메뉴 건너뛰기




Volumn , Issue , 2011, Pages 362-366

A nanomonitor compared to ELISA for C-reactive protein detection in patient blood

Author keywords

[No Author keywords available]

Indexed keywords

ANTIBODY BINDING; BLOOD SAMPLES; C-REACTIVE PROTEINS; CARDIO-VASCULAR DISEASE; COHORT STUDIES; CRITICAL TIME; ELECTRICAL IMPEDANCE SPECTROSCOPY; HIGH DENSITY; INDUSTRY STANDARDS; INTER-ASSAY COEFFICIENTS; MICRO-SCALES; MIXED EFFECTS MODELS; MULTISCALES; NANO-POROUS ALUMINA MEMBRANES; PATIENT CARE; PROTEIN DETECTION; STATISTICAL DIFFERENCES; STATISTICAL TECHNIQUES; VASCULAR SURGERY;

EID: 84858990172     PISSN: 19449399     EISSN: 19449380     Source Type: Conference Proceeding    
DOI: 10.1109/NANO.2011.6144392     Document Type: Conference Paper
Times cited : (2)

References (13)
  • 1
    • 0035902938 scopus 로고    scopus 로고
    • Nanowire nanosensors for highly sensitive and selective detection of biological and chemical species
    • Cui, Y., Wei, Q.Q., Park, H.K. and Lieber, CM. Nanowire nanosensors for highly sensitive and selective detection of biological and chemical species. Science. 2001. 293: p.1289-92.
    • (2001) Science , vol.293 , pp. 1289-1292
    • Cui, Y.1    Wei, Q.Q.2    Park, H.K.3    Lieber, C.M.4
  • 2
    • 9644289349 scopus 로고    scopus 로고
    • Real-time, label-free monitoring of tumor antigen and serum antibody interactions
    • Campagnolo, C. et al., Real-Time, label-free monitoring of tumor antigen and serum antibody interactions. J. Biochem. Biophys. Methods, 2004. 61: p.283-98.
    • (2004) J. Biochem. Biophys. Methods , vol.61 , pp. 283-298
    • Campagnolo, C.1
  • 3
    • 0037648348 scopus 로고    scopus 로고
    • The case for early detection
    • Etzioni, R. et al., The case for early detection. Nat. Rev. Cancer. 2003. 3.p.243-52.
    • (2003) Nat. Rev. Cancer , vol.3 , pp. 243-252
    • Etzioni, R.1
  • 4
    • 0037078969 scopus 로고    scopus 로고
    • Comparison of C-reactive protein and low-density lipoprotein cholesterol levels in the prediction of first cardiovascular events
    • Nov 14
    • Ridker, PM, et al, Comparison of C-reactive protein and low-density lipoprotein cholesterol levels in the prediction of first cardiovascular events, N Engl J Med, vol. 347, pp. 1557-65, Nov 14 2002.
    • (2002) N Engl J Med , vol.347 , pp. 1557-1565
    • Ridker, P.M.1
  • 5
    • 66349102004 scopus 로고    scopus 로고
    • Incremental value of high-sensitivity C-reactive protein and N-terminal pro-B-type natriuretic peptide for the prediction of postoperative cardiac events in noncardiac vascular surgery patients
    • Mar 24
    • Goei D, et al, Incremental value of high-sensitivity C-reactive protein and N-terminal pro-B-type natriuretic peptide for the prediction of postoperative cardiac events in noncardiac vascular surgery patients, Coron Artery Dis, vol. 20, pp. 219-24, Mar 24 2009.
    • (2009) Coron Artery Dis , vol.20 , pp. 219-224
    • Goei, D.1
  • 7
    • 1042299851 scopus 로고    scopus 로고
    • An investigation of the mechanisms of electronic sensing of protein adsorption on carbon nanotube devices
    • Chen R.J., Choi H.C., Bangsaruntip. S., Yenilmez E., Tang X., Qian Wang. Q., Chang Y.L., Dai.H., An Investigation of the Mechanisms of Electronic Sensing of Protein Adsorption on Carbon Nanotube Devices, J. Am. Chem. Soc, 2004; 126(5), p.1563-68.
    • (2004) J. Am. Chem. Soc , vol.126 , Issue.5 , pp. 1563-1568
    • Chen, R.J.1    Choi, H.C.2    Bangsaruntip, S.3    Yenilmez, E.4    Tang, X.5    Qian Wang, Q.6    Chang, Y.L.7    Dai, H.8
  • 8
    • 1042309421 scopus 로고    scopus 로고
    • Layered nanoparticle architectures on surfaces for sensing and electronic functionalities
    • M. Lieberman (Ed.) ACS Symposium Series Washington, D.C., U.S.A., Chapter 8
    • Willner, I., Shipway, A.N., and Willner, B., Layered Nanoparticle Architectures on Surfaces for Sensing and Electronic Functionalities. In Molecules as Components of Electronic Devices. M. Lieberman (Ed.) ACS Symposium Series. 2003. 844, Washington, D.C., U.S.A., Chapter 8: p. 88-105.
    • (2003) Molecules as Components of Electronic Devices , vol.844 , pp. 88-105
    • Willner, I.1    Shipway, A.N.2    Willner, B.3
  • 9
    • 0033199750 scopus 로고    scopus 로고
    • A porous silicon optical biosensor: Detection of reversible binding of IgG to a protein A-modified surface
    • P.S.
    • Dancil, K., P.S., Greiner, D.P., and Sailor, M.J., A porous silicon optical biosensor: detection of reversible binding of IgG to a protein A-modified surface. J. Am. Chem Soc., 1999. 121(34): p. 7925-30.
    • (1999) J. Am. Chem Soc. , vol.121 , Issue.34 , pp. 7925-7930
    • Dancil, K.1    Greiner, D.P.2    Sailor, M.J.3
  • 10
    • 1842790784 scopus 로고    scopus 로고
    • Electrochemical synthesis and impedance characterization of nanopatternedbiosensor substrate
    • Takhistov P., Electrochemical synthesis and impedance characterization of nanopatternedbiosensor substrate. Biosens Bioelectron. 2004. 9(11): p.1445-56.
    • (2004) Biosens Bioelectron , vol.9 , Issue.11 , pp. 1445-1456
    • Takhistov, P.1
  • 12
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Feb 8
    • Bland JM, and Altman DG, Statistical methods for assessing agreement between two methods of clinical measurement, Lancet, vol. 1, pp. 307-10, Feb 8 1986.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.