Patient training for functional use of pattern recognition-controlled prostheses

Author keywords

amputation; clinical protocol; multifunctional prosthesis; myoelectric control; pattern recognition; prosthesis; training; upper limb

Indexed keywords


EID: 84859377854     PISSN: 10408800     EISSN: None     Source Type: Journal    
DOI: 10.1097/JPO.0b013e3182515437     Document Type: Article
Times cited : (80)

References (19)
  • 1
    • 77951893489 scopus 로고    scopus 로고
    • Quantifying pattern recognition - Based myoelectric control of multifunctional transradial prostheses
    • Li G, Schultz AE, Kuiken TA. Quantifying pattern recognition - based myoelectric control of multifunctional transradial prostheses. IEEE Trans Neural Syst Rehabil Eng 2010;18:185-192.
    • (2010) IEEE Trans Neural Syst Rehabil Eng , vol.18 , pp. 185-192
    • Li, G.1    Schultz, A.E.2    Kuiken, T.A.3
  • 2
    • 60249084509 scopus 로고    scopus 로고
    • Targeted muscle reinnervation for real-time myoelectric control of multifunction artificial arms
    • Kuiken TA, Li G, Lock BA, et al. Targeted muscle reinnervation for real-time myoelectric control of multifunction artificial arms. JAMA 2009;301:619-628.
    • (2009) JAMA , vol.301 , pp. 619-628
    • Kuiken, T.A.1    Li, G.2    Lock, B.A.3
  • 3
    • 79960833400 scopus 로고    scopus 로고
    • Target achievement control test: Evaluating real-time myoelectric pattern-recognition control of multifunctional upper-limb prostheses
    • Simon AM, Hargrove LJ, Lock BA, Kuiken TA. Target Achievement Control Test: evaluating real-time myoelectric pattern-recognition control of multifunctional upper-limb prostheses. J Rehabil Res Dev 2011;48:619-627.
    • (2011) J Rehabil Res Dev , vol.48 , pp. 619-627
    • Simon, A.M.1    Hargrove, L.J.2    Lock, B.A.3    Kuiken, T.A.4
  • 4
    • 79960735491 scopus 로고    scopus 로고
    • A decision-based velocity ramp for minimizing the effects of misclassifications during real-time pattern recognition control
    • Simon AM, Hargrove L, Lock B, Kuiken T. A decision-based velocity ramp for minimizing the effects of misclassifications during real-time pattern recognition control. IEEE Trans Biomed Eng 2011;58:2360-2368.
    • (2011) IEEE Trans Biomed Eng , vol.58 , pp. 2360-2368
    • Simon, A.M.1    Hargrove, L.2    Lock, B.3    Kuiken, T.4
  • 6
    • 33644694014 scopus 로고    scopus 로고
    • Targeted reinnervation for improved prosthetic function
    • DOI 10.1016/j.pmr.2005.10.001, PII S1047965105000951, New Advances in Prosthetics and Orthotics
    • Kuiken T. Targeted reinnervation for improved prosthetic function. Phys Med Rehabil Clin N Am 2006;17:1-13. (Pubitemid 43330949)
    • (2006) Physical Medicine and Rehabilitation Clinics of North America , vol.17 , Issue.1 , pp. 1-13
    • Kuiken, T.1
  • 8
    • 0042889301 scopus 로고    scopus 로고
    • Continuous multifunction myoelectric control using pattern recognition
    • Englehart K, Hudgins B, Chan ADC. Continuous multifunction myoelectric control using pattern recognition. Technol Disabil 2003;15:95-103. (Pubitemid 37025179)
    • (2003) Technology and Disability , vol.15 , Issue.2 , pp. 95-103
    • Englehart, K.1    Hudgins, B.2    Chan, A.D.C.3
  • 9
    • 67649182962 scopus 로고    scopus 로고
    • Decoding of individuated finger movements using surface electromyography
    • Tenore FV, Ramos A, Fahmy A, et al. Decoding of individuated finger movements using surface electromyography. IEEE Trans Biomed Eng 2009;56:1427-1434.
    • (2009) IEEE Trans Biomed Eng , vol.56 , pp. 1427-1434
