메뉴 건너뛰기




Volumn 67, Issue 4, 2012, Pages 991-1003

Investigations of the origin of phase differences seen with ultrashort TE imaging of short T2 meniscal tissue

Author keywords

meniscus; phase imaging; ultrashort echo time

Indexed keywords

MUSCULOSKELETAL SYSTEM;

EID: 84859111251     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.23075     Document Type: Article
Times cited : (28)

References (24)
  • 2
    • 0025876984 scopus 로고
    • Lung parenchyma: Projection reconstruction MR imaging
    • Bergin, CJ, Pauly JM, Macovski A,. Lung parenchyma: projection reconstruction MR imaging. Radiology 1991; 179: 777-781.
    • (1991) Radiology , vol.179 , pp. 777-781
    • Bergin, C.J.1    Pauly, J.M.2    MacOvski, A.3
  • 3
    • 0028829261 scopus 로고
    • MR spectroscopic imaging of collagen: Tendons and knee menisci
    • Gold GE, Pauly JM, Macovski A, Herfkens RJ,. MR spectroscopic imaging of collagen: tendons and knee menisci. Magn Reson Med 1995; 34: 647-654.
    • (1995) Magn Reson Med , vol.34 , pp. 647-654
    • Gold, G.E.1    Pauly, J.M.2    MacOvski, A.3    Herfkens, R.J.4
  • 4
    • 0037236412 scopus 로고    scopus 로고
    • 2 components in tissue
    • DOI 10.1053/crad.2003.1157
    • Gatehouse PD, Bydder GM,. Magnetic resonance imaging of short T2 components in tissue. Clin Radiol 2003; 58: 1-19. (Pubitemid 36104938)
    • (2003) Clinical Radiology , vol.58 , Issue.1 , pp. 1-19
    • Gatehouse, P.D.1    Bydder, G.M.2
  • 5
    • 33646447508 scopus 로고    scopus 로고
    • Three-dimensional radial ultrashort echo-time imaging with T2 adapted sampling
    • Rahmer J, Bornert P, Groen J, Bos C,. Three-dimensional radial ultrashort echo-time imaging with T2 adapted sampling. Magn Reson Med 2006; 55: 1075-1082.
    • (2006) Magn Reson Med , vol.55 , pp. 1075-1082
    • Rahmer, J.1    Bornert, P.2    Groen, J.3    Bos, C.4
  • 11
    • 0031980603 scopus 로고    scopus 로고
    • Collagenous fibril texture of the human knee joint menisci
    • DOI 10.1007/s004290050141
    • Petersen W, Tillmann B,. Collagenous fibril texture of the human knee joint meniscus. Anat Embryol 1998; 197: 317-324. (Pubitemid 28156109)
    • (1998) Anatomy and Embryology , vol.197 , Issue.4 , pp. 317-324
    • Petersen, W.1    Tillmann, B.2
  • 18
    • 0033982320 scopus 로고    scopus 로고
    • Automatic field map generation and off-resonance correction for projection reconstruction imaging
    • DOI 10.1002/(SICI)1522-2594(200001)43:1<151::AID-MRM19>3.0.CO;2-K
    • Nayak KS, Nishimura DG,. Automatic field map generation and off-resonance correction for projection reconstruction imaging. Magn Reson Med 2000; 43: 151-154. (Pubitemid 30027124)
    • (2000) Magnetic Resonance in Medicine , vol.43 , Issue.1 , pp. 151-154
    • Nayak, K.S.1    Nishimura, D.G.2
  • 20
    • 0025938956 scopus 로고
    • FID-acquired-echos (FAcE) a short echo time imaging method for flow artefact suppression
    • Scheidegger MB, Maier SE, Boesiger P,. FID-acquired-echos (FAcE) a short echo time imaging method for flow artefact suppression. Magn Reson Imaging 1991; 9: 517-524.
    • (1991) Magn Reson Imaging , vol.9 , pp. 517-524
    • Scheidegger, M.B.1    Maier, S.E.2    Boesiger, P.3
  • 22
    • 0025361232 scopus 로고
    • Bulk magnetic susceptibility shifts in NMR studies of compartmentalized samples: Use of paramagnetic reagents
    • Chu SCK, Xu, Y, Balschi JA, Springer CS,. Bulk magnetic susceptibility shifts in NMR studies of compartmentalized samples: use of paramagnetic reagents. Magn Reson Med 1990; 13: 239-262. (Pubitemid 20110031)
    • (1990) Magnetic Resonance in Medicine , vol.13 , Issue.2 , pp. 239-262
    • Chu, S.C.-K.1    Xu, Y.2    Balschi, J.A.3    Springer Jr., C.S.4
  • 23
    • 0023194166 scopus 로고
    • The effects of finite sampling in spin-echo or field-echo magnetic resonance imaging
    • Haacke EM,. The effects of finite sampling in spin-echo or field-echo magnetic resonance imaging. Magn Reson Med 1987; 4: 407-421. (Pubitemid 17108566)
    • (1987) Magnetic Resonance in Medicine , vol.4 , Issue.5 , pp. 407-421
    • Haacke, E.M.1
  • 24
    • 0037342640 scopus 로고    scopus 로고
    • Magnetic susceptibility quantitation with MRI by solving boundary value problems
    • Li L, Wang ZJ,. Magnetic susceptibility quantitation with MRI by solving boundary value problems. Med Phys 2003; 30: 449.
    • (2003) Med Phys , vol.30 , pp. 449
    • Li, L.1    Wang, Z.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.