메뉴 건너뛰기




Volumn 31, Issue 4, 2012, Pages 450-453

Posterior dislocation and immediate retrieval of a descemet stripping automated endothelial keratoplasty graft

Author keywords

Descemet stripping automated endothelial keratoplasty; graft dislocation

Indexed keywords

ADULT; ARTICLE; CASE REPORT; DESCEMET STRIPPING ENDOTHELIAL KERATOPLASTY; FORCEPS; HUMAN; INTRAOPERATIVE PERIOD; LENS IMPLANT; MALE; PARACENTESIS; PRIORITY JOURNAL; PROSTHESIS FAILURE; ULTRASOUND; VITRECTOMY;

EID: 84858705444     PISSN: 02773740     EISSN: 15364798     Source Type: Journal    
DOI: 10.1097/ICO.0b013e31823f76d5     Document Type: Article
Times cited : (10)

References (11)
  • 1
    • 33751110218 scopus 로고    scopus 로고
    • Descemet-stripping automated endothelial keratoplasty
    • DOI 10.1097/01.ico.0000214224.90743.01, PII 0000322620060900000005
    • Gorovoy MS. Descemet-stripping automated endothelial keratoplasty. Cornea. 2006;25:886-889. (Pubitemid 44763845)
    • (2006) Cornea , vol.25 , Issue.8 , pp. 886-889
    • Gorovoy, M.S.1
  • 2
    • 69249208489 scopus 로고    scopus 로고
    • Descemet's stripping endothelial keratoplasty: Safety and outcomes: A report by the american academy of ophthalmology
    • Lee W, Jacobs DS, Musch DC, et al. Descemet's stripping endothelial keratoplasty: safety and outcomes: a report by the American Academy of Ophthalmology. Ophthalmology. 2009;116:1818-1830.
    • (2009) Ophthalmology. , vol.116 , pp. 1818-1830
    • Lee, W.1    Jacobs, D.S.2    Musch, D.C.3
  • 3
    • 22644443452 scopus 로고    scopus 로고
    • Descemet's stripping with endothelial keratoplasty in 50 eyes: A refractive neutral corneal transplant
    • Price FW Jr, Price MO. Descemet's stripping with endothelial kerato-plasty in 50 eyes: a refractive neutral corneal transplant. J Refract Surg. 2005;21:339-345. (Pubitemid 41026058)
    • (2005) Journal of Refractive Surgery , vol.21 , Issue.4 , pp. 339-345
    • Price Jr., F.W.1    Price, M.O.2
  • 4
    • 33646036099 scopus 로고    scopus 로고
    • Descemet's stripping with endothelial kerato-plasty in 200 eyes: Early challenges and techniques to enhance donor adherence
    • Price FW Jr, Price MO. Descemet's stripping with endothelial kerato-plasty in 200 eyes: early challenges and techniques to enhance donor adherence. J Cataract Refract Surg. 2006;32:411-418.
    • (2006) J Cataract Refract Surg. , vol.32 , pp. 411-418
    • Price Jr., F.W.1    Price, M.O.2
  • 5
    • 42649130361 scopus 로고    scopus 로고
    • Endothelial Cell Loss after Descemet Stripping with Endothelial Keratoplasty. Influencing Factors and 2-Year Trend
    • DOI 10.1016/j.ophtha.2007.06.033, PII S0161642007007300
    • Price MO, Price FW Jr. Endothelial cell loss after Descemet stripping with endothelial keratoplasty: influencing factors and 2-year trend. Ophthalmology. 2008;115:857-865. (Pubitemid 351602289)
    • (2008) Ophthalmology , vol.115 , Issue.5 , pp. 857-865
    • Price, M.O.1    Price Jr., F.W.2
  • 6
    • 34548315915 scopus 로고    scopus 로고
    • Slit-lamp technique of draining interface fluid following Descemet's stripping endothelial keratoplasty
    • DOI 10.1136/bjo.2007.121012
    • Srinivasan S, Rootman DS. Slit-lamp technique of draining interface fluid following Descemet's stripping endothelial keratoplasty. Br J Ophthalmol. 2007;91:1202-1205. (Pubitemid 47344898)
    • (2007) British Journal of Ophthalmology , vol.91 , Issue.9 , pp. 1202-1205
    • Srinivasan, S.1    Rootman, D.S.2
  • 7
    • 50249105211 scopus 로고    scopus 로고
    • Complications of descemet's stripping with automated endothelial keratoplasty: Survey of 118 eyes at one institute
    • Suh LH, Yoo SH, Deobhakta A, et al. Complications of Descemet's stripping with automated endothelial keratoplasty: survey of 118 eyes at One Institute. Ophthalmology. 2008;115:1517-1524.
    • (2008) Ophthalmology. , vol.115 , pp. 1517-1524
    • Suh, L.H.1    Yoo, S.H.2    Deobhakta, A.3
  • 8
    • 70449627040 scopus 로고    scopus 로고
    • Visually significant and nonsignificant complications arising from descemet stripping automated endothelial keratoplasty
    • Shih CY, Ritterband DC, Rubino S, et al. Visually significant and nonsignificant complications arising from Descemet stripping automated endothelial keratoplasty. Am J Ophthalmol. 2009;148:837-843.
    • (2009) Am J Ophthalmol. , vol.148 , pp. 837-843
    • Shih, C.Y.1    Ritterband, D.C.2    Rubino, S.3
  • 9
    • 62149124095 scopus 로고    scopus 로고
    • Posterior lamellar disc dislocation into the vitreous cavity during descemet stripping automated endothelial keratoplasty
    • Grueterich M, Messmer E, Kampik A. Posterior lamellar disc dislocation into the vitreous cavity during Descemet stripping automated endothelial keratoplasty. Cornea. 2009;28:93-96.
    • (2009) Cornea. , vol.28 , pp. 93-96
    • Grueterich, M.1    Messmer, E.2    Kampik, A.3
  • 10
    • 78149286117 scopus 로고    scopus 로고
    • Posterior dislocation of descemet stripping automated endothelial keratoplasty graft can lead to retinal detachment
    • Singh A, Gupta A, Stewart JM. Posterior dislocation of Descemet stripping automated endothelial keratoplasty graft can lead to retinal detachment. Cornea. 2010;29:1284-1286.
    • (2010) Cornea. , vol.29 , pp. 1284-1286
    • Singh, A.1    Gupta, A.2    Stewart, J.M.3
  • 11
    • 78751641220 scopus 로고    scopus 로고
    • Descemet stripping automated endothelial keratoplasty with a graft insertion device: Surgical technique and early clinical results
    • Khor W, Mehta J, Tan D. Descemet stripping automated endothelial keratoplasty with a graft insertion device: surgical technique and early clinical results. Am J Ophthalmol. 2011;151:223-232.
    • (2011) Am J Ophthalmol. , vol.151 , pp. 223-232
    • Khor, W.1    Mehta, J.2    Tan, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.