메뉴 건너뛰기




Volumn , Issue , 2011, Pages 2036-2038

Front-end electronics for the Scalable Readout System of RD51

Author keywords

[No Author keywords available]

Indexed keywords

GAS DETECTORS; HIGH ENERGY PHYSICS; READOUT SYSTEMS;

EID: 84858691867     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2011.6154414     Document Type: Conference Paper
Times cited : (83)

References (6)
  • 1
    • 0034593606 scopus 로고    scopus 로고
    • The APV25 0. 25 μm CMOS readout chip for the CMS tracker
    • IEEE
    • Raymond, M et al., "The APV25 0. 25 μm CMOS readout chip for the CMS tracker," Nuclear Science Symposium Conference Record, 2000 IEEE, vol.2, pp.9/113-9/118
    • (2000) Nuclear Science Symposium Conference Record , vol.2
    • Raymond, M.1
  • 2
    • 0942288154 scopus 로고    scopus 로고
    • Beetle - A radiation hard readout chip for the LHCb experiment
    • M. Agari et al., "Beetle - a radiation hard readout chip for the LHCb experiment", Nucl. Instrum. Meth., A 518, Pages 468-469, 2004
    • (2004) Nucl. Instrum. Meth., A , vol.518 , pp. 468-469
    • Agari, M.1
  • 3
    • 79960315453 scopus 로고    scopus 로고
    • VFAT2: A front-end system on chip providing fast trigger information, digitized data storage and formatting for the charge sensitive readout of multi-channel silicon and gas particle detectors
    • P.Aspell et al., "VFAT2: A front-end system on chip providing fast trigger information, digitized data storage and formatting for the charge sensitive readout of multi-channel silicon and gas particle detectors.", Proceedings of TWEPP 2007, p.292
    • Proceedings of TWEPP 2007 , pp. 292
    • Aspell, P.1
  • 4
    • 0036815755 scopus 로고    scopus 로고
    • Medipix2: A 64-k pixel readout chip with 55-μm square elements working in single photon counting mode
    • DOI 10.1109/TNS.2002.803788
    • Llopart, X. et al., "Medipix2: A 64-k pixel readout chip with 55-μm square elements working in single photon counting mode," Nuclear Science, IEEE Transactions on, vol.49, no.5, pp. 2279-2283, Oct 2002 (Pubitemid 35443088)
    • (2002) IEEE Transactions on Nuclear Science , vol.49 I , Issue.5 , pp. 2279-2283
    • Llopart, X.1    Campbell, M.2    Dinapoli, R.3    San, S.D.4    Pernigotti, E.5
  • 5
    • 84858669163 scopus 로고    scopus 로고
    • A Small Muon Tomography Station with GEM Detectors
    • submitted to
    • M. Hohlmann et al., "A Small Muon Tomography Station with GEM Detectors", submitted to IEEE NSS/MIC 2011
    • IEEE NSS/MIC 2011
    • Hohlmann, M.1
  • 6
    • 84858655760 scopus 로고    scopus 로고
    • The Front-End Concentrator card for the RD-51 Scalable Readout System
    • accepted for publication in
    • J. Toledo et al., "The Front-End Concentrator card for the RD-51 Scalable Readout System", accepted for publication in JINST
    • JINST
    • Toledo, J.1