메뉴 건너뛰기




Volumn 3, Issue 2, 2012, Pages 231-241

Robust fuzzy fault-tolerant control of wind energy conversion systems subject to sensor faults

Author keywords

Fault detection and isolation (FDI); fault tolerant control; fuzzy controller; fuzzy observer; linear matrix inequalities (LMIs); parameters uncertainties; robust control; sensor faults; Takagi Sugeno (TS) fuzzy model; wind turbine control

Indexed keywords

FAULT DETECTION AND ISOLATION; FAULT-TOLERANT CONTROL; FUZZY CONTROLLERS; FUZZY OBSERVER; LINEAR MATRIX INEQUALITIES (LMIS); PARAMETERS UNCERTAINTIES; SENSOR FAULTS; TAKAGI-SUGENO FUZZY MODELS; WIND TURBINE CONTROL;

EID: 84859022117     PISSN: 19493029     EISSN: None     Source Type: Journal    
DOI: 10.1109/TSTE.2011.2178105     Document Type: Article
Times cited : (156)

References (35)
  • 2
    • 10244259173 scopus 로고    scopus 로고
    • Dynamical variable structure controller for power regulation of wind energy conversion systems
    • Dec.
    • H. D. Battista and R. J. Mantz, "Dynamical variable structure controller for power regulation of wind energy conversion systems, " IEEE Trans. Energy Convers., vol. 19, no. 4, pp. 756-763, Dec. 2004.
    • (2004) IEEE Trans. Energy Convers. , vol.19 , Issue.4 , pp. 756-763
    • Battista, H.D.1    Mantz, R.J.2
  • 3
    • 0034460478 scopus 로고    scopus 로고
    • Dynamical sliding mode power control of wind driven induction generators
    • DOI 10.1109/60.900507
    • H. Battista, R. J. Mantz, and C. F. Christiansen, "Dynamical sliding mode power control of wind driven induction generators, " IEEE Trans. Energy Convers., vol. 15, no. 4, pp. 451-457, Dec. 2000. (Pubitemid 32252040)
    • (2000) IEEE Transactions on Energy Conversion , vol.15 , Issue.4 , pp. 451-457
    • De Battista, H.1    Mantz, R.J.2    Christiansen, C.F.3
  • 7
    • 12444299022 scopus 로고    scopus 로고
    • Robust stabilization for delayed discrete-time fuzzy systems via basis-dependent Lyapunov-Krasovskii function
    • DOI 10.1016/j.fss.2004.08.014, PII S016501140400363X
    • S. Zhou and T. Li, "Robust stabilization for delayed discrete-time fuzzy systems via basis-dependent Lyapunov-Krasovskii function, " Fuzzy Sets Syst., vol. 151, no. 1, pp. 139-153, Apr. 2005. (Pubitemid 40146245)
    • (2005) Fuzzy Sets and Systems , vol.151 , Issue.1 , pp. 139-153
    • Zhou, S.1    Li, T.2
  • 8
    • 77954901024 scopus 로고    scopus 로고
    • Sensor fault detection and isolation for wind turbines based on subspace identification and Kalman filter techniques
    • Dec.
    • X. Wei, M. Verhaegen, and T. van Engelen, "Sensor fault detection and isolation for wind turbines based on subspace identification and Kalman filter techniques, " Int. J. Adapt. Control Signal Process., vol. 24, no. 8, pp. 687-707, Dec. 2010.
    • (2010) Int. J. Adapt. Control Signal Process. , vol.24 , Issue.8 , pp. 687-707
    • Wei, X.1    Verhaegen, M.2    Van Engelen, T.3
  • 14
    • 70350426939 scopus 로고    scopus 로고
    • Current sensor faulttolerant control for WECS with DFIG
    • Nov.
    • S. Karimi, A. Gaillard, P. Poure, and S. Saadate, "Current sensor faulttolerant control for WECS with DFIG, " IEEE Trans. Ind. Electron., vol. 56, no. 11, pp. 4660-4670, Nov. 2009.
    • (2009) IEEE Trans. Ind. Electron. , vol.56 , Issue.11 , pp. 4660-4670
    • Karimi, S.1    Gaillard, A.2    Poure, P.3    Saadate, S.4
  • 15
    • 77957778873 scopus 로고    scopus 로고
    • Active and passive fault-tolerant LPV control of wind turbines
    • Baltimore, MD, USA, Jun. 30-Jul. 02
    • C. Sloth, T. Esbensen, and J. Stoustrup, "Active and passive fault-tolerant LPV control of wind turbines, " in Proc. American Control Conf., Baltimore, MD, USA, Jun. 30-Jul. 02, 2010, pp. 4640-4646.
    • (2010) Proc. American Control Conf. , pp. 4640-4646
    • Sloth, C.1    Esbensen, T.2    Stoustrup, J.3
  • 16
    • 70350734458 scopus 로고    scopus 로고
    • Fault-tolerant switched reluctance machine for wind turbine blade pitch control
