메뉴 건너뛰기




Volumn 27, Issue 4, 2012, Pages 313-325

Cortical bone drilling and thermal osteonecrosis

Author keywords

Bone; Drill; Drilling; Parameters; Temperature; Thermal osteonecrosis

Indexed keywords

BONE DRILLING; BONE SURGERY; CLINICAL STUDY; CORTICAL BONE; CORTICAL THICKNESS; DRILL GEOMETRY; DRILL POINT; DRILLING PARAMETERS; DRILLING SPEED; EXPERIMENTAL METHODS; EXPERIMENTAL SETUP; FEED-RATES; FRACTURE TREATMENT; FUTURE TECHNOLOGIES; IMPLANT FAILURES; OSTEONECROSIS; PARAMETERS; PATHOPHYSIOLOGY; RECONSTRUCTIVE SURGERY;

EID: 84859107029     PISSN: 02680033     EISSN: 18791271     Source Type: Journal    
DOI: 10.1016/j.clinbiomech.2011.10.010     Document Type: Review
Times cited : (322)

References (104)
  • 3
    • 0031763862 scopus 로고    scopus 로고
    • Interspecies differences in bone composition, density, and quality: Potential implications for in vivo bone research
    • DOI 10.1210/en.139.2.663
    • J. Aerssens, S. Boonen, G. Lowet, and J. Dequeker Interspecies differences in bone composition, density and quality: potential implications for in vivo bone Endocrinology 139 1998 663 670 (Pubitemid 28513217)
    • (1998) Endocrinology , vol.139 , Issue.2 , pp. 663-670
    • Aerssens, J.1    Boonen, S.2    Lowet, G.3    Dequeker, J.4
  • 4
    • 79956279436 scopus 로고    scopus 로고
    • Measurements of surface roughness in conventional and ultrasonically assisted bone drilling
    • K. Alam, A.V. Mitrofanov, and V.V. Silberschmidt Measurements of surface roughness in conventional and ultrasonically assisted bone drilling Am. J. Biomed. Sci. 1 2009 312 320
    • (2009) Am. J. Biomed. Sci. , vol.1 , pp. 312-320
    • Alam, K.1    Mitrofanov, A.V.2    Silberschmidt, V.V.3
  • 5
    • 21344469080 scopus 로고    scopus 로고
    • Effects of repeated drill use on temperature of bone during preparation for osteosynthesis self-tapping screws
    • DOI 10.1016/j.bjoms.2004.11.007, PII S026643560400230X
    • W. Allan, E.D. Williams, and C.J. Kerawala Effects of repeated drill use on temperature of bone during preparation for osteosynthesis self-tapping screws Br. J. Oral Maxillofac. Surg. 43 2005 314 319 (Pubitemid 40903781)
    • (2005) British Journal of Oral and Maxillofacial Surgery , vol.43 , Issue.4 , pp. 314-319
    • Allan, W.1    Williams, E.D.2    Kerawala, C.J.3
  • 6
    • 0040690526 scopus 로고
    • Sequele of transfixation of bone
    • R. Anderson, and B.L. Finlayson Sequele of transfixation of bone Surgery 13 1943 46 54
    • (1943) Surgery , vol.13 , pp. 46-54
    • Anderson, R.1    Finlayson, B.L.2
  • 7
    • 15944379680 scopus 로고
    • Preliminary investigation of the temperature produced in Burring
    • D. Anderson, and G. Van Proagh Preliminary investigation of the temperature produced in Burring Br. Dent. J. 73 1942 62 68
    • (1942) Br. Dent. J. , vol.73 , pp. 62-68
    • Anderson, D.1    Van Proagh, G.2
  • 8
    • 33746363257 scopus 로고    scopus 로고
    • Machining stability in high-speed drilling-Part 1: Modeling vibration stability in bending
    • DOI 10.1016/j.ijmachtools.2005.09.018, PII S0890695505002567
    • T. Arvajeh, and F. Ismail Machining stability in high-speed drilling-part 1: modeling vibration stability in bending Int. J. Mach. Tool Manuf. 46 2006 1563 1572 (Pubitemid 44119131)
    • (2006) International Journal of Machine Tools and Manufacture , vol.46 , Issue.12-13 , pp. 1563-1572
    • Arvajeh, T.1    Ismail, F.2
  • 10
    • 64449084841 scopus 로고    scopus 로고
    • Determination of spatial distribution of increase in bone temperature during drilling by infrared thermography: Preliminary report
    • G. Augustin, S. Davila, T. Udiljak, D.S. Vedrina, and D. Bagatin Determination of spatial distribution of increase in bone temperature during drilling by infrared thermography: preliminary report Arch. Orthop. Trauma Surg. 129 2009 703 709
