-
1
-
-
0003964363
-
-
American Cancer Society. Atlanta: American Cancer Society.
-
American Cancer Society. Cancer Facts & Figures 2010. Atlanta: American Cancer Society; 2010.
-
(2010)
Cancer Facts & Figures 2010
-
-
-
2
-
-
0002533192
-
Cancer of the prostate: An analysis of some important contributions and dilemmas
-
Stamey TA,. Cancer of the prostate: an analysis of some important contributions and dilemmas. Monogr Urol 1982; 3: 67-94.
-
(1982)
Monogr Urol
, vol.3
, pp. 67-94
-
-
Stamey, T.A.1
-
3
-
-
0028113557
-
Carcinoma of the prostate gland: MR imaging with pelvic phased-array coils versus integrated endorectal-pelvic phased-array coils
-
Hricak H, White S, Vigneron D, Kurhanewicz J, Kosco A, Levin D, Weiss J, Narayan P, Carroll PR,. Carcinoma of the prostate gland: MR imaging with pelvic phased-array coils versus integrated endorectal-pelvic phased-array coils. Radiology 1994; 193: 703-709. (Pubitemid 24366938)
-
(1994)
Radiology
, vol.193
, Issue.3
, pp. 703-709
-
-
Hricak, H.1
White, S.2
Vigneron, D.3
Kurhanewicz, J.4
Kosco, A.5
Levin, D.6
Weiss, J.7
Narayan, P.8
Carroll, P.R.9
-
4
-
-
0032757964
-
Prostate cancer: Localization with three-dimensional proton MR spectroscopic imaging - Clinicopathologic study
-
Scheidler J, Hricak H, Vigneron DB, Yu KK, Sokolov DL, Huang LR, Zaloudek CJ, Nelson SJ, Carroll PR, Kurhanewicz J,. Prostate cancer: localization with three-dimensional proton MR spectroscopic imaging-clinicopathologic study. Radiology 1999; 213: 473-480. (Pubitemid 29510595)
-
(1999)
Radiology
, vol.213
, Issue.2
, pp. 473-480
-
-
Scheidler, J.1
Hricak, H.2
Vigneron, D.B.3
Yu, K.K.4
Sokolov, D.L.5
Huang, L.R.6
Zaloudek, C.J.7
Nelson, S.J.8
Carroll, P.R.9
Kurhanewicz, J.10
-
5
-
-
0033912355
-
Sextant localization of prostate cancer: Comparison of sextant biopsy, magnetic resonance imaging and magnetic resonance spectroscopic imaging with step section histology
-
Wefer AE, Hricak H, Vigneron DB, Coakley FV, Lu Y, Wefer J, Mueller-Lisse U, Carroll PR, Kurhanewicz J,. Sextant localization of prostate cancer: comparison of sextant biopsy, magnetic resonance imaging and magnetic resonance spectroscopic imaging with step section histology. J Urol 2000; 164: 400-404. (Pubitemid 30481935)
-
(2000)
Journal of Urology
, vol.164
, Issue.2
, pp. 400-404
-
-
Wefer, A.E.1
Hricak, H.2
Vigneron, D.B.3
Coakley, F.V.4
Lu, Y.5
Wefer, J.6
Mueller-Lisse, U.7
Carroll, P.R.8
Kurhanewicz, J.9
-
6
-
-
0031052931
-
Detection of extracapsular extension of prostate carcinoma with endorectal and phased-array coil MR imaging: Multivariate feature analysis
-
Yu KK, Hricak H, Alagappan R, Chernoff DM, Bacchetti P, Zaloudek CJ,. Detection of extracapsular extension of prostate carcinoma with endorectal and phased-array coil MR imaging: multivariate feature analysis. Radiology 1997; 202: 697-702. (Pubitemid 27093440)
-
(1997)
Radiology
, vol.202
, Issue.3
, pp. 697-702
-
-
Yu, K.K.1
Hricak, H.2
Alagappan, R.3
Chernoff, D.M.4
Bacchetti, P.5
Zaloudek, C.J.6
-
7
-
-
0036794336
-
Combined magnetic resonance imaging and spectroscopic imaging approach to molecular imaging of prostate cancer
-
DOI 10.1002/jmri.10172
-
Kurhanewicz J, Swanson MG, Nelson SJ, Vigneron DB,. Combined magnetic resonance imaging and spectroscopic imaging approach to molecular imaging of prostate cancer. J Magn Reson Imaging 2002; 16: 451-463. (Pubitemid 35167879)
-
(2002)
Journal of Magnetic Resonance Imaging
, vol.16
, Issue.4
, pp. 451-463
-
-
Kurhanewicz, J.1
Swanson, M.G.2
Nelson, S.J.3
Vigneron, D.B.4
-
8
-
-
80053087603
-
Prostate cancer: Multiparametric MR imaging for detection, localization, and staging
-
Hoeks CMA, Barentsz JO, Hambrock T, Yakar D, Somford DM, Heijmink SWTPJ, Scheenen TWJ, Vos PC, Huisman H, van Oort IM, Witjes JA, Heerschap A, Fütterer JJ,. Prostate cancer: multiparametric MR imaging for detection, localization, and staging. Radiology 2011; 261: 46-66.