    • Jun. 9-11
    • M. Ruba, L. Szabo, and F. Jurca, "Fault-tolerant switched reluctance machine for wind turbine blade pitch control, " in Proc. Int. Conf. Clean Electrical Power, Jun. 9-11, 2009, pp. 721-726.
    • (2009) Proc. Int. Conf. Clean Electrical Power , pp. 721-726
    • Ruba, M.1    Szabo, L.2    Jurca, F.3
  • 17
    • 78650203561 scopus 로고    scopus 로고
    • Fault-tolerant control for a modular generator-converter scheme for direct drive wind turbines
    • Jun.
    • M. A. Parker, C. Ng, and L. Ran, "Fault-tolerant control for a modular generator-converter scheme for direct drive wind turbines, " IEEE Trans. Ind. Electron., vol. 58, no. 1, pp. 305-315, Jun. 2011.
    • (2011) IEEE Trans. Ind. Electron. , vol.58 , Issue.1 , pp. 305-315
    • Parker, M.A.1    Ng, C.2    Ran, L.3
  • 18
    • 79957493476 scopus 로고    scopus 로고
    • Robust and fault-tolerant linear parameter-varying control of wind turbines
    • Jun.
    • C. Sloth, T. Esbensen, and J. Stoustrup, "Robust and fault-tolerant linear parameter-varying control of wind turbines, " Mechatronics, vol. 21, no. 4, pp. 645-659, Jun. 2011.
    • (2011) Mechatronics , vol.21 , Issue.4 , pp. 645-659
    • Sloth, C.1    Esbensen, T.2    Stoustrup, J.3
  • 19
    • 57849097544 scopus 로고    scopus 로고
    • Design of hardware fault tolerant control architecture for wind energy conversion system with DFIG based on Reliability Analysis
    • Jun. 30-Jul. 2
    • P. Weber, P. Poure, D. Theilliol, and S. Saadate, "Design of hardware fault tolerant control architecture for wind energy conversion system with DFIG based on Reliability Analysis, " in Proc. IEEE Int. Symp. Industrial Electronics, Jun. 30-Jul. 2, 2008, pp. 2323-2328.
    • (2008) Proc. IEEE Int. Symp. Industrial Electronics , pp. 2323-2328
    • Weber, P.1    Poure, P.2    Theilliol, D.3    Saadate, S.4
  • 20
    • 77956034355 scopus 로고    scopus 로고
    • Design of two-frequency-loop robust fault tolerant controller for wind energy conversion systems
    • Jun. 15-17
    • X. Wang, Y. Wang, Z. Ji, and D. Wu, "Design of two-frequency-loop robust fault tolerant controller for wind energy conversion systems, " in Proc. 5th IEEE Conf. Industrial Electronics and Applications, Jun. 15-17, 2010, pp. 718-723.
    • (2010) Proc. 5th IEEE Conf. Industrial Electronics and Applications , pp. 718-723
    • Wang, X.1    Wang, Y.2    Ji, Z.3    Wu, D.4
  • 21
    • 74149085968 scopus 로고    scopus 로고
    • An intelligent maximum power extraction algorithm for hybrid wind-diesel-storage system
    • Mar.
    • E. Kamal, M. Koutb, A. A. Sobaih, and B. Abozalam, "An intelligent maximum power extraction algorithm for hybrid wind-diesel-storage system, " Int. J. Elect. Power Energy Syst., vol. 32, no. 3, pp. 170-177, Mar. 2010.
    • (2010) Int. J. Elect. Power Energy Syst. , vol.32 , Issue.3 , pp. 170-177
    • Kamal, E.1    Koutb, M.2    Sobaih, A.A.3    Abozalam, B.4
  • 22
    • 37549001310 scopus 로고    scopus 로고
    • Multisensor switching control strategy with fault tolerance guarantees
    • Jan.
    • M. Seron, X. Zhuo, J. De Donà, and J. Martinez, "Multisensor switching control strategy with fault tolerance guarantees, " Automatica, vol. 44, no. 1, pp. 88-97, Jan. 2008.
    • (2008) Automatica , vol.44 , Issue.1 , pp. 88-97
    • Seron, M.1    Zhuo, X.2    De Donà, J.3    Martinez, J.4
  • 23
    • 0348170751 scopus 로고    scopus 로고
    • Multi-sensor optimal information fusion Kalman filters with applications
    • Jan.
    • S.-L. Sun, "Multi-sensor optimal information fusion Kalman filters with applications, " Aerospace Sci. Technol., vol. 8, no. 1, pp. 57-62, Jan. 2004.
    • (2004) Aerospace Sci. Technol. , vol.8 , Issue.1 , pp. 57-62
    • Sun, S.-L.1
  • 24
    • 0142163128 scopus 로고    scopus 로고
    • Multisensor fusion and integration: Approaches, applications, and future research directions
    • DOI 10.1109/JSEN.2002.1000251, PII S1530437X02039416
