메뉴 건너뛰기




Volumn 8210, Issue , 2012, Pages

Light dose verification for pleural PDT

Author keywords

Intracavitory treatment planning; Light dosimetry; Light fluence; Photodynamic therapy

Indexed keywords

DISCRETE LOCATION; DOSE VERIFICATION; FLUENCES; IR TRACKING; IS DEVELOPMENT; ISOTROPIC DETECTORS; LIGHT DISTRIBUTION; LIGHT DOSIMETRY; LIGHT FLUENCE; PHANTOM EXPERIMENT; PHANTOM STUDIES; PLEURAL CAVITY; POSITION DATA; TREATMENT PLANNING;

EID: 84859330835     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.908223     Document Type: Conference Paper
Times cited : (1)

References (8)
  • 1
    • 0028836707 scopus 로고
    • The relationship between integrating sphere and diffusion theory calculations of fluence rate at the wall of a spherical cavity
    • Star, W., The relationship between integrating sphere and diffusion theory calculations of fluence rate at the wall of a spherical cavity. Physics in Medicine and Biology, 1995. 40: p. 1-8.
    • (1995) Physics in Medicine and Biology , vol.40 , pp. 1-8
    • Star, W.1
  • 3
    • 0036917408 scopus 로고    scopus 로고
    • In vivo light dosimetry for motexafin lutetium-mediated PDT of recurrent breast cancer
    • DOI 10.1002/lsm.10115
    • Dimofte, A., et al., In vivo light dosimetry for motexafin lutetium-mediated PDT of recurrent breast cancer. Lasers in Surgery and Medicine, 2002. 31(5): p. 305-12. (Pubitemid 36008431)
    • (2002) Lasers in Surgery and Medicine , vol.31 , Issue.5 , pp. 305-312
    • Dimofte, A.1    Zhu, T.C.2    Hahn, S.M.3    Lustig, R.A.4
  • 4
    • 0001602406 scopus 로고    scopus 로고
    • Predictions and measurements of scattering and absorption over broad wavelength ranges in tissue phantoms
    • Mourant, J.R., et al., Predictions and measurements of scattering and absorption over broad wavelength ranges in tissue phantoms. Applied Optics, 1997. 36(4): p. 948-957.
    • (1997) Applied Optics , vol.36 , Issue.4 , pp. 948-957
    • Mourant, J.R.1
  • 5
    • 84966607889 scopus 로고
    • Light scattering in Intralipid-10 in the wavelength range of 400-1100 n
    • van Staveren, H.J., et al., "Light scattering in Intralipid-10 in the wavelength range of 400-1100 n. Appl. Optics, 1991. 30: p. 4507-4515.
    • (1991) Appl. Optics , vol.30 , pp. 4507-4515
    • Van Staveren, H.J.1
  • 6
    • 5644241964 scopus 로고    scopus 로고
    • In vivo determination of the absorption and scattering spectra of the human prostate during photodynamic therapy
    • Finlay, J., et al., In vivo determination of the absorption and scattering spectra of the human prostate during photodynamic therapy. Proc. SPIE, 2004. 5315: p. 132-142.
    • (2004) Proc. SPIE , vol.5315 , pp. 132-142
    • Finlay, J.1
  • 7
    • 18744382131 scopus 로고    scopus 로고
    • Determination of the distribution of light, optical properties, drug concentration, and tissue oxygenation in-vivo in human prostate during motexafin lutetium-mediated photodynamic therapy
    • DOI 10.1016/j.jphotobiol.2004.09.013, PII S1011134404001332
    • Zhu, T.C., J.C. Finlay, and S.M. Hahn, Determination of the distribution of light, optical properties, drug concentration, and tissue oxygenation in-vivo human prostate during motexafin luteium-mediated photodynamic therapy. Journals of Photochemistry and Photobiology B: Biology, 2005. 79(3): p. 231-241. (Pubitemid 40668442)
    • (2005) Journal of Photochemistry and Photobiology B: Biology , vol.79 , Issue.SPEC. ISS. , pp. 231-241
    • Zhu, T.C.1    Finlay, J.C.2    Hahn, S.M.3
  • 8
    • 79954504903 scopus 로고    scopus 로고
    • An IR navigation system for real-time treatment guidance of Pleural PDT
    • Zhu, T.C., et al., An IR navigation system for real-time treatment guidance of Pleural PDT Proc. SPIE, 2010. 7886: p. 78860L.
    • (2010) Proc. SPIE , vol.7886
    • Zhu, T.C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.