    • (2009) Arch. Orthop. Trauma Surg. , vol.129 , pp. 703-709
    • Augustin, G.1    Davila, S.2    Udiljak, T.3    Vedrina, D.S.4    Bagatin, D.5
  • 11
    • 0034446654 scopus 로고    scopus 로고
    • The effects of drilling force on cortical temperatures and their duration: An in vitro study
    • DOI 10.1016/S1350-4533(01)00016-9, PII S1350453301000169
    • K.N. Bachus, M.T. Rondina, and D.T. Hutchinson The effects of drilling force on cortical temperatures and theirduration: an in vitro study Med. Eng. Phys. 22 2000 685 691 (Pubitemid 32378730)
    • (2000) Medical Engineering and Physics , vol.22 , Issue.10 , pp. 685-691
    • Bachus, K.N.1    Rondina, M.T.2    Hutchinson, D.T.3
  • 12
    • 28544444196 scopus 로고    scopus 로고
    • Bone resorption
    • F. Bronner, M.C. Farach-Carson, J. Rubin, Springer London
    • R. Baron, and W.C. Horne Bone resorption F. Bronner, M.C. Farach-Carson, J. Rubin, Topics in Bone Biology 2005 Springer London
    • (2005) Topics in Bone Biology
    • Baron, R.1    Horne, W.C.2
  • 15
  • 16
    • 44949141950 scopus 로고    scopus 로고
    • 3-Fluted orthopaedic drills exhibit superior bending stiffness to their 2-fluted rivals: Clinical implications for targeting ability and the incidence of drill-bit failure
    • N. Bertollo, T.K. Gothelf, and W.R. Walsh 3-Fluted orthopaedic drills exhibit superior bending stiffness to their 2-fluted rivals: clinical implications for targeting ability and the incidence of drill-bit failure Injury 39 2008 734 741
    • (2008) Injury , vol.39 , pp. 734-741
    • Bertollo, N.1    Gothelf, T.K.2    Walsh, W.R.3
  • 17
    • 77952550747 scopus 로고    scopus 로고
    • A comparison of the thermal properties of 2- and 3-fluted drills and the effects on bone cell viability and screw pull-out strength in an ovine model
    • N. Bertollo, H.R.M. Milne, L.P. Ellis, P.C. Stephens, R.M. Gillies, and W.R. Walsh A comparison of the thermal properties of 2- and 3-fluted drills and the effects on bone cell viability and screw pull-out strength in an ovine model Clin. Biomech. 25 2010 613 617
    • (2010) Clin. Biomech. , vol.25 , pp. 613-617
    • Bertollo, N.1    Milne, H.R.M.2    Ellis, L.P.3    Stephens, P.C.4    Gillies, R.M.5    Walsh, W.R.6
  • 19
    • 2942735556 scopus 로고    scopus 로고
    • Bilateral femoral head osteonecrosis after septic shock and multiorgan failure
    • DOI 10.1359/JBMR.0301250
    • M.J. Bolland, G. Hood, S.T. Bastin, A.R. King, and A. Grey Bilateral femoral head osteonecrosis after septic shock and multiorgan failure J. Bone Miner. Res. 3 2004 517 520 (Pubitemid 38787408)
    • (2004) Journal of Bone and Mineral Research , vol.19 , Issue.3 , pp. 517-520
    • Bolland, M.J.1    Hood, G.2    Bastin, S.T.3    King, A.R.4    Grey, A.5
  • 20
    • 0000659796 scopus 로고
    • The temperature dependence of the deformation of bone
    • W. Bonfield, and C.H. Li The temperature dependence of the deformation of bone J. Biomech. 1 1968 323 329
    • (1968) J. Biomech. , vol.1 , pp. 323-329
    • Bonfield, W.1    Li, C.H.2
  • 21
    • 0013888095 scopus 로고
    • Histologic response of bone to sectioning by high-speed rotary instruments
    • P.J. Boyne Histologic response of bone to sectioning by high-speed rotary instruments J. Dent. Res. 45 1966 270 276
    • (1966) J. Dent. Res. , vol.45 , pp. 270-276
    • Boyne, P.J.1
  • 22
    • 0020823258 scopus 로고
    • Osseointegration and its experimental background
    • P.I. Branemark Osseointegration and its experimental background J. Prosthet. Dent. 50 1983 399 410
    • (1983) J. Prosthet. Dent. , vol.50 , pp. 399-410
    • Branemark, P.I.1
  • 23
    • 0029683215 scopus 로고    scopus 로고
    • The Effect of Speed, Pressure, and Time on Bone Temperature during the Drilling of Implant Sites
    • D.L. Brisman The effect of speed, pressure, and time on bone temperature during the drilling of implant sites Int. J. Oral Maxillofac. Implants 11 1996 35 37 (Pubitemid 126442751)