    • R. C. Luo, C.-C. Yih, and K. L. Su, "Multisensor fusion and integration: Approaches, applications, and future research directions, " IEEE Sensors J., vol. 2, no. 2, pp. 107-119, Apr. 2002. (Pubitemid 44357916)
    • (2002) IEEE Sensors Journal , vol.2 , Issue.2 , pp. 107-119
    • Luo, R.C.1    Yih, C.-C.2    Su, K.L.3
  • 26
    • 1842499394 scopus 로고    scopus 로고
    • Oxford U. K. : Butterworth Heinemann
    • R. S. Burns, Advanced Control Engineering. Oxford, U. K. : Butterworth Heinemann, 2001, p. 326.
    • (2001) Advanced Control Engineering , pp. 326
    • Burns, R.S.1
  • 28
    • 0021892282 scopus 로고
    • Fuzzy identification of systems and its applications to modeling and control
    • Feb.
    • T. Takagi and M. Sugeno, "Fuzzy identification of systems and its applications to modeling and control, " IEEE Trans. Syst., Man, Cybern., vol. 15, no. 1, pp. 116-132, Feb. 1985.
    • (1985) IEEE Trans. Syst., Man, Cybern. , vol.15 , Issue.1 , pp. 116-132
    • Takagi, T.1    Sugeno, M.2
  • 29
    • 0026644930 scopus 로고
    • Stability analysis and design of fuzzy control systems
    • Jan.
    • K. Tanaka and M. Sugeno, "Stability analysis and design of fuzzy control systems, " Fuzzy Sets Syst., vol. 45, no. 2, pp. 135-156, Jan. 1992.
    • (1992) Fuzzy Sets Syst. , vol.45 , Issue.2 , pp. 135-156
    • Tanaka, K.1    Sugeno, M.2
  • 30
    • 0030082869 scopus 로고    scopus 로고
    • ∞ control theory, and linear matrix inequalities
    • PII S1063670696006406
    • K. Tanaka, T. Ikeda, and H. O. Wag, "Robust stabilization of a class of uncertain nonlinear systems via fuzzy control: Quadratic stabilizability, control theory, and Linear Matrix Inequalities, " IEEE Trans. Fuzzy Syst., vol. 4, no. 1, pp. 1-13, Feb. 1996. (Pubitemid 126782416)
    • (1996) IEEE Transactions on Fuzzy Systems , vol.4 , Issue.1 , pp. 1-13
    • Tanaka, K.1    Ikeda, T.2    Wang, H.O.3
  • 31
    • 0035302796 scopus 로고    scopus 로고
    • Parameterized linear matrix inequality techniques in fuzzy control system design
    • DOI 10.1109/91.919253, PII S1063670601028259
    • H. D. Tuan, P. Apkarian, T. NariKiyo, and Y. Yamamoto, "Parameterized linear matrix inequality techniques in fuzzy system desgin, " IEEE Trans. Fuzzy Syst., vol. 9, no. 2, pp. 324-332, Apr. 2001. (Pubitemid 32505588)
    • (2001) IEEE Transactions on Fuzzy Systems , vol.9 , Issue.2 , pp. 324-332
    • Tuan, H.D.1    Apkarian, P.2    Narikiyo, T.3    Yamamoto, Y.4
  • 32
    • 56349172067 scopus 로고    scopus 로고
    • Exploiting maximum energy from variable speed wind power generation system by using an adaptive Takagi-Sugeno-Kang fuzzy model
    • Feb.
    • V. Galdi, A. Piccolo, and P. Siano, "Exploiting maximum energy from variable speed wind power generation system by using an adaptive Takagi-Sugeno-Kang fuzzy model, " Energy Convers. Manage., vol. 50, no. 2, pp. 413-421, Feb. 2009.
    • (2009) Energy Convers. Manage. , vol.50 , Issue.2 , pp. 413-421
    • Galdi, V.1    Piccolo, A.2    Siano, P.3
  • 34
    • 78349310237 scopus 로고    scopus 로고
    • Comparision between linear and nonlinear control strategies for variable speed wind turbines
    • Dec.
    • B. Boukhezzar and H. Siguerdidjane, "Comparision between linear and nonlinear control strategies for variable speed wind turbines, " Control Eng. Pract., vol. 18, no. 12, pp. 1357-1368, Dec. 2010.
    • (2010) Control Eng. Pract. , vol.18 , Issue.12 , pp. 1357-1368
    • Boukhezzar, B.1    Siguerdidjane, H.2
  • 35
    • 84859068946 scopus 로고    scopus 로고
    • Maximum power control of hybrid wind-diesel-storage system
    • Jan.
    • E. Kamal, M. Koutb, A. A. Sobaih, and S. Kaddah, "Maximum power control of hybrid wind-diesel-storage system, " Adv. Fuzzy Syst., vol. 8, pp. 1-10, Jan. 2008.
    • (2008) Adv. Fuzzy Syst. , vol.8 , pp. 1-10
    • Kamal, E.1    Koutb, M.2    Sobaih, A.A.3    Kaddah, S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.