메뉴 건너뛰기




Volumn 56, Issue 4, 2012, Pages 532-534

Avoiding palatopharyngeal trauma during videolaryngoscopy: Do not forget the blind spots

Author keywords

[No Author keywords available]

Indexed keywords

ANESTHESIST; ENDOTRACHEAL INTUBATION; ENDOTRACHEAL TUBE; HUMAN; ILLUMINATION; LARYNGOSCOPE; LARYNGOSCOPY; LETTER; PALATOPHARYNGEAL INJURY; PHARYNX DISEASE; PRIORITY JOURNAL; RESPIRATORY TRACT MUCOSA; SOFT TISSUE INJURY; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; VIDEOLARYNGOSCOPY; VOCAL CORD;

EID: 84858707772     PISSN: 00015172     EISSN: 13996576     Source Type: Journal    
DOI: 10.1111/j.1399-6576.2011.02642.x     Document Type: Letter
Times cited : (30)

References (21)
  • 1
    • 33846605602 scopus 로고    scopus 로고
    • Complications and the use of the GlideScope
    • Cooper RM,. Complications and the use of the GlideScope. Can J Anaesth 2007; 54: 54-57.
    • (2007) Can J Anaesth , vol.54 , pp. 54-57
    • Cooper, R.M.1
  • 2
    • 36849079483 scopus 로고    scopus 로고
    • Soft palate perforation during orotracheal intubation facilitated by the GlideScope videolaryngoscope
    • Vincent RD, Wimberly MP, Brockwell RC, Magnuson JS,. Soft palate perforation during orotracheal intubation facilitated by the GlideScope videolaryngoscope. J Clin Anesth 2007; 19: 619-621.
    • (2007) J Clin Anesth , vol.19 , pp. 619-621
    • Vincent, R.D.1    Wimberly, M.P.2    Brockwell, R.C.3    Magnuson, J.S.4
  • 3
    • 34447628687 scopus 로고    scopus 로고
    • Perforation of the soft palate using the GlideScope videolaryngoscope
    • Cross P, Cytryn J, Cheng KK,. Perforation of the soft palate using the GlideScope videolaryngoscope. Can J Anaesth 2007; 54: 588-589.
    • (2007) Can J Anaesth , vol.54 , pp. 588-589
    • Cross, P.1    Cytryn, J.2    Cheng, K.K.3
  • 5
    • 34249000358 scopus 로고    scopus 로고
    • Penetrating injury of the soft palate during GlideScope intubation
    • Hsu W-T, Hsu S-C, Lee Y-L, Huang J-S, Chen C-L,. Penetrating injury of the soft palate during GlideScope intubation. Anesth Analg 2007; 104: 1609-1611.
    • (2007) Anesth Analg , vol.104 , pp. 1609-1611
    • Hsu, W.-T.1    Hsu, S.-C.2    Lee, Y.-L.3    Huang, J.-S.4    Chen, C.-L.5
  • 6
    • 34250768246 scopus 로고    scopus 로고
    • Pharyngeal injury related to GlideScope videolaryngoscope
    • Hirabayashi Y,. Pharyngeal injury related to GlideScope videolaryngoscope. Otolaryngol Head Neck Surg 2007; 137: 175-176.
    • (2007) Otolaryngol Head Neck Surg , vol.137 , pp. 175-176
    • Hirabayashi, Y.1
  • 7
    • 34249014023 scopus 로고    scopus 로고
    • Anterior tonsillar pillar perforation during GlideScope videolaryngoscopy
    • Malik AM, Frogel JK,. Anterior tonsillar pillar perforation during GlideScope videolaryngoscopy. Anesth Analg 2007; 104: 1610-1611.
    • (2007) Anesth Analg , vol.104 , pp. 1610-1611
    • Malik, A.M.1    Frogel, J.K.2
  • 8
    • 85045482339 scopus 로고    scopus 로고
    • Another complication associated with videolaryngoscopy GlideScope
    • Choo MKF, Yea VST, See JJ,. Another complication associated with videolaryngoscopy GlideScope. Can J Anaesth 2007; 54: 322-324.
    • (2007) Can J Anaesth , vol.54 , pp. 322-324
    • Choo, M.K.F.1    Yea, V.S.T.2    See, J.J.3
  • 9
    • 56649083451 scopus 로고    scopus 로고
    • Palatopharyngeal wall perforation GlideScope intubation
    • Leong WL, Lim Y, Sia ATH,. Palatopharyngeal wall perforation GlideScope intubation. Anaesth Intensive Care 2008; 36: 870-874.
    • (2008) Anaesth Intensive Care , vol.36 , pp. 870-874