    • (1996) International Journal of Oral and Maxillofacial Implants , vol.11 , Issue.1 , pp. 35-37
    • Brisman, D.L.1
  • 26
    • 30644469370 scopus 로고    scopus 로고
    • Heat production by 3 implant drill systems after repeated drilling and sterilization
    • DOI 10.1016/j.joms.2005.10.011, PII S0278239105016836
    • G.E. Chacon, D.L. Bower, P.E. Larsen, E.A. McGlumphy, and F.M. Beck Heat production by 3 implant drill systems after repeated drilling and sterilization J. Oral Maxillofac. Surg. 64 2006 265 269 (Pubitemid 43087788)
    • (2006) Journal of Oral and Maxillofacial Surgery , vol.64 , Issue.2 , pp. 265-269
    • Chacon, G.E.1    Bower, D.L.2    Larsen, P.E.3    McGlumphy, E.A.4    Beck, F.M.5
  • 27
    • 33751539271 scopus 로고    scopus 로고
    • An analytical study on the thermal effects of cryosurgery on selective cell destruction
    • DOI 10.1016/j.jbiomech.2005.11.005, PII S0021929005005221
    • K.J. Chua, S.K. Chou, and J.C. Ho An analytical study on the thermal effects of cryosurgery on selective cell destruction J. Biomech. 40 2007 100 116 (Pubitemid 44838693)
    • (2007) Journal of Biomechanics , vol.40 , Issue.1 , pp. 100-116
    • Chua, K.J.1    Chou, S.K.2    Ho, J.C.3
  • 28
    • 0036118087 scopus 로고    scopus 로고
    • A new animal model of femoral head osteonecrosis: One that progresses to human-like mechanical failure
    • DOI 10.1016/S0736-0266(01)00108-5, PII S0736026601001085
    • M.G. Conzemius, T.D. Brown, Y. Zhang, and R.A. Robinson A new animal model of femoral head osteonecrosis: one that progresses to human-like mechanical failure J. Orthop. Res. 20 2002 303 309 (Pubitemid 34218275)
    • (2002) Journal of Orthopaedic Research , vol.20 , Issue.2 , pp. 303-309
    • Conzemius, M.G.1    Brown, T.D.2    Zhang, Y.3    Robinson, R.A.4
  • 30
    • 28344437068 scopus 로고
    • Des Vis Metalliques Enfoncees dans le Tissue des Os, pour le Traitment de Certaines Fractures
    • U. Cucuel, and U. Rigaud Des Vis Metalliques Enfoncees dans le Tissue des Os, pour le Traitment de Certaines Fractures Revue de Medecine et Chirurgie Paris 8 1850 113 115
    • (1850) Revue de Medecine et Chirurgie Paris , vol.8 , pp. 113-115
    • Cucuel, U.1    Rigaud, U.2
  • 32
    • 84859107104 scopus 로고    scopus 로고
    • Heat transfer in bone during drilling. A thesis submitted in conformity with the requirements for the degree of Master of Applied Science
    • Institute of Biomaterials and Biomedical Engineering University of Toronto
    • S.R.H. Davidson Heat transfer in bone during drilling. A thesis submitted in conformity with the requirements for the degree of Master of Applied Science Graduate Department of Mechanical and Industrial Engineering 1999 Institute of Biomaterials and Biomedical Engineering University of Toronto
    • (1999) Graduate Department of Mechanical and Industrial Engineering
    • Davidson, S.R.H.1
  • 33
    • 0034448893 scopus 로고    scopus 로고
    • Measurement of thermal conductivity of bovine cortical bone
    • DOI 10.1016/S1350-4533(01)00003-0, PII S1350453301000030
    • S.R.H. Davidson, and D.F. James Measurement of thermal conductivity of bovine cortical bone Medical Engineering & Physics 22 2000 741 747 (Pubitemid 32378736)
    • (2000) Medical Engineering and Physics , vol.22 , Issue.10 , pp. 741-747
    • Davidson, S.R.H.1    James, D.F.2
  • 34
    • 18244417491 scopus 로고    scopus 로고
    • 'In-situ' temperature measurement to determine the machining potential of different tool coatings
    • DOI 10.1016/S0257-8972(03)00708-4
    • J. Dörr, Th. Mertens, G. Engering, and M. Lahres 'In-situ' temperature measurement to determine the machining potential of different tool coatings Surf. Coat.Technol. 174-175 2003 389 392 (Pubitemid 37054281)