-
(2011)
Radiology
, vol.261
, pp. 46-66
-
-
Hoeks, C.M.A.1
Barentsz, J.O.2
Hambrock, T.3
Yakar, D.4
Somford, D.M.5
Heijmink, S.6
Scheenen, T.W.J.7
Vos, P.C.8
Huisman, H.9
Van Oort, I.M.10
Witjes, J.A.11
Heerschap, A.12
Fütterer, J.J.13
-
9
-
-
34249309938
-
MRI contrast agents: Current status and future perspectives
-
Strijkers GJ, Mulder WJ, van Tilborg GA, Nicolay K,. MRI contrast agents: current status and future perspectives. Anticancer Agents Med Chem 2007; 7: 291-305. (Pubitemid 46813466)
-
(2007)
Anti-Cancer Agents in Medicinal Chemistry
, vol.7
, Issue.3
, pp. 291-305
-
-
Strijkers, G.J.1
Mulder, W.J.M.2
Van Tilborg, G.A.F.3
Nicolay, K.4
-
10
-
-
33750527958
-
Dynamic Contrast Enhanced, Pelvic Phased Array Magnetic Resonance Imaging of Localized Prostate Cancer for Predicting Tumor Volume: Correlation With Radical Prostatectomy Findings
-
DOI 10.1016/j.juro.2006.08.007, PII S0022534706019756
-
Villers A, Puech P, Mouton D, Leroy X, Ballereau C, Lemaitre L,. Dynamic contrast enhanced, pelvic phased array magnetic resonance imaging of localized prostate cancer for predicting tumor volume: correlation with radical prostatectomy findings. J Urol 2006; 176: 2432-2437. (Pubitemid 44665992)
-
(2006)
Journal of Urology
, vol.176
, Issue.6
, pp. 2432-2437
-
-
Villers, A.1
Puech, P.2
Mouton, D.3
Leroy, X.4
Ballereau, C.5
Lemaitre, L.6
-
11
-
-
33750317870
-
Prostate cancer localization with dynamic contrast-enhanced MR imaging and proton MR spectroscopic imaging
-
DOI 10.1148/radiol.2412051866
-
Fütterer JJ, Heijmink SWTPJ, Scheenen TWJ, Veltman J, Huisman HJ, Vos P, Hulsbergen-Van de Kaa CA, Witjes JA, Krabbe PF, Heerschap A, Barentsz JO,. Prostate cancer localization with dynamic contrast-enhanced MR imaging and proton MR spectroscopic imaging. Radiology 2006; 241: 449-458. (Pubitemid 44632891)
-
(2006)
Radiology
, vol.241
, Issue.2
, pp. 449-458
-
-
Futterer, J.J.1
Heijmink, S.W.T.P.J.2
Scheenen, T.W.J.3
Veltman, J.4
Huisman, H.J.5
Vos, P.6
Hulsbergen-Van De Kaa, C.A.7
Witjes, J.A.8
Krabbe, P.F.M.9
Heerschap, A.10
Barentsz, J.O.11
-
12
-
-
33750609192
-
How Good is MRI at Detecting and Characterising Cancer within the Prostate?
-
DOI 10.1016/j.eururo.2006.06.025, PII S0302283806007421
-
Kirkham APS, Emberton M, Allen C,. How good is MRI at detecting and characterising cancer within the prostate? Eur Urol 2006; 50: 1163-1175. (Pubitemid 44692933)
-
(2006)
European Urology
, vol.50
, Issue.6
, pp. 1163-1175
-
-
Kirkham, A.P.S.1
Emberton, M.2
Allen, C.3
-
13
-
-
0002656740
-
Relaxometry of tissue
-
Gupta R.K. editor. Boca Raton, Florida: CRC Press.
-
Koenig SH, Brown RD III,. Relaxometry of tissue. In:, Gupta RK, editor. NMR spectroscopy of cells and organisms, Volume II. Boca Raton, Florida: CRC Press; 1987.
