메뉴 건너뛰기




Volumn 5, Issue 1, 2012, Pages 63-70

Dose verification of IMRT by use of a COMPASS transmission detector

Author keywords

Compass transmission detector; Gamma analysis; IMRT dose verification; Quality assurance

Indexed keywords

ACCURACY; ARTICLE; CONTROLLED STUDY; DOSIMETRY; GAMMA RADIATION; INTENSITY MODULATED RADIATION THERAPY; INTERMETHOD COMPARISON; MATHEMATICAL COMPUTING; PRIORITY JOURNAL; RADIATION DEPTH DOSE; RADIATION DETECTOR; RADIATION DOSE; RADIATION DOSE DISTRIBUTION; RADIATION MEASUREMENT; VALIDATION PROCESS;

EID: 84858865013     PISSN: 18650333     EISSN: 18650341     Source Type: Journal    
DOI: 10.1007/s12194-011-0137-y     Document Type: Article
Times cited : (15)

References (17)
  • 3
    • 0036703563 scopus 로고    scopus 로고
    • Evaluation of kodak EDR2 film for dose verification of intensity modulated radiation therapy delivered by a static multileaf collimator
    • DOI 10.1118/1.1493781
    • Zhu XR, Jursinic PA, Grimm DF, Lopez F, Rownd JJ, Gillin MT. Evaluation of Kodak EDR2 film for dose verification of intensity modulated radiation therapy delivered by a static multileaf collimator. Med Phys. 2002;29:1687-92. (Pubitemid 35364203)
    • (2002) Medical Physics , vol.29 , Issue.8 , pp. 1687-1692
    • Zhu, X.R.1    Jursinic, P.A.2    Grimm, D.F.3    Lopez, F.4    Rownd, J.J.5    Gillin, M.T.6
  • 4
    • 0035192124 scopus 로고    scopus 로고
    • Comprehensive quality assurance for the delivery of intensity modulated radiotherapy with a multileaf collimator used in the dynamic mode
    • LoSasso T, Chui CS, Ling CC. Comprehensive quality assurance for the delivery of intensity modulated radiotherapy with a multileaf collimator used in the dynamic mode. Med Phys. 2001;28:2209-18.
    • (2001) Med Phys , vol.28 , pp. 2209-2218
    • LoSasso, T.1    Chui, C.S.2    Ling, C.C.3
  • 5
    • 1542603236 scopus 로고    scopus 로고
    • Evaluation of a 2D diode array for IMRT quality assurance
    • DOI 10.1016/j.radonc.2003.10.014, PII S0167814003004171
    • Létourneau D, Gulam M, Yan D, Oldham M, Wong JW. Evaluation of a 2D diode array for IMRT quality assurance. Radiother Oncol. 2004;70:199-206. (Pubitemid 38353020)
    • (2004) Radiotherapy and Oncology , vol.70 , Issue.2 , pp. 199-206
    • Letourneau, D.1    Gulam, M.2    Yan, D.3    Oldham, M.4    Wong, J.W.5
  • 6
    • 0037910445 scopus 로고    scopus 로고
    • A 2-D diode array and analysis software for verification of intensity modulated radiation therapy delivery
    • Jursinic PA, Nelms BE. A 2-D diode array and analysis software for verification of intensity modulated radiation therapy delivery. Med Phys. 2003;30:870-90.
    • (2003) Med Phys , vol.30 , pp. 870-890
    • Jursinic, P.A.1    Nelms, B.E.2
  • 7
    • 35649000354 scopus 로고    scopus 로고
    • Experimental investigation of the response of an amorphous silicon EPID to intensity modulated radiotherapy beams
    • DOI 10.1118/1.2789406
    • Greer PB, Vial P, Oliver L, Baldock C. Experimental investigation of the response of an amorphous silicon EPID to intensity modulated radiotherapy beams. Med Phys. 2007;34:4389-98. (Pubitemid 350029661)
    • (2007) Medical Physics , vol.34 , Issue.11 , pp. 4389-4398
    • Greer, P.B.1    Vial, P.2    Oliver, L.3    Baldock, C.4
  • 8
    • 50449096215 scopus 로고    scopus 로고
    • Use of a two-dimensional ionization chamber array for proton therapy beam quality assurance
    • Arjomandy B, Sahoo N, Ding X, Gillin M. Use of a two-dimensional ionization chamber array for proton therapy beam quality assurance. Med Phys. 2008;35:3889-94.
    • (2008) Med Phys , vol.35 , pp. 3889-3894
    • Arjomandy, B.1    Sahoo, N.2    Ding, X.3    Gillin, M.4
  • 9
    • 79551661964 scopus 로고    scopus 로고
    • Quality assurance of volumetric modulated arc therapy: Evaluation and comparison of different dosimetric systems
    • Masi L, Casamassima F, Doro R, Francescon P. Quality assurance of volumetric modulated arc therapy: evaluation and comparison of different dosimetric systems. Med Phys. 2011;38:612-21.
    • (2011) Med Phys , vol.38 , pp. 612-621
    • Masi, L.1    Casamassima, F.2    Doro, R.3    Francescon, P.4
  • 12
    • 80255134521 scopus 로고    scopus 로고
    • Patient-specific 3D pretreatment and potential 3D online dose verification of Monte Carlo-calculated IMRT prostate treatment plans
    • in press
    • Boggula R, Jahnke L, Wertz H, Lohr F, Wenz F. Patient-specific 3D pretreatment and potential 3D online dose verification of Monte Carlo-calculated IMRT prostate treatment plans. Int J Radiat Oncol Biol Phys (in press).
    • Int J Radiat Oncol Biol Phys
    • Boggula, R.1    Jahnke, L.2    Wertz, H.3    Lohr, F.4    Wenz, F.5
  • 17
    • 11244291999 scopus 로고    scopus 로고
    • Predicting energy response of radiographic film in a 6 MV x-ray beam using Monte Carlo calculated fluence and absorbed dose
    • DOI 10.1118/1.1812911
    • Palm A, Kirov AS, LoSasso T. Predicting energy response of radiographic film in a 6 MV x-ray beam using Monte Carlo calculated fluence spectra and absorbed dose. Med Phys. 2004;31:3168-78. (Pubitemid 40064968)
    • (2004) Medical Physics , vol.31 , Issue.12 , pp. 3168-3178
    • Palm, A.1    Kirov, A.S.2    LoSasso, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.