    • (2003) Surface and Coatings Technology , vol.174-175 , pp. 389-392
    • Dorr, J.1    Mertens, Th.2    Engering, G.3    Lahres, M.4
  • 35
    • 3042517588 scopus 로고    scopus 로고
    • The influence of drill wear on cutting efficiency and heat production during osteotomy preparation for dental implants: A study of drill durability
    • C. Ercoli, P.D. Funkenbusch, H.J. Lee, M.E. Moss, and G.N. Graser The influence of drill wear on cutting efficiency and heat production during osteotomy preparation for dental implants: a study of drill durability Int. J. Oral Maxillofac. Implants 19 2004 335 349 (Pubitemid 38822321)
    • (2004) International Journal of Oral and Maxillofacial Implants , vol.19 , Issue.3 , pp. 335-349
    • Ercoli, C.1    Funkenbusch, P.D.2    Lee, H.-J.3    Moss, M.E.4    Graser, G.N.5
  • 36
    • 0022628142 scopus 로고
    • Temperatures during drilling for the placement of implants using the osseointegration technique
    • R.A. Eriksson, and R. Adell Temperatures during drilling for the placement of implants using the Osseo integration technique J. Oral Maxillofac. Surg. 44 1986 4 7 (Pubitemid 16154442)
    • (1986) Journal of Oral and Maxillofacial Surgery , vol.44 , Issue.1 , pp. 4-7
    • Eriksson, R.A.1    Adell, R.2
  • 38
    • 0021685213 scopus 로고
    • The effect of heat on bone regeneration: An experimental study in the rabbit using the bone growth chamber
    • R.A. Eriksson, and T. Albrektsson The effect of heat on bone regeneration: an experimental study in the rabbit using the bone growth chamber J. Oral Maxillofac. Surg. 42 1984 705 711 (Pubitemid 15215826)
    • (1984) Journal of Oral and Maxillofacial Surgery , vol.42 , Issue.11 , pp. 705-711
    • Eriksson, R.A.1    Albrektsson, T.2
  • 40
    • 0021712493 scopus 로고
    • Assessment of bone viability after heat trauma. A histological, histochemical and vital microscopic study in the rabbit
    • R.A. Eriksson, T. Albrektsson, and B. Magnusson Assessment of bone viability after heat trauma: a histological, histochemical and vital microscopic study in the rabbit Scandinavian Journal of Plastic and Reconstructive Surgery and Hand Surgery 18 1984 261 268 (Pubitemid 15167563)
    • (1984) Scandinavian Journal of Plastic and Reconstructive Surgery , vol.18 , Issue.3 , pp. 261-268
    • Eriksson, R.A.1    Albrektsson, T.2    Magnusson, B.3
  • 41
    • 84881087159 scopus 로고    scopus 로고
    • Control algorithm and preliminary user studies for a bone drilling medical training system, robot and human interactive communication
    • H. Esen, K. Yano, and M. Buss Control algorithm and preliminary user studies for a bone drilling medical training system, robot and human interactive communication Proceedings. ROMAN 2003. The 12th IEEE International Workshop 2003 153 158
    • (2003) Proceedings. ROMAN 2003. The 12th IEEE International Workshop , pp. 153-158
    • Esen, H.1    Yano, K.2    Buss, M.3
  • 43
    • 0036291772 scopus 로고    scopus 로고
    • Bone blood flow response to surgical trauma
    • DOI 10.1016/S0020-1383(02)00014-1, PII S0020138302000141
    • J.R. Field, and G. Sumner-Smith Bone blood flow response to surgical trauma Injury 33 2002 447 451 (Pubitemid 34722619)
    • (2002) Injury , vol.33 , Issue.5 , pp. 447-451
    • Field, J.R.1    Sumner-Smith, G.2
  • 44
    • 0034806506 scopus 로고    scopus 로고
    • The assessment of cortical heat during intramedullary reaming of long bones
    • DOI 10.1016/S0020-1383(01)00023-7, PII S0020138301000237
    • J.P.M. Frölke, R. Peters, K. Boshuizen, P. Patka, F.C. Bakker, and H.J. Haarman The assessment of cortical heat during intramedullary reaming of long bones Injury 32 2001 683 688 (Pubitemid 32910598)
    • (2001) Injury , vol.32 , Issue.9 , pp. 683-688
    • Frolke, J.P.M.1    Peters, R.2    Boshuizen, K.3    Patka, P.4    Bakker, F.C.5    Haarman, H.J.Th.M.6
  • 46
    • 33746581870 scopus 로고    scopus 로고
