메뉴 건너뛰기




Volumn , Issue , 2010, Pages 1610-1623

Monitoring Techniques for Evaluating Suspected Sleep-Disordered Breathing

Author keywords

[No Author keywords available]

Indexed keywords


EID: 84859322125     PISSN: None     EISSN: None     Source Type: Book    
DOI: 10.1016/B978-1-4160-6645-3.00142-0     Document Type: Chapter
Times cited : (8)

References (39)
  • 1
    • 0346189950 scopus 로고    scopus 로고
    • Obstructive sleep apnea syndrome
    • Oxford University Press, New York, M.S. Aldrich (Ed.)
    • Aldrich MS Obstructive sleep apnea syndrome. Sleep medicine 1999, 202-236. Oxford University Press, New York. M.S. Aldrich (Ed.).
    • (1999) Sleep medicine , pp. 202-236
    • Aldrich, M.S.1
  • 3
    • 0032819867 scopus 로고    scopus 로고
    • Cardiogenic oscillations on the airflow signal during continuous positive airway pressure as a marker of central apnea
    • Ayappa I, Norman RG, Rapoport DM Cardiogenic oscillations on the airflow signal during continuous positive airway pressure as a marker of central apnea. Chest 1999, 116:660-666.
    • (1999) Chest , vol.116 , pp. 660-666
    • Ayappa, I.1    Norman, R.G.2    Rapoport, D.M.3
  • 5
    • 0031408629 scopus 로고    scopus 로고
    • Detection of respiratory events during NPSG: nasal cannula/pressure sensor versus thermistor
    • Norman RG, Ahmed MM, Walsleben JA, Rapoport DM, et al. Detection of respiratory events during NPSG: nasal cannula/pressure sensor versus thermistor. Sleep 1997, 20:1175-1184.
    • (1997) Sleep , vol.20 , pp. 1175-1184
    • Norman, R.G.1    Ahmed, M.M.2    Walsleben, J.A.3    Rapoport, D.M.4
  • 7
    • 0014060388 scopus 로고
    • Measurement of the separate volume changes of ribcage and abdomen during breathing
    • Konno K, Mead J Measurement of the separate volume changes of ribcage and abdomen during breathing. J Appl Physiol 1967, 22:407-422.
    • (1967) J Appl Physiol , vol.22 , pp. 407-422
    • Konno, K.1    Mead, J.2
  • 8
    • 0025608699 scopus 로고
    • A limited diagnostic investigation for obstructive sleep apnea syndrome
    • Svanborg E, Larsson H, Carlsson-Nordlander B, Pirskanen R, et al. A limited diagnostic investigation for obstructive sleep apnea syndrome. Chest 1990, 98:1341-1345.
    • (1990) Chest , vol.98 , pp. 1341-1345
    • Svanborg, E.1    Larsson, H.2    Carlsson-Nordlander, B.3    Pirskanen, R.4
  • 9
    • 84882879714 scopus 로고
    • Comparison of the stability of the respiratory inductance plethysmograph versus mercury strain gauges in measuring ventilation
    • Loveridge B, Perez-Padilla R, West P, Anthonisen NR, et al. Comparison of the stability of the respiratory inductance plethysmograph versus mercury strain gauges in measuring ventilation. Am Rev Respir Dis 1984, 129:A82.
    • (1984) Am Rev Respir Dis , vol.129
    • Loveridge, B.1    Perez-Padilla, R.2    West, P.3    Anthonisen, N.R.4
  • 10
    • 0031048386 scopus 로고    scopus 로고
    • Breathing pattern during sleep disruptive snoring
    • Bloch KE, Li Y, Sackner MA, Russi EW, et al. Breathing pattern during sleep disruptive snoring. Eur Respir J 1997, 10:576-586.
    • (1997) Eur Respir J , vol.10 , pp. 576-586
    • Bloch, K.E.1    Li, Y.2    Sackner, M.A.3    Russi, E.W.4
  • 11
    • 0031195018 scopus 로고    scopus 로고
    • Comparison of impedance and inductance ventilation sensors on adults during breathing, motion, and simulated airway obstruction
    • Cohen KP, Ladd WM, Beams DM, Sheers WS, et al. Comparison of impedance and inductance ventilation sensors on adults during breathing, motion, and simulated airway obstruction. IEEE Trans Biomed Eng 1997, 44:555-566.
    • (1997) IEEE Trans Biomed Eng , vol.44 , pp. 555-566
    • Cohen, K.P.1    Ladd, W.M.2    Beams, D.M.3    Sheers, W.S.4
  • 12
    • 4644283285 scopus 로고    scopus 로고
    • Automatic recognition of abnormal respiratory events during sleep by a pacemaker transthoracic impedance sensor
    • Defaye P, Pepin JL, Poezevara Y, Mabo P, et al. Automatic recognition of abnormal respiratory events during sleep by a pacemaker transthoracic impedance sensor. J Cardiovasc Electrophysiol 2004, 15:1034-1040.
    • (2004) J Cardiovasc Electrophysiol , vol.15 , pp. 1034-1040