    • Leong, W.L.1    Lim, Y.2    Sia, A.T.H.3
  • 10
    • 42549136074 scopus 로고    scopus 로고
    • Penetrating injury of the palatoglossal arch associated with use of the GlideScope videolaryngoscope in a flame burn patient
    • Hsu W-T, Tsao S-L, Chen K-Y, Chou W-K,. Penetrating injury of the palatoglossal arch associated with use of the GlideScope videolaryngoscope in a flame burn patient. Acta Anaesthesiol Taiwan 2008; 46: 39-41.
    • (2008) Acta Anaesthesiol Taiwan , vol.46 , pp. 39-41
    • Hsu, W.-T.1    Tsao, S.-L.2    Chen, K.-Y.3    Chou, W.-K.4
  • 11
    • 50149102820 scopus 로고    scopus 로고
    • Soft palate perforation during orotracheal intubation facilitated by the GlideScope videolaryngoscope
    • Manickam BP, Adhikary SD,. Soft palate perforation during orotracheal intubation facilitated by the GlideScope videolaryngoscope. J Clin Anesth 2008; 20: 401-402.
    • (2008) J Clin Anesth , vol.20 , pp. 401-402
    • Manickam, B.P.1    Adhikary, S.D.2
  • 12
    • 70349324612 scopus 로고    scopus 로고
    • Palatal perforation associated with McGrath videolaryngoscope
    • Williams D, Ball DR,. Palatal perforation associated with McGrath videolaryngoscope. Anaesthesia 2009; 64: 1144-1145.
    • (2009) Anaesthesia , vol.64 , pp. 1144-1145
    • Williams, D.1    Ball, D.R.2
  • 13
    • 77949467558 scopus 로고    scopus 로고
    • Maneuvers to prevent oropharyngeal injury during orotracheal intubation with the GlideScope videolaryngoscope
    • Dupanovic M,. Maneuvers to prevent oropharyngeal injury during orotracheal intubation with the GlideScope videolaryngoscope. J Clin Anesth 2010; 22: 152-154.
    • (2010) J Clin Anesth , vol.22 , pp. 152-154
    • Dupanovic, M.1
  • 14
    • 0025066338 scopus 로고
    • Anaesthetic morbidity from trauma to the uvula
    • Stubbing JF,. Anaesthetic morbidity from trauma to the uvula. Anaesthesia 1990; 45: 886-887.
    • (1990) Anaesthesia , vol.45 , pp. 886-887
    • Stubbing, J.F.1
  • 15
    • 0028857323 scopus 로고
    • Hypopharynx perforation by a transesophageal echocardiography probe
    • Spahn DR, Schmid S, Carrel T, Pasch T, Schmid ER,. Hypopharynx perforation by a transesophageal echocardiography probe. Anesthesiology 1995; 82: 581-583.
    • (1995) Anesthesiology , vol.82 , pp. 581-583
    • Spahn, D.R.1    Schmid, S.2    Carrel, T.3    Pasch, T.4    Schmid, E.R.5
  • 18
    • 70349330258 scopus 로고    scopus 로고
    • Randomised comparison of Pentax AirwayScope and Glidescope for tracheal intubation in patients with normal airway anatomy
    • Teoh WHL, Shah MK, Sia ATH,. Randomised comparison of Pentax AirwayScope and Glidescope for tracheal intubation in patients with normal airway anatomy. Anaesthesia 2009; 64: 1125-1129.
    • (2009) Anaesthesia , vol.64 , pp. 1125-1129
    • Teoh, W.H.L.1    Shah, M.K.2    Sia, A.T.H.3
  • 19
    • 78049491780 scopus 로고    scopus 로고
    • TM, Glidescope vs the Macintosh laryngoscope for tracheal intubation
    • TM, Glidescope vs the Macintosh laryngoscope for tracheal intubation. Anaesthesia 2010; 65: 1126-1132.
    • (2010) Anaesthesia , vol.65 , pp. 1126-1132
    • Teoh, W.H.L.1    Saxena, S.2    Shah, M.K.3    Sia, A.T.H.4
  • 20
    • 46749141257 scopus 로고    scopus 로고
    • Airway trauma caused by the Airtraq laryngoscope
    • Holst B, Hodzovic I, Francis V,. Airway trauma caused by the Airtraq laryngoscope. Anaesthesia 2008; 63: 889-890.
    • (2008) Anaesthesia , vol.63 , pp. 889-890
    • Holst, B.1    Hodzovic, I.2    Francis, V.3
  • 21


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.