    • Steroid-induced versus cryoinsult-induced femoral head osteonecrosis: Statistical measurement of histologic abnormality focalization
    • DOI 10.1142/S021895770500159X, PII S021895770500159X
    • J.E. Goetz, Y.Y. Chung, D.L. Zimmerman, D.R. Pedersen, D.A. Robinson, and M. Conzemius Steroid-induced versus cryoinsult-induced femoral head osteonecrosis: statistical measurement of histologic abnormality focalization Journal of Musculoskeletal Research 9 2005 161 172 (Pubitemid 44151198)
    • (2005) Journal of Musculoskeletal Research , vol.9 , Issue.4 , pp. 161-172
    • Goetz, J.E.1    Chung, Y.-Y.2    Zimmerman, D.L.3    Pedersen, D.R.4    Robinson, D.A.5    Conzemius, M.G.6    Brown, T.D.7
  • 47
    • 52649122690 scopus 로고    scopus 로고
    • The apparent critical isotherm for cryoinsult-induced osteonecrotic lesions in emu femoral heads
    • J.E. Goetz, D.R. Pedersen, D.A. Robinson, M.G. Conzemius, T.E. Baer, and T.D. Brown The apparent critical isotherm for cryoinsult-induced osteonecrotic lesions in emu femoral heads J. Biomech. 41 2008 2197 2205
    • (2008) J. Biomech. , vol.41 , pp. 2197-2205
    • Goetz, J.E.1    Pedersen, D.R.2    Robinson, D.A.3    Conzemius, M.G.4    Baer, T.E.5    Brown, T.D.6
  • 49
    • 0012371775 scopus 로고
    • Eine neue Methode der Fixirung der Fragmente bei komplicierten Frakturen
    • C. Hansmann Eine neue Methode der Fixirung der Fragmente bei komplicierten Frakturen Verhandlungen der Deutschen Gesellchaft fur Chirurgie 15 1886 134 136
    • (1886) Verhandlungen der Deutschen Gesellchaft fur Chirurgie , vol.15 , pp. 134-136
    • Hansmann, C.1
  • 50
    • 84964154926 scopus 로고
    • Heat impact of revolving instruments on vital dentin tubules
    • C.J. Henschel Heat impact of revolving instruments on vital dentin tubules J. Dent. Res. 22 1943 323 333
    • (1943) J. Dent. Res. , vol.22 , pp. 323-333
    • Henschel, C.J.1
  • 51
    • 0343168054 scopus 로고    scopus 로고
    • Temperature effects in the drilling of human and bovine bone
    • DOI 10.1016/S0924-0136(99)00155-7
    • M.T. Hillerya, and I. Shuaib Temperature effects in the drilling of human and bovine bone J. Mater. Process. Technol. 92-93 1999 302 308 (Pubitemid 30535040)
    • (1999) Journal of Materials Processing Technology , vol.92-93 , pp. 302-308
    • Hillery, M.T.1    Shuaib, I.2
  • 52
    • 0017642925 scopus 로고
    • Investigation of variable factors in drilling bone
    • J.A. Hobkirk, and K.J. Rusiniak Investigation of variable factors in drilling bone Oral Surg 35 1977 968 973 (Pubitemid 8242795)
    • (1977) Journal of Oral Surgery , vol.35 , Issue.12 , pp. 968-973
    • Hobkirk, J.A.1    Rusiniak, K.2
  • 54
    • 20644431782 scopus 로고    scopus 로고
    • Accuracy study of computer-assisted drilling: The effect of bone density, drill bit characteristics, and use of a mechanical guide
    • T. Hüfner, J. Geerling, G. Oldag, M. Richter, M. Kfuri Jr., and T. Pohlemann Accuracy study of computer-assisted drilling: the effect of bone density, drill bit characteristics, and use of a mechanical guide J. Orthop. Trauma 19 2005 317 322 (Pubitemid 40835147)
    • (2005) Journal of Orthopaedic Trauma , vol.19 , Issue.5 , pp. 317-322
    • Hufner, T.1    Geerling, J.2    Oldag, G.3    Richter, M.4    Kfuri Jr., M.5    Pohlemann, T.6    Krettek, C.7
  • 55
    • 0019249787 scopus 로고
    • Some fundamental aspects of human joint replacement. Analyses of stresses and heat conduction in bone-prosthesis structures
    • R. Huiskes Some fundamental aspects of human joint replacement. Analyses of stresses and heat conduction in bone-prosthesis structures Acta Orthopedica Scandinavica 185 1980 1 208
    • (1980) Acta Orthopedica Scandinavica , vol.185 , pp. 1-208
    • Huiskes, R.1
  • 56
    • 0020553266 scopus 로고
    • Thermal osteonecrosis complicating Steinmann pin insertion in plastic surgery
