메뉴 건너뛰기




Volumn 114, Issue 4, 2012, Pages 771-775

Poor accuracy of noninvasive cardiac output monitoring using bioimpedance cardiography [PhysioFlow®] compared to magnetic resonance imaging in pediatric patients

Author keywords

[No Author keywords available]

Indexed keywords

ANESTHESIA; ARTICLE; ARTIFACT; BIOIMPEDANCE CARDIOGRAPHY; CARDIOGRAPHY; CARDIOVASCULAR MAGNETIC RESONANCE; CHILD; CLINICAL ARTICLE; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; FEMALE; HEART OUTPUT MEASUREMENT; HEART SEPTUM DEFECT; HEART SINGLE VENTRICLE; HUMAN; INFANT; INTERMETHOD COMPARISON; MALE; NEWBORN; PRESCHOOL CHILD; PRIORITY JOURNAL; SCHOOL CHILD;

EID: 84859020456     PISSN: 00032999     EISSN: None     Source Type: Journal    
DOI: 10.1213/ANE.0b013e318246c32c     Document Type: Article
Times cited : (28)

References (13)
  • 1
    • 0344406137 scopus 로고    scopus 로고
    • Measured versus estimated oxygen consumption in ventilated patients with congenital heart disease: The validity of predictive equations
    • DOI 10.1097/01.CCM.0000060010.81321.45
    • Li J, Schulze-Neick I, Penny DJ, Redington AN, Shekerdemian LS. Measured versus estimated oxygen consumption in ventilated patients with congenital heart disease: the validity of predictive equations. Crit Care Med 2003;31:1235-40 (Pubitemid 36444438)
    • (2003) Critical Care Medicine , vol.31 , Issue.4 , pp. 1235-1240
    • Li, J.1    Bush, A.2    Schulze-Neick, I.3    Penny, D.J.4    Redington, A.N.5    Shekerdemian, L.S.6
  • 4
    • 0034016549 scopus 로고    scopus 로고
    • Phase-velocity cine magnetic resonance imaging measurement of pulsatile blood flow in children and young adults: In vitro and in vivo validation
    • DOI 10.1007/s002469910014
    • Powell AJ, Maier SE, Chung T, Geva T. Phase-velocity cine magnetic resonance imaging measurement of pulsatile blood flow in children and young adults: in vitro and in vivo validation. Pediatr Cardiol 2000;21:104-10 (Pubitemid 30230909)
    • (2000) Pediatric Cardiology , vol.21 , Issue.2 , pp. 104-110
    • Powell, A.J.1    Maier, S.E.2    Chung, T.3    Geva, T.4
  • 5
    • 4143126401 scopus 로고    scopus 로고
    • Novel method of quantifying pulmonary vascular resistance by use of simultaneous invasive pressure monitoring and phase-contrast magnetic resonance flow
    • DOI 10.1161/01.CIR.0000138741.72946.84
    • Muthurangu V, Taylor A, Andriantsimiavona R, Hegde S, Miquel ME, Tulloh R, Baker E, Hill DL, Razavi RS. Novel method of quantifying pulmonary vascular resistance by use of simultaneous invasive pressure monitoring and phase-contrast magnetic resonance flow. Circulation 2004;110:826-34 (Pubitemid 39096011)
    • (2004) Circulation , vol.110 , Issue.7 , pp. 826-834
    • Muthurangu, V.1    Taylor, A.2    Andriantsimiavona, R.3    Hegde, S.4    Miquel, M.E.5    Tulloh, R.6    Baker, E.7    Hill, D.L.G.8    Razavi, R.S.9
  • 6
    • 0017864678 scopus 로고
    • Geometric method for measuring body surface area: A height-weight formula validated in infants, children, and adults
    • Haycock G, Schwartz G, Wisotsky D. Geometric method for measuring body surface area: a height-weight formula validated in infants, children and adults. J Pediatr 1978;93:62-6 (Pubitemid 8351870)
    • (1978) Journal of Pediatrics , vol.93 , Issue.1 , pp. 62-66
    • Haycock, G.B.1    Schwartz, G.J.2    Wisotsky, D.H.3
  • 7
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    • DOI 10.1023/A:1009982611386
    • Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comp 1999;15:85-91 (Pubitemid 29278438)
    • (1999) Journal of Clinical Monitoring and Computing , vol.15 , Issue.2 , pp. 85-91
    • Critchley, L.A.H.1    Critchley, J.A.J.H.2
  • 8
    • 51449103916 scopus 로고    scopus 로고
    • Impedance cardiography: A rapid and cost effective screening tool for cardiac disease
    • Bour J, Kellett JG. Impedance cardiography: a rapid and cost effective screening tool for cardiac disease. Eur J Intern Med 2008;19:399-405
    • (2008) Eur J Intern Med , vol.19 , pp. 399-405
    • Bour, J.1    Kellett, J.G.2
  • 11
    • 20344405197 scopus 로고    scopus 로고
    • 2 and maximal cardiac output assessed using thoracic bioimpedance in children
    • DOI 10.1007/s00421-004-1300-5
    • Welsman J, Bywater K, Farr C, Welford D, Armstrong N. Reliability of peak VO2 and maximal cardiac output assessed using thoracic bioimpedance in children. Eur J Appl Physiol 2005;94:228-34 (Pubitemid 40778758)
    • (2005) European Journal of Applied Physiology , vol.94 , Issue.3 , pp. 228-234
    • Welsman, J.1    Bywater, K.2    Farr, C.3    Welford, D.4    Armstrong, N.5
  • 12
    • 0033959569 scopus 로고    scopus 로고
    • Blood flow measurement by magnetic resonance imaging in congenital heart disease
    • DOI 10.1007/s002469910007
    • Powell AJ, Geva T. Blood flow measurement by magnetic resonance imaging in congenital heart disease. Pediatr Cardiol 2000;21:47-58 (Pubitemid 30068815)
    • (2000) Pediatric Cardiology , vol.21 , Issue.1 , pp. 47-58
    • Powell, A.J.1    Geva, T.2
  • 13
    • 0032928203 scopus 로고    scopus 로고
    • The use of propofol infusions in paediatric anaesthesia: A practical guide
    • DOI 10.1046/j.1460-9592.1999.00364.x
    • McFarlan CS, Anderson BJ, Short TG. The use of propofol infusions in paediatric anaesthesia: a practical guide. Paediatr Anaesth 1999;9:209-16 (Pubitemid 29220117)
    • (1999) Paediatric Anaesthesia , vol.9 , Issue.3 , pp. 209-216
    • McFarlan, C.S.1    Anderson, B.J.2    Short, T.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.