TIME INTEGRAL; ARTICLE; CARDIAC PATIENT; CARDIAC RESYNCHRONIZATION THERAPY; CARDIOVASCULAR PARAMETERS; CARDIOVASCULAR PROCEDURES; CLINICAL ARTICLE; CONGESTIVE CARDIOMYOPATHY; DOPPLER ECHOCARDIOGRAPHY; ECHOCARDIOGRAPHY; ELECTRICAL ATRIOVENTRICULAR DELAY; ELECTROGRAPHY; FEMALE; HEART EJECTION FRACTION; HEART LEFT VENTRICLE ENDDIASTOLIC VOLUME; HEART LEFT VENTRICLE ENDSYSTOLIC VOLUME; HUMAN; ISCHEMIC CARDIOMYOPATHY; MALE; MECHANICAL ATRIOVENTRICULAR DELAY; PRIORITY JOURNAL; SAINT JUDE HEART VALVE PROSTHESIS;

EID: 84859410566     PISSN: 10995129     EISSN: 15322092     Source Type: Journal    
DOI: 10.1093/europace/eur335     Document Type: Article
Times cited : (7)

References (19)
  • 2
    • 7744241195 scopus 로고    scopus 로고
    • Randomized prospective trial of atrioventricular delay programming for cardiac resynchronization therapy
    • DOI 10.1016/j.hrthm.2004.07.006, PII S1547527104003935
    • Sawhney NS, Waggoner AD, Garhwal S, Chawla MK, Osborn J, Faddis MN. Randomized prospective trial of atrioventricular delay programming for cardiac resynchronization therapy. Heart Rhythm 2004;1:562-7. (Pubitemid 39462715)
    • (2004) Heart Rhythm , vol.1 , Issue.5 , pp. 562-567
    • Sawhney, N.S.1    Waggoner, A.D.2    Garhwal, S.3    Chawla, M.K.4    Osborn, J.5    Faddis, M.N.6
  • 3
    • 31444450241 scopus 로고    scopus 로고
    • Prospective comparison of echocardiographic atrioventricular delay optimization methods for cardiac resynchronization therapy
    • DOI 10.1016/j.hrthm.2005.11.006, PII S1547527105023404
    • Kerlan JE, Sawhney NS, Waggoner AD, Chawla MK, Garhwal S, Osborn JL et al. Prospective comparison of echocardiographic atrioventricular delay optimization methods for cardiac resynchronization therapy. Heart Rhythm 2006;3:148-54. (Pubitemid 43149986)
    • (2006) Heart Rhythm , vol.3 , Issue.2 , pp. 148-154
    • Kerlan, J.E.1    Sawhney, N.S.2    Waggoner, A.D.3    Chawla, M.K.4    Garhwal, S.5    Osborn, J.L.6    Faddis, M.N.7
  • 5
    • 60449089123 scopus 로고    scopus 로고
    • Insight from a cardiac resynchronization optimization clinic as part of a heart failure disease management program
    • Mullens W, Grimm RA, Verga T, Dresing T, Starling RC, Wilkoff BL et al. Insight from a cardiac resynchronization optimization clinic as part of a heart failure disease management program. J Am Coll Cardiol 2009;53:765-73.
    • (2009) J Am Coll Cardiol , vol.53 , pp. 765-773
    • Mullens, W.1    Grimm, R.A.2    Verga, T.3    Dresing, T.4    Starling, R.C.5    Wilkoff, B.L.6
  • 8
    • 73849122669 scopus 로고    scopus 로고
    • A prospective comparison of echocardiography and device algorithms for atrioventricular and interventricular interval optimization in cardiac resynchronization therapy
    • Kamdar R, Frain E, Warburton F, Richmond L, Mullan V, Berriman T et al. A prospective comparison of echocardiography and device algorithms for atrioventricular and interventricular interval optimization in cardiac resynchronization therapy. Europace 2010;12:84-91.
    • (2010) Europace , vol.12 , pp. 84-91
    • Kamdar, R.1    Frain, E.2    Warburton, F.3    Richmond, L.4    Mullan, V.5    Berriman, T.6
  • 9
    • 2642539260 scopus 로고    scopus 로고
    • Electrical and mechanical components of dyssynchrony in heart failure patients with normal QRS duration and left bundle-branch block: Impact of left and biventricular pacing
    • DOI 10.1161/01.CIR.0000131184.40893.40
    • Turner MS, Bleasdale RA, Vinereanu D, Mumford CE, Paul V, Fraser AG et al. Electrical and mechanical components of dyssynchrony in heart failure patients with normal QRS duration and left bundle-branch block: impact of left and biventricular pacing. Circulation 2004;109:2544-9. (Pubitemid 38720554)
    • (2004) Circulation , vol.109 , Issue.21 , pp. 2544-2549
    • Turner, M.S.1    Bleasdale, R.A.2    Vinereanu, D.3    Mumford, C.E.4    Paul, V.5    Fraser, A.G.6    Frenneaux, M.P.7
  • 11
    • 0036787663 scopus 로고    scopus 로고
    • Systolic improvement and mechanical resynchronization does not require electrical synchronyin the dilated failing heart with left bundle-branch block
    • Leclercq C, Faris O, Tunin R, Johnson J, Kato R, Evans F et al. Systolic improvement and mechanical resynchronization does not require electrical synchronyin the dilated failing heart with left bundle-branch block. Circulation 2002;106:1760-3.