    • S. Itay, and H. Tsur Thermal osteonecrosis complicating Steinmann pin insertion in plastic surgery Plastic and Reconstructive Surgery 72 1983 557 561 (Pubitemid 13012237)
    • (1983) Plastic and Reconstructive Surgery , vol.72 , Issue.4 , pp. 557-561
    • Itay, S.1    Tsur, H.2
  • 59
    • 82755182956 scopus 로고    scopus 로고
    • Influence of orthopaedic drilling parameters on temperature and histopathology of bovine tibia: An in vitro study
    • F. Karaca, B. Aksakal, and M. Kom Influence of orthopaedic drilling parameters on temperature and histopathology of bovine tibia: an in vitro study Medical Engineering & Physics 33 2011 1221 1227
    • (2011) Medical Engineering & Physics , vol.33 , pp. 1221-1227
    • Karaca, F.1    Aksakal, B.2    Kom, M.3
  • 60
    • 32444435451 scopus 로고    scopus 로고
    • The thermal properties of bone and the effects of surgical intervention
    • DOI 10.1016/j.cuor.2005.09.011, PII S0268089005001672
    • S. Karmani The thermal properties of bone and the effects of surgical intervention Current Orthopaedics 20 2006 52 58 (Pubitemid 43226663)
    • (2006) Current Orthopaedics , vol.20 , Issue.1 , pp. 52-58
    • Karmani, S.1
  • 61
    • 14644424620 scopus 로고    scopus 로고
    • The design and function of surgical drills and K-wires
    • DOI 10.1016/j.cuor.2004.12.011
    • S. Karmani, and F. Lam The design and function of surgical drills and K-wires Current Orthopedics 18 2004 484 490 (Pubitemid 40311822)
    • (2004) Current Orthopaedics , vol.18 , Issue.6 , pp. 484-490
    • Karmani, S.1    Lam, F.2
  • 64
    • 0016525310 scopus 로고
    • Entwichlung einer Innenkuhlung fur chirurgische Bohrer
    • H. Kirschner, and W. Meyer Entwichlung einer Innenkuhlung fur chirurgische Bohrer Dtsch Zahnaztl Zeitschrift 30 1975 436 438
    • (1975) Dtsch Zahnaztl Zeitschrift , vol.30 , pp. 436-438
    • Kirschner, H.1    Meyer, W.2
  • 66
    • 0020051292 scopus 로고
    • Temperature elevations in orthopaedic cutting operations
    • DOI 10.1016/0021-9290(82)90173-7
    • W.R. Krause, D.W. Bradbury, J.E. Kelly, and E.M. Lunceford Temperature elevations in orthopaedic cutting operations J. Biomech. 15 1982 267 275 (Pubitemid 12113010)
    • (1982) Journal of Biomechanics , vol.15 , Issue.4 , pp. 267-275
    • Krause, W.R.1    Bradbury, D.W.2    Kelly, J.E.3    Lunceford, E.M.4
  • 67
    • 0343129817 scopus 로고
    • Effects of torque and heat generation during direct cortical trochar tipped pin insertion
    • A. Lansari Effects of torque and heat generation during direct cortical trochar tipped pin insertion Annals of Biomechanical Engineering 19 1991 6411
    • (1991) Annals of Biomechanical Engineering , vol.19 , pp. 6411
    • Lansari, A.1
  • 68
    • 0019033815 scopus 로고
    • Effect of internal irrigation on frictional heat generated from bone drilling
    • C. Lavelle, and D. Wedgwood Effect of internal irrigation on frictional heat generated from bone drilling J. Oral Surg. 38 1980 499 503
    • (1980) J. Oral Surg. , vol.38 , pp. 499-503
    • Lavelle, C.1    Wedgwood, D.2
  • 69
    • 0015445231 scopus 로고
    • Heat and bone tissue. An experimental investigation of the thermal properties of bone and threshold levels for thermal injury
    • J. Lundskog Heat and bone tissue. An experimental investigation of the thermal properties of bone and threshold levels for thermal injury Scand. J. Plast. Reconstr. Surg. 9 1972 1 80
    • (1972) Scand. J. Plast. Reconstr. Surg. , vol.9 , pp. 1-80
    • Lundskog, J.1
  • 70
    • 0015301831 scopus 로고
    • Temperatures measured in human cortical bone while drilling
    • L.S. Matthews, and C. Hirsch Temperatures measured in human cortical bone while drilling J. Oral Maxillofac. Surg. 54 1972 297 308
    • (1972) J. Oral Maxillofac. Surg. , vol.54 , pp. 297-308
    • Matthews, L.S.1    Hirsch, C.2