-
(1987)
NMR Spectroscopy of Cells and Organisms
, vol.2
-
-
Koenig, S.H.1
Brown Iii, R.D.2
-
14
-
-
0037155596
-
Liquid-state NMR and scalar couplings in microtesla magnetic fields
-
DOI 10.1126/science.1069280
-
McDermott R, Trabesinger AH, Mueck M, Hahn EL, Pines A, Clarke J,. Liquid-state NMR and scalar couplings in microtesla magnetic fields. Science 2002; 295: 2247-2249. (Pubitemid 34258834)
-
(2002)
Science
, vol.295
, Issue.5563
, pp. 2247-2249
-
-
McDermott, R.1
Trabesinger, A.H.2
Muck, M.3
Hahn, E.L.4
Pines, A.5
Clarke, J.6
-
15
-
-
2542641658
-
Microtesla MRI with a superconducting quantum interference device
-
DOI 10.1073/pnas.0402382101
-
McDermott R, Lee S, ten Haken B, Trabesinger AH, Pines A, Clarke J,. Microtesla MRI with a superconducting quantum interference device. Proc Natl Acad Sci U S A 2004; 101: 7857-7861. (Pubitemid 38698018)
-
(2004)
Proceedings of the National Academy of Sciences of the United States of America
, vol.101
, Issue.21
, pp. 7857-7861
-
-
McDermott, R.1
Lee, S.2
Ten Haken, B.3
Trabesinger, A.H.4
Pines, A.5
Clarke, J.6
-
16
-
-
35348825462
-
SQUID-detected magnetic resonance imaging in microtesla fields
-
DOI 10.1146/annurev.bioeng.9.060906.152010
-
Clarke J, Hatridge M, MöÃle M,. SQUID-detected magnetic resonance imaging in microtesla fields. Annu Rev Biomed Eng 2007; 9: 389-413. (Pubitemid 350246662)
-
(2007)
Annual Review of Biomedical Engineering
, vol.9
, pp. 389-413
-
-
Clarke, J.1
Hatridge, M.2
Mossle, M.3
-
18
-
-
0001554044
-
Free nuclear induction in the Earth's magnetic field
-
Packard M, Varian R,. Free nuclear induction in the Earth's magnetic field. Phys Rev 1954; 93: 941.
-
(1954)
Phys Rev
, vol.93
, pp. 941
-
-
Packard, M.1
Varian, R.2
-
19
-
-
31444437341
-
J-coupling nuclear magnetic resonance spectroscopy of liquids in nT fields
-
DOI 10.1021/ja055273e
-
Bernarding J, Buntkowsky G, Macholl S, Hartwig S, Burghoff M, Trahms L,. J-coupling nuclear magnetic resonance spectroscopy of liquids in nT fields. J Am Chem Soc 2006; 128: 714-715. (Pubitemid 43153012)
-
(2006)
Journal of the American Chemical Society
, vol.128
, Issue.3
, pp. 714-715
-
-
Bernarding, J.1
Buntkowsky, G.2
Macholl, S.3
Hartwig, S.4
Burghoff, M.5
Trahms, L.6
-
20
-
-
34548022858
-
Nuclear magnetic resonance in the earth's magnetic field using a nitrogen-cooled superconducting quantum interference device
-
Qiu L, Zhang Y, Krause HJ, Braginski AI, Burghoff M, Trahms L,. Nuclear magnetic resonance in the earth's magnetic field using a nitrogen-cooled superconducting quantum interference device. Appl Phys Lett 2007; 91: 072505.
-
(2007)
Appl Phys Lett
, vol.91
, pp. 072505
-
-
Qiu, L.1
Zhang, Y.2
Krause, H.J.3
Braginski, A.I.4
Burghoff, M.5
Trahms, L.6
-
21
-
-
22044436931
-
SQUID-detected in vivo MRI at microtesla magnetic fields
-
DOI 10.1109/TASC.2005.850043
-
MöÃle M, Myers WR, Lee SK, Kelso N, Hatridge M, Pines A, Clarke J,. SQUID-detected in vivo MRI at microtesla magnetic fields. IEEE Trans Appl Supercond 2005; 15: 757-760. (Pubitemid 40964458)
-
(2005)
IEEE Transactions on Applied Superconductivity
, vol.15
, Issue.PART I
, pp. 757-760
-
-
Mossle, M.1
Myers, W.R.2
Lee, S.-K.3
Kelso, N.4
Hatridge, M.5
Pines, A.6
Clarke, J.7
-
22
-
-
49349097516
-
Microtesla MRI of the human brain combined with MEG
-
Zotev VS, Matlashov AN, Volegov PL, Savukov IM, Espy MA, Mosher JC, Gomez JJ, Kraus RH,. Microtesla MRI of the human brain combined with MEG. J Magn Reson 2008; 194: 115-120.