    • Defaye, P.1    Pepin, J.L.2    Poezevara, Y.3    Mabo, P.4
  • 13
    • 0023938394 scopus 로고
    • The accuracy of pulse oximeters: a comparative clinical evaluation of five pulse oximeters
    • Taylor MB, Whitwam JG The accuracy of pulse oximeters: a comparative clinical evaluation of five pulse oximeters. Anaesthesia 1988, 43:229-232.
    • (1988) Anaesthesia , vol.43 , pp. 229-232
    • Taylor, M.B.1    Whitwam, J.G.2
  • 15
    • 0036433388 scopus 로고    scopus 로고
    • Oximeter performance: the influence of acquisition parameters
    • Davila DG, Richards KC, Marshall BL, O'Sullivan PS, et al. Oximeter performance: the influence of acquisition parameters. Chest 2002, 122:1654-1660.
    • (2002) Chest , vol.122 , pp. 1654-1660
    • Davila, D.G.1    Richards, K.C.2    Marshall, B.L.3    O'Sullivan, P.S.4
  • 20
    • 0019622543 scopus 로고
    • Theoretical basis of the transcutaneous blood gas measurements
    • Lubbers DW Theoretical basis of the transcutaneous blood gas measurements. Crit Care Med 1981, 9:721-733.
    • (1981) Crit Care Med , vol.9 , pp. 721-733
    • Lubbers, D.W.1
  • 21
    • 0742324113 scopus 로고    scopus 로고
    • Sleep fragmentation: clinical usefulness of autonomic markers
    • Levy P, Pepin J Sleep fragmentation: clinical usefulness of autonomic markers. Sleep Med 2003, 4:489-491.
    • (2003) Sleep Med , vol.4 , pp. 489-491
    • Levy, P.1    Pepin, J.2
  • 22
    • 0031710038 scopus 로고    scopus 로고
    • Value of beat-to-beat blood pressure changes, detected by pulse transit time, in the management of the obstructive sleep apnoea syndrome
    • Pitson DJ, Stradling JR Value of beat-to-beat blood pressure changes, detected by pulse transit time, in the management of the obstructive sleep apnoea syndrome. Eur Respir J 1998, 12:685-692.
    • (1998) Eur Respir J , vol.12 , pp. 685-692
    • Pitson, D.J.1    Stradling, J.R.2
  • 23
    • 0345040792 scopus 로고    scopus 로고
    • Differentiating obstructive and central sleep respiratory events through pulse transit time
    • Argod J, Pepin JL, Levy P Differentiating obstructive and central sleep respiratory events through pulse transit time. Am J Respir Crit Care Med 1998, 158:1778-1783.
    • (1998) Am J Respir Crit Care Med , vol.158 , pp. 1778-1783
    • Argod, J.1    Pepin, J.L.2    Levy, P.3
  • 24
    • 0026528997 scopus 로고
    • The effect of snoring on mean arterial blood pressure during non-REM sleep
    • Mateika JH, Slutsky AS, Hoffstein V The effect of snoring on mean arterial blood pressure during non-REM sleep. Am Rev Respir Dis 1992, 145:141-152.
    • (1992) Am Rev Respir Dis , vol.145 , pp. 141-152
    • Mateika, J.H.1    Slutsky, A.S.2    Hoffstein, V.3
  • 25
    • 0141446369 scopus 로고    scopus 로고
    • Assessment of a wrist-worn device in the detection of obstructive sleep apnea
    • Ayas NT, Pittman S, MacDonald M, White DP Assessment of a wrist-worn device in the detection of obstructive sleep apnea. Sleep Med 2003, 4:435-442.
    • (2003) Sleep Med , vol.4 , pp. 435-442
    • Ayas, N.T.1    Pittman, S.2    MacDonald, M.3    White, D.P.4
  • 26
    • 36849002065 scopus 로고    scopus 로고
    • Differentiating obstructive from central and complex sleep apnea using an automated electrocardiogram-based method
    • Thomas RJ, Mietus JE, Peng CK, Gilmartin G, et al. Differentiating obstructive from central and complex sleep apnea using an automated electrocardiogram-based method. Sleep 2007, 30:1756-1769.
    • (2007) Sleep , vol.30 , pp. 1756-1769
    • Thomas, R.J.1    Mietus, J.E.2    Peng, C.K.3    Gilmartin, G.4
  • 27
    • 1542434613 scopus 로고    scopus 로고
    • Practice parameters for the use of portable monitoring devices in the investigation of suspected obstructive sleep apnea in adults
    • Chesson AL, Berry RB, Pack A Practice parameters for the use of portable monitoring devices in the investigation of suspected obstructive sleep apnea in adults. Sleep 2003, 26:907-913.
    • (2003) Sleep , vol.26 , pp. 907-913
    • Chesson, A.L.1    Berry, R.B.2    Pack, A.3
  • 29
    • 0037407433 scopus 로고    scopus 로고