  • 73
    • 0000967513 scopus 로고
    • Histopathologic reaction of bone to surgical cutting
    • R.W. Moss Histopathologic reaction of bone to surgical cutting Oral Surg. Oral Med. Oral Pathol. 17 1964 405 414
    • (1964) Oral Surg. Oral Med. Oral Pathol. , vol.17 , pp. 405-414
    • Moss, R.W.1
  • 74
    • 0028420105 scopus 로고
    • Infrared temperature measurement on diamond-coated tools during machining
    • P. Müller-Hummel, and M. Lahres Infrared temperature measurement on diamond-coated tools during machining Diamond Relat. Mater. 3 1994 765 769
    • (1994) Diamond Relat. Mater. , vol.3 , pp. 765-769
    • Müller-Hummel, P.1    Lahres, M.2
  • 75
    • 33749456517 scopus 로고    scopus 로고
    • Monitoring of bone temperature during osseous preparation for orthodontic micro-screw implants: Effect of motor speed and ressure
    • O.H. Nam, W.J. Yu, M.Y. Choi, and H.M. Kyung Monitoring of bone temperature during osseous preparation for orhodontic micro-screw implants: effect of motor speed and pressure Key Engineering Materials 321-323 2006 1044 1047 (Pubitemid 44517946)
    • (2006) Key Engineering Materials , vol.321-323 , pp. 1044-1047
    • Nam, O.1    Yu, W.2    Choi, M.Y.3    Kyung, H.-M.4
  • 76
    • 0029890494 scopus 로고    scopus 로고
    • Orthopaedic bone drills - Can they be improved? Temperature changes near the drilling face
    • C. Natali, P. Ingle, and J. Dowell Orthopaedic bone drills - can they be improved? Temperature changes near the drilling face Journal of Bone and Joint Surgery British 78B 1996 357 362 (Pubitemid 26158818)
    • (1996) Journal of Bone and Joint Surgery - Series B , vol.78 , Issue.3 , pp. 357-362
    • Natali, C.1    Ingle, P.2    Dowell, J.3
  • 79
    • 0344109565 scopus 로고    scopus 로고
    • Heat-induced segmental necrosis after reaming of one humeral and two tibial fractures with a narrow medullary canal
    • P.E. Ochsner, F. Baumgart, and G. Kohler Heat-induced segmental necrosis after reaming of one humeral and two tibial fractures with a narrow medullary canal Injury 29 Suppl. 2 1998 S1 S10
    • (1998) Injury , vol.29 , Issue.SUPPL. 2
    • Ochsner, P.E.1    Baumgart, F.2    Kohler, G.3
  • 84
    • 0000714284 scopus 로고
    • Temperature changes during high-speed drilling on bone
    • S. Rafel Temperature changes during high-speed drilling on bone J. Oral Surg. Anesth. Hosp. Dent. Serv. 20 1962 475 477
    • (1962) J. Oral Surg. Anesth. Hosp. Dent. Serv. , vol.20 , pp. 475-477
    • Rafel, S.1
  • 86
    • 0031152012 scopus 로고    scopus 로고
    • Influence of different parameters on bone heating and drilling time in implantology
    • Y. Reingewirtz, S. Szmukler-Moncler, and B. Senger Influence of different parameters on bone heating and drilling time in implantology Clinical Oral Implants 8 1997 189 197 (Pubitemid 127688454)
    • (1997) Clinical Oral Implants Research , vol.8 , Issue.3 , pp. 189-197
    • Reingewirtz, Y.1    Szmukler-Moncler, S.2    Senger, B.3
  • 88
    • 0030915338 scopus 로고    scopus 로고
    • Ultrapower surgical drill system evaluation
    • DOI 10.1016/S0090-3019(96)00386-2, PII S0090301996003862
    • B.Z. Roitberg, M. Dujovny, and I. Lim UltraPower surgical drill system evaluation Surg. Neurol. 47 1997 392 393 (Pubitemid 27157509)
    • (1997) Surgical Neurology , vol.47 , Issue.4 , pp. 392-393
    • Roitberg, B.Z.1    Dujovny, M.2    Lim, J.3
  • 90
    • 0020172669 scopus 로고
    • Surgical drilling: Design and performance of an improved drill
    • S. Saha, S. Pal, and J.A. Albright Surgical drilling design and performance of an improved drill J. Biomech. Eng. 104 1982 245 252 (Pubitemid 12566130)
    • (1982) Journal of Biomechanical Engineering , vol.104 , Issue.3 , pp. 245-252
    • Saha, S.1    Pal, S.2    Albright, J.A.3
  • 91
    • 60049100274 scopus 로고    scopus 로고