    • Tenore, F.V.1    Ramos, A.2    Fahmy, A.3
  • 10
    • 77950993720 scopus 로고    scopus 로고
    • Real-time myoelectric decoding of individual finger movements for a virtual target task
    • Smith RJ, Huberdeau D, Tenore F, Thakor NV. Real-time myoelectric decoding of individual finger movements for a virtual target task. Conf Proc IEEE Eng Med Biol Soc 2009;2009: 2376-2379.
    • (2009) Conf Proc. IEEE Eng Med Biol Soc , vol.2009 , pp. 2376-2379
    • Smith, R.J.1    Huberdeau, D.2    Tenore, F.3    Thakor, N.V.4
  • 11
    • 57649232883 scopus 로고    scopus 로고
    • A real-time pattern recognition based myoelectric control usability study implemented in a virtual environment
    • Hargrove L, Losier Y, Lock B, et al. A real-time pattern recognition based myoelectric control usability study implemented in a virtual environment. Conf Proc IEEE Eng Med Biol Soc 2007; 2007:4842-4845.
    • (2007) Conf Proc. IEEE Eng Med Biol Soc , vol.2007 , pp. 4842-4845
    • Hargrove, L.1    Losier, Y.2    Lock, B.3
  • 13
    • 78650807857 scopus 로고    scopus 로고
    • Examining the adverse effects of limb position on pattern recognition based myoelectric control
    • Scheme E, Fougner A, Stavdahl O, et al. Examining the adverse effects of limb position on pattern recognition based myoelectric control. Conf Proc IEEE Eng Med Biol Soc 2010;2010:6337-6340.
    • (2010) Conf Proc. IEEE Eng Med Biol Soc , vol.2010 , pp. 6337-6340
    • Scheme, E.1    Fougner, A.2    Stavdahl, O.3
  • 15
    • 20144366616 scopus 로고    scopus 로고
    • Assessmet of Capacity for Myoelectric Control: A new Rasch-built measure of prosthetic hand control
    • DOI 10.1080/16501970410024280
    • Hermansson LM, Fisher AG, Bernspang B, Eliasson AC. Assessment of capacity for myoelectric control: a new Rasch-built measure of prosthetic hand control. J Rehabil Med 2005;37:166-171. (Pubitemid 40775156)
    • (2005) Journal of Rehabilitation Medicine , vol.37 , Issue.3 , pp. 166-171
    • Hermansson, L.M.1    Fisher, A.G.2    Bernspang, B.3    Eliasson, A.-C.4
  • 16
    • 33749440429 scopus 로고    scopus 로고
    • Measurement of functional outcome with individuals who use upper extremity prosthetic devices: Current and future directions
    • DOI 10.1097/00008526-20060400000006, PII 0000852620060400000006
    • Wright FV. Measurement of functional outcome with individuals who use upper extremity prosthetic devices: current and future directions. J Prosthet Orthot 2006;18:46-56. (Pubitemid 44510416)
    • (2006) Journal of Prosthetics and Orthotics , vol.18 , Issue.2 , pp. 46-56
    • Wright, F.V.1
  • 17
    • 72149096782 scopus 로고    scopus 로고
    • Summary and recommendations of the academy's state of the science conference on upper limb prosthetic outcome measures
    • Miller LA, Swanson S. Summary and recommendations of the Academy's State of the Science Conference on Upper Limb Prosthetic Outcome Measures. J Prosthet Orthot 2009;21:83-89.
    • (2009) J Prosthet Orthot , vol.21 , pp. 83-89
    • Miller, L.A.1    Swanson, S.2
  • 18
    • 80052044427 scopus 로고    scopus 로고
    • The effects of electrode size and orientation on the sensitivity of myoelectric pattern recognition systems to electrode shift
    • Young AJ, Hargrove LJ, Kuiken TA. The effects of electrode size and orientation on the sensitivity of myoelectric pattern recognition systems to electrode shift. IEEE Trans Biomed Eng 2011;58:2537-2544.
    • (2011) IEEE Trans Biomed Eng , vol.58 , pp. 2537-2544
    • Young, A.J.1    Hargrove, L.J.2    Kuiken, T.A.3
  • 19


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.