    • Overnight home oximetry: can it identify patients with obstructive sleep apnea-hypopnea who have minimal daytime sleepiness?
    • Hussain SF, Fleetham JA Overnight home oximetry: can it identify patients with obstructive sleep apnea-hypopnea who have minimal daytime sleepiness?. Respir Med 2003, 97:537-540.
    • (2003) Respir Med , vol.97 , pp. 537-540
    • Hussain, S.F.1    Fleetham, J.A.2
  • 30
    • 38849206434 scopus 로고    scopus 로고
    • Clinical guidelines for the use of unattended portable monitors in the diagnosis of obstructive sleep apnea in adult patients
    • Collop NA, Anderson WM, Boehlecke B, Claman D, et al. Clinical guidelines for the use of unattended portable monitors in the diagnosis of obstructive sleep apnea in adult patients. J Clin Sleep Med 2007, 3:737-747.
    • (2007) J Clin Sleep Med , vol.3 , pp. 737-747
    • Collop, N.A.1    Anderson, W.M.2    Boehlecke, B.3    Claman, D.4
  • 31
    • 0025787621 scopus 로고
    • Single night studies in obstructive sleep apnea
    • Iber C, O'Brien C, Schluter J, Davies S, et al. Single night studies in obstructive sleep apnea. Sleep 1991, 14:383-385.
    • (1991) Sleep , vol.14 , pp. 383-385
    • Iber, C.1    O'Brien, C.2    Schluter, J.3    Davies, S.4
  • 32
    • 24344495299 scopus 로고    scopus 로고
    • Experience in using split-day studies for suspected obstructive sleep apnea syndrome
    • Banno K, Al Sabbagh A, Delaive K, Higami S, et al. Experience in using split-day studies for suspected obstructive sleep apnea syndrome. Respir Med 2005, 99:1334-1339.
    • (2005) Respir Med , vol.99 , pp. 1334-1339
    • Banno, K.1    Al Sabbagh, A.2    Delaive, K.3    Higami, S.4
  • 34
    • 84906844466 scopus 로고    scopus 로고
    • Home set-up polysomnography in the assessment of suspected obstructive sleep apnea
    • [Epub ahead of print], Jun 16
    • Campbell AJ, Neill AM Home set-up polysomnography in the assessment of suspected obstructive sleep apnea. J Sleep Res 2010 Jun 16, [Epub ahead of print].
    • (2010) J Sleep Res
    • Campbell, A.J.1    Neill, A.M.2
  • 35
    • 77953935481 scopus 로고    scopus 로고
    • Validation study of portable device for the diagnosis of obstructive sleep apnea according to the new AASM scoring criteria: Watch-PAT 100
    • Choi JH, Kim EJ, Kim YS, et al. Validation study of portable device for the diagnosis of obstructive sleep apnea according to the new AASM scoring criteria: Watch-PAT 100. Acta Otolaryngol 2010, 130:838-843.
    • (2010) Acta Otolaryngol , vol.130 , pp. 838-843
    • Choi, J.H.1    Kim, E.J.2    Kim, Y.S.3
  • 36
    • 77149123313 scopus 로고    scopus 로고
    • Initial use of portable monitoring versus polysomnography to confirm obstructive sleep apnea in symptomatic patients: an economic decision model
    • Ayas NT, Fox J, Epstein L, et al. Initial use of portable monitoring versus polysomnography to confirm obstructive sleep apnea in symptomatic patients: an economic decision model. Sleep Med 2010, 11:320-324.
    • (2010) Sleep Med , vol.11 , pp. 320-324
    • Ayas, N.T.1    Fox, J.2    Epstein, L.3
  • 37
    • 84906843388 scopus 로고    scopus 로고
    • Prevalence of sleep-disordered breathing in acute ischemic stroke as determined using a portable sleep apnea monitoring device in Korean subjects
    • [Epub ahead of print], Jan 23
    • Joo BE, Seok HY, Yu SW, et al. Prevalence of sleep-disordered breathing in acute ischemic stroke as determined using a portable sleep apnea monitoring device in Korean subjects. Sleep Breath 2010 Jan 23, [Epub ahead of print].
    • (2010) Sleep Breath
    • Joo, B.E.1    Seok, H.Y.2    Yu, S.W.3
  • 38
    • 75749115614 scopus 로고    scopus 로고
    • Are sleep studies appropriately done in the home?
    • Gay PC, Selecky PA Are sleep studies appropriately done in the home?. Respir Care 2010, 55:66-75.
    • (2010) Respir Care , vol.55 , pp. 66-75
    • Gay, P.C.1    Selecky, P.A.2
  • 39
    • 77955379203 scopus 로고    scopus 로고
    • Home sleep testing: it is not about the test
    • Collop NA Home sleep testing: it is not about the test. Chest 2010, 138:245-246.
    • (2010) Chest , vol.138 , pp. 245-246
    • Collop, N.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.