    • Effects of irrigation temperature on heat control in vitro at different drilling depths
    • B.C. Sener, G. Dergin, B. Gursoy, E. Kelesoglu, and I. Slih Effects of irrigation temperature on heat control in vitro at different drilling depths Clin. Oral Implants Res. 20 2009 294 298
    • (2009) Clin. Oral Implants Res. , vol.20 , pp. 294-298
    • Sener, B.C.1    Dergin, G.2    Gursoy, B.3    Kelesoglu, E.4    Slih, I.5
  • 92
    • 0036788376 scopus 로고    scopus 로고
    • Heat generation during implant drilling: The significance of motor speed
    • M. Sharawy, C.E. Misch, N. Weller, and S. Tehemar Heat generation during implant drilling: the significance of motor speed J. Oral Maxillofac. Surg. 60 2002 1160 1169
    • (2002) J. Oral Maxillofac. Surg. , vol.60 , pp. 1160-1169
    • Sharawy, M.1    Misch, C.E.2    Weller, N.3    Tehemar, S.4
  • 94
    • 0038273736 scopus 로고
    • Early reaction in bone following the use of burs rotating at conventional and ultra speeds
    • S. Spatz Early reaction in bone following the use of burs rotating at conventional and ultra speeds Oral Surg. Oral Med. Oral Pathol. 19 1965 808 816
    • (1965) Oral Surg. Oral Med. Oral Pathol. , vol.19 , pp. 808-816
    • Spatz, S.1
  • 95
    • 0032601842 scopus 로고    scopus 로고
    • Factors affecting heat generation during implant site preparations: A review of biologic observations and future considerations
    • S.H. Tehemar Factors affecting heat generation during implant site preparations: a review of biologic observations and future considerations Int. J. Oral Maxillofac. Implants 14 1999 127 136
    • (1999) Int. J. Oral Maxillofac. Implants , vol.14 , pp. 127-136
    • Tehemar, S.H.1
  • 96
    • 0002041851 scopus 로고
    • Effect of drilling on bone
    • H.C. Thompson Effect of drilling on bone J. Oral Surg. 16 1958 22 30
    • (1958) J. Oral Surg. , vol.16 , pp. 22-30
    • Thompson, H.C.1
  • 97
    • 78449276928 scopus 로고    scopus 로고
    • Finite element modeling of kirschner pin and bone thermal contact during drilling
    • Y.K. Tu, Y.Y. Hong, and Y.C. Chen Finite element modeling of kirschner pin and bone thermal contact during drilling Life Science Journal 6 2009 23 27
    • (2009) Life Science Journal , vol.6 , pp. 23-27
    • Tu, Y.K.1    Hong, Y.Y.2    Chen, Y.C.3
  • 100
    • 0342670897 scopus 로고
    • A comparison of the heat production and mechanical efficiency of diamond instruments, stones, and burs at 3000 and 60,000 rpm
    • J.P. Walsh, and H.F. Symmons A comparison of the heat production and mechanical efficiency of diamond instruments, stones, and burs at 3000 and 60,000 rpm New Zeland Dental Journal 45 1949 28 32
    • (1949) New Zeland Dental Journal , vol.45 , pp. 28-32
    • Walsh, J.P.1    Symmons, H.F.2
  • 101
    • 0026873629 scopus 로고
    • Heat distribution in bone during preparation of implant sites: Heat analysis by real-time thermography
    • F. Watanabe, Y. Tawada, S. Komatsu, and Y. Hata Heat distribution in bone during preparation of implant sites: heat analysis by real-time thermography Int. J. Oral Maxillofac. Implants 7 1992 212 219
    • (1992) Int. J. Oral Maxillofac. Implants , vol.7 , pp. 212-219
    • Watanabe, F.1    Tawada, Y.2    Komatsu, S.3    Hata, Y.4
  • 103
    • 0017186903 scopus 로고
    • The clinical measurement of skeletal blood flow
    • R. Wootton, J. Reeve, and N. Veall The clinical measurement of skeletal blood flow Clin. Sci. Mol. Med. 50 1976 261 268
    • (1976) Clin. Sci. Mol. Med. , vol.50 , pp. 261-268
    • Wootton, R.1    Reeve, J.2    Veall, N.3
  • 104
    • 1842726042 scopus 로고
    • Thermophysical properties of compact bone
    • E.S. Zelenov Thermophysical properties of compact bone Mechanics of Composite Materials 21 1985 1092 1095
    • (1985) Mechanics of Composite Materials , vol.21 , pp. 1092-1095
    • Zelenov, E.S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.