-
(2008)
J Magn Reson
, vol.194
, pp. 115-120
-
-
Zotev, V.S.1
Matlashov, A.N.2
Volegov, P.L.3
Savukov, I.M.4
Espy, M.A.5
Mosher, J.C.6
Gomez, J.J.7
Kraus, R.H.8
-
23
-
-
33645867093
-
SQUID-detected microtesla MRI in the presence of metal
-
MöÃle M, Han SI, Myers WR, Lee SK, Kelso N, Hatridge M, Pines A, Clarke J,. SQUID-detected microtesla MRI in the presence of metal. J Magn Reson 2006; 179: 146-151.
-
(2006)
J Magn Reson
, vol.179
, pp. 146-151
-
-
Möãle, M.1
Han, S.I.2
Myers, W.R.3
Lee, S.K.4
Kelso, N.5
Hatridge, M.6
Pines, A.7
Clarke, J.8
-
24
-
-
33745699917
-
Prepolarized magnetic resonance imaging around metal orthopedic implants
-
Venook RD, Matter NI, Ramachandran M, Ungersma SE, Gold GE, Giori NJ, Macovski A, Scott GC, Conolly SM,. Prepolarized magnetic resonance imaging around metal orthopedic implants. Magn Reson Med 2006; 56: 177-186.
-
(2006)
Magn Reson Med
, vol.56
, pp. 177-186
-
-
Venook, R.D.1
Matter, N.I.2
Ramachandran, M.3
Ungersma, S.E.4
Gold, G.E.5
Giori, N.J.6
MacOvski, A.7
Scott, G.C.8
Conolly, S.M.9
-
25
-
-
2942563757
-
SQUID-detected magnetic resonance imaging in microtesla magnetic fields
-
DOI 10.1023/B:JOLT.0000029519.09286.c5
-
McDermott R, Kelso N, Lee SK, MöÃle M, Mueck M, Myers W, ten Haken B, Seton HC, Trabesinger AH, Pines A, Clarke J,. SQUID-detected magnetic resonance imaging in microtesla magnetic fields. J Low Temp Phys 2004; 135: 793-821. (Pubitemid 38762575)
-
(2004)
Journal of Low Temperature Physics
, vol.135
, Issue.5-6
, pp. 793-821
-
-
McDermott, R.1
Kelso, N.2
Lee, S.-K.3
Mossle, M.4
Muck, M.5
Myers, W.6
Ten Haken, B.7
Seton, H.C.8
Trabesinger, A.H.9
Pines, A.10
Clarke, J.11
-
26
-
-
15844389107
-
Liquid helium cryostat for SQUID-based MRI receivers
-
DOI 10.1016/j.cryogenics.2004.11.011, PII S001122750500010X
-
Seton HC, Hutchison JMS, Bussell DM,. Liquid helium cryostat for SQUID-based MRI receivers. Cryogenics 2005; 45: 348-355. (Pubitemid 40423382)
-
(2005)
Cryogenics
, vol.45
, Issue.5
, pp. 348-355
-
-
Seton, H.C.1
Hutchison, J.M.S.2
Bussell, D.M.3
-
28
-
-
84859105986
-
Histologic grading and staging of prostatic carcinoma
-
Gleason DF,. Histologic grading and staging of prostatic carcinoma. Am J Surg Pathol 1981; 5: 193.
-
(1981)
Am J Surg Pathol
, vol.5
, pp. 193
-
-
Gleason, D.F.1
-
29
-
-
12144268370
-
1-weighted contrast established at 10 μT-300 mT
-
DOI 10.1002/mrm.20316
-
Lee SK, MöÃle M, Myers W, Kelso N, Trabesinger AH, Pines A, Clarke J,. SQUID-detected MRI at 132 μT with T1-weighted contrast established at 10 μT-300 mT. Magn Reson Med 2005; 53: 9-14. (Pubitemid 40110471)
-
(2005)
Magnetic Resonance in Medicine
, vol.53
, Issue.1
, pp. 9-14
-
-
Seung, K.L.1
Mossle, M.2
Myers, W.3
Kelso, N.4
Trabesinger, A.H.5
Pines, A.6
Clarke, J.7
|