메뉴 건너뛰기




Volumn 48, Issue 2, 2012, Pages 593-602

Classification of hazardous areas produced by maintenance interventions on N.G. distribution networks and in the presence of open surface of flammable liquid

Author keywords

Hazardous area classification; inflammable liquid; natural gas

Indexed keywords

ELECTRIC POWER DISTRIBUTION; FLAMMABILITY; HAZARDS; LIQUIDS; NATURAL GAS;

EID: 84859051877     PISSN: 00939994     EISSN: None     Source Type: Journal    
DOI: 10.1109/TIA.2011.2180690     Document Type: Article
Times cited : (5)

References (17)
  • 1
    • 0018989292 scopus 로고
    • Area classification-past, present, and future
    • Mar./Apr.
    • T. B. Smith, "Area classification-past, present, and future," IEEE Trans. Ind. Appl., vol. IA-16, no. 2, pp. 285-291, Mar./Apr. 1980.
    • (1980) IEEE Trans. Ind. Appl. , vol.IA-16 , Issue.2 , pp. 285-291
    • Smith, T.B.1
  • 2
    • 0023246638 scopus 로고
    • Electrical area classification - basic application, experience, and judgment
    • N. Penny and Z. Peceli, "Electrical area classification-Basic application, experience, and judgment," IEEE Trans. Ind. Appl., vol. IA-23, no. I, pp. 19-27, Jan./Feb. 1987. (Pubitemid 17549527)
    • (1987) IEEE Transactions on Industry Applications , vol.IA-23 , Issue.1 , pp. 19-27
    • Penny, N.1    Peceli, Z.2
  • 3
    • 85034956618 scopus 로고    scopus 로고
    • Directive 94/9/EC of the European Parliament and the Council of 23 March 1994 on the Approximation of the Laws of the Member States Concerning Equipment and Protective Systems Intended for Use in Potentially Explosive Atmospheres Bruxelles 1994
    • Directive 94/9/EC of the European Parliament and the Council of 23 March 1994 on the Approximation of the Laws of the Member States Concerning Equipment and Protective Systems Intended for Use in Potentially Explosive Atmospheres, Bruxelles1994.
  • 4
    • 85035058832 scopus 로고    scopus 로고
    • Directive 1999/92/EC of the European Parliament and of the Council of 16 December 1999 on Minimum Requirements for Improving the Safety and Health Protection of Workers Potentially at Risk From Explosive Atmospheres Bruxelles1999
    • Directive 1999/92/EC of the European Parliament and of the Council of 16 December 1999 on Minimum Requirements for Improving the Safety and Health Protection of Workers Potentially at Risk From Explosive Atmospheres, Bruxelles1999.
  • 7
    • 33947247466 scopus 로고    scopus 로고
    • Applying the API alternate method for area classification
    • DOI 10.1109/TIA.2006.887000
    • J. E. Propst, L. A. Barrios, Jr., and B. Lobitz, "Applying the API alternate method for area classification," IEEE Trans. Ind. Appl., vol. 43, no. 1, pp. 162-171, Jan./Feb. 2007. (Pubitemid 46431386)
    • (2007) IEEE Transactions on Industry Applications , vol.43 , Issue.1 , pp. 162-171
    • Propst, J.E.1    Barrios Jr., L.A.2    Lobitz, B.3
  • 8
    • 0027627173 scopus 로고
    • NEC versus IECmethods of protection for class I, division 1 versus zone 1, hazardous (classified) locations-a comparative analysis
    • Jul./Aug.
    • J. H. Kuczka and A. R. Hopmann, "NEC versus IECmethods of protection for class I, division 1 versus zone 1, hazardous (classified) locations-a comparative analysis," IEEE Trans. Ind. Appl., vol. 29, no. 4, pp. 716-720, Jul./Aug. 1993.
    • (1993) IEEE Trans. Ind. Appl. , vol.29 , Issue.4 , pp. 716-720
    • Kuczka, J.H.1    Hopmann, A.R.2
  • 11
    • 84859031646 scopus 로고    scopus 로고
    • Zone con pericolo di esplosione determinato da una pozza di sostanza infiammabile
    • Nov.
    • A. Abate, R. Pomè, and R. Tommasini, "Zone con pericolo di esplosione determinato da una pozza di sostanza infiammabile," N.T. Tecnica tecnologia n. 11/98, pp. 1-4, Nov. 1998.
    • (1998) N.T. Tecnica Tecnologia , Issue.11-98 , pp. 1-4
    • Abate, A.1    Pomè, R.2    Tommasini, R.3
  • 12
    • 84855355106 scopus 로고    scopus 로고
    • Impianti elettrici nei luoghi con pericolo di esplosione: comportamento dei gas nella formazione di atmosfere esplodibili
    • Dec.
    • A. Abate, R. Pomè, and R. Tommasini, "Impianti elettrici nei luoghi con pericolo di esplosione: comportamento dei gas nella formazione di atmosfere esplodibili," Automazione Energia Informazione (AEI), vol. 85, no. 12, pp. 879-886, Dec. 1998.
    • (1998) Automazione Energia Informazione (AEI) , vol.85 , Issue.12 , pp. 879-886
    • Abate, A.1    Pomè, R.2    Tommasini, R.3
  • 13
    • 84859011305 scopus 로고    scopus 로고
    • Electrical apparatus for explosive gas atmosphere: A contribution to the evaluation of hazardous areas in indoor places
    • Edinburgh, U.K. May 15-17
    • R. Tommasini, "Electrical apparatus for explosive gas atmosphere: A contribution to the evaluation of hazardous areas in indoor places," in Proc. ESREL SARS SRA Eur. Annu. Conf.-Foresight Precautions, Edinburgh, U.K., May 15-17, 2000, pp. 723-727.
    • (2000) Proc. ESREL SARS SRA Eur. Annu. Conf.-Foresight Precautions , pp. 723-727
    • Tommasini, R.1
  • 16
    • 79960668821 scopus 로고    scopus 로고
    • Classification of hazardous areas: Standard, theory and practice
    • 42nd ed., Waldenburg, Germany, R. Stahl Schaltgeräte GmbH, Sep.
    • E. Rangel, Jr., "Classification of Hazardous Areas: Standard, theory and practice," Ex Magazine, 42nd ed., Waldenburg, Germany, R. Stahl Schaltgeräte GmbH, Sep. 2010, pp. 15-21.
    • (2010) Ex Magazine , pp. 15-21
    • Rangel Jr., E.1
  • 17
    • 77956920711 scopus 로고    scopus 로고
    • Flammable mixture analysis for hazardous area classification
    • Sep./Oct.
    • A. Bozek and V. Rowe, "Flammable mixture analysis for hazardous area classification," IEEE Trans. Ind. Appl., vol. 46, no. 5, pp. 1827-1835, Sep./Oct. 2010.
    • (2010) IEEE Trans. Ind. Appl. , vol.46 , Issue.5 , pp. 1827-1835
    • Bozek, A.1    Rowe, V.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.