    • (2002) Circulation , vol.106 , pp. 1760-1763
    • Leclercq, C.1    Faris, O.2    Tunin, R.3    Johnson, J.4    Kato, R.5    Evans, F.6
  • 12
    • 0031084948 scopus 로고    scopus 로고
    • Noninvasive doppler-derived myocardial performance index: Correlation with simultaneous measurements of cardiac catheterization measurements
    • Tei C, Nishimura RA, Seward JB, Tajik AJ. Noninvasive Doppler-derived myocardial performance index: correlation with simultaneous measurements of cardiac catheterization measurements. J Am Soc Echocardiogr 1997;10:169-78. (Pubitemid 127789844)
    • (1997) Journal of the American Society of Echocardiography , vol.10 , Issue.2 , pp. 169-178
    • Tei, C.1    Nishimura, R.A.2    Seward, J.B.3    Tajik, A.J.4
  • 13
    • 0036665057 scopus 로고    scopus 로고
    • Interatrial septum pacing avoids the adverse effect of interatrial delay in biventricular pacing: An echo-Doppler evaluation
    • DOI 10.1053/eupc.2002.0239
    • Porciani MC, Sabini A, Colella A, Michelucci A, Musilli N, Pieragnoli P et al. Interatrial septum pacing avoids the adverse effect of interatrial delay in biventricular pacing: an echo-Doppler evaluation. Europace 2002;4:317-24. (Pubitemid 36104690)
    • (2002) Europace , vol.4 , Issue.3 , pp. 317-324
    • Porciani, M.C.1    Sabini, A.2    Colella, A.3    Michelucci, A.4    Musilli, N.5    Pieragnoli, P.6    Padeletti, L.7
  • 14
    • 33846992233 scopus 로고    scopus 로고
    • Interatrial conduction measured during biventricular pacemaker implantation accurately predicts optimal paced atrioventricular intervals
    • Levin V, Nemeth M, Colombowala I, Massumi A, Rasekh A, Cheng J et al. Interatrial conduction measured during biventricular pacemaker implantation accurately predicts optimal paced atrioventricular intervals. J Cardiovasc Electrophysiol 2007;18:290-5.
    • (2007) J Cardiovasc Electrophysiol , vol.18 , pp. 290-295
    • Levin, V.1    Nemeth, M.2    Colombowala, I.3    Massumi, A.4    Rasekh, A.5    Cheng, J.6
  • 15
    • 79953783372 scopus 로고    scopus 로고
    • Interatrial conduction correlates with optimal atrioventricular timing in cardiac resynchronization therapy devices
    • Levin V, Razavi M, Coll R, Coles JA, Sambelashvili A. Interatrial conduction correlates with optimal atrioventricular timing in cardiac resynchronization therapy devices. Pacing Clin Electrophysiol 2011;34:443-9.
    • (2011) Pacing Clin Electrophysiol , vol.34 , pp. 443-449
    • Levin, V.1    Razavi, M.2    Coll, R.3    Coles, J.A.4    Sambelashvili, A.5
  • 18
  • 19
    • 33646489038 scopus 로고    scopus 로고
    • Randomized comparison of simultaneous biventricular stimulation versus optimized interventricular delay in cardiac resynchronization therapy: The Resynchronization for the Hemodynamic Treatment for Heart Failure Management II Implantable Cardioverter Defibrillator (RHYTHM II ICD) study
    • Boriani G, Muller CP, Seidl KH, Grove R, Vogt J, Danschel W et al. Randomized comparison of simultaneous biventricular stimulation versus optimized interventricular delay in cardiac resynchronization therapy: the Resynchronization for the Hemodynamic Treatment for Heart Failure Management II Implantable Cardioverter Defibrillator (RHYTHM II ICD) study. Am Heart J 2006;151:1050-8.
    • (2006) Am Heart J , vol.151 , pp. 1050-1058
    • Boriani, G.1    Muller, C.P.2    Seidl, K.H.3    Grove, R.4    Vogt, J.5    Danschel, W.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.