메뉴 건너뛰기




Volumn 82, Issue 5, 2012, Pages

A comparison of four indices for combining distance and dose differences

Author keywords

Box index; Dose distribution comparison; Gamma index; ICRU 83; Kappa index

Indexed keywords

BOX INDEX; DOSE-DISTRIBUTION COMPARISON; GAMMA INDEX; ICRU 83; KAPPA INDEX;

EID: 84858699120     PISSN: 03603016     EISSN: 1879355X     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2011.11.009     Document Type: Article
Times cited : (14)

References (10)
  • 1
    • 0031861573 scopus 로고    scopus 로고
    • A technique for the quantitative evaluation of dose distributions
    • DOI 10.1118/1.598248
    • Low DA, Harms WB, Mutic S, Purdy JA. A technique for the quantitative evaluation of dose distributions. Med Phys 1998;25:656-661. (Pubitemid 28234885)
    • (1998) Medical Physics , vol.25 , Issue.5 , pp. 656-661
    • Low, D.A.1    Harms, W.B.2    Mutic, S.3    Purdy, J.A.4
  • 2
    • 7844245059 scopus 로고    scopus 로고
    • A software tool for the quantitative evaluation of 3D dose calculation algorithms
    • DOI 10.1118/1.598363
    • Harms WB, Low DA, Wong JW, Purdy JA. A software tool for the quantitative evaluation of 3D dose calculation algorithms. Med Phys 1998;25:1830-1836. (Pubitemid 28485203)
    • (1998) Medical Physics , vol.25 , Issue.10 , pp. 1830-1836
    • Harms Sr., W.B.1    Low, D.A.2    Wong, J.W.3    Purdy, J.A.4
  • 5
    • 84858700409 scopus 로고    scopus 로고
    • ICRU Report 83: Prescribing, Recording and Reporting Photon-Beam Intensity-Modulated Radiation Therapy (IMRT)
    • International Commission on Radiation Units & Measurements
    • International Commission on Radiation Units & Measurements. ICRU Report 83: Prescribing, Recording and Reporting Photon-Beam Intensity-Modulated Radiation Therapy (IMRT). J ICRU 2010;10: 1-92.
    • (2010) J ICRU , vol.10 , pp. 1-92
  • 6
    • 0141520680 scopus 로고    scopus 로고
    • Evaluation of the gamma dose distribution comparison method
    • DOI 10.1118/1.1598711
    • Low DA, Dempsey JF. Evaluation of the gamma dose distribution comparison method. Med Phys 2003;30:2455-2464. (Pubitemid 37129751)
    • (2003) Medical Physics , vol.30 , Issue.9 , pp. 2455-2464
    • Low, D.A.1    Dempsey, J.F.2
  • 7
    • 40049094995 scopus 로고    scopus 로고
    • Geometric interpretation of the gamma dose distribution comparison technique: Interpolation-free calculation
    • DOI 10.1118/1.2836952
    • Ju T, Simpson T, Deasy JO, Low DA. Geometric interpretation of the gamma dose distribution comparison technique: interpolation-free calculation. Med Phys 2008;35:879-887. (Pubitemid 351322669)
    • (2008) Medical Physics , vol.35 , Issue.3 , pp. 879-887
    • Ju, T.1    Simpson, T.2    Deasy, J.O.3    Low, D.A.4
  • 8
    • 84858705581 scopus 로고    scopus 로고
    • An independent dose calculation program for the checking of TomoTherapy plans
    • Thomas S, Eyre K, Tudor G, Fairfoul J. An independent dose calculation program for the checking of TomoTherapy plans. Radiother Oncol 2011;99(Suppl. 1):S153.
    • (2011) Radiother Oncol , vol.99 , Issue.SUPPL. 1
    • Thomas, S.1    Eyre, K.2    Tudor, G.3    Fairfoul, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.