메뉴 건너뛰기




Volumn 1, Issue 2, 2011, Pages 143-150

Optimization methods for improving the performance of heart rate detection by a wearable ECG system during high-intensity exercise

Author keywords

Adaptive filter; High intensity exercise; Mathematical morphology operator; Skin hydration; Textile electrode; Wavelet; Wearable

Indexed keywords


EID: 84858595279     PISSN: 20939868     EISSN: 2093985X     Source Type: Journal    
DOI: 10.1007/s13534-011-0023-x     Document Type: Article
Times cited : (4)

References (17)
  • 1
    • 77953175200 scopus 로고    scopus 로고
    • Recent advances in free-living physical activity monitoring: a review
    • Andre D, Wolf DL. Recent advances in free-living physical activity monitoring: a review. J Diabetes Sci Tech. 2007; 5: 760-767.
    • (2007) J Diabetes Sci Tech. , vol.5 , pp. 760-767
    • Andre, D.1    Wolf, D.L.2
  • 2
    • 57749177971 scopus 로고    scopus 로고
    • Textile-structured electrodes for electrocardiogram
    • Xu PJ, Zhang H, Tao XM. Textile-structured electrodes for electrocardiogram. Text Progr. 2008; 40: 183-213.
    • (2008) Text Progr. , vol.40 , pp. 183-213
    • Xu, P.J.1    Zhang, H.2    Tao, X.M.3
  • 3
    • 0029974333 scopus 로고    scopus 로고
    • The origin of skin-stretch-caused motion artifacts under electrodes
    • de Talhouet H, Webster JG. The origin of skin-stretch-caused motion artifacts under electrodes. Physiol Meas. 1996; 17: 81-93.
    • (1996) Physiol Meas. , vol.17 , pp. 81-93
    • de Talhouet, H.1    Webster, J.G.2
  • 5
    • 34047106684 scopus 로고    scopus 로고
    • Measurement of noise and impedance of dry and wet textile electrodes, and textile electrodes with hydrogel
    • Puurtinen MM, Komulainen SM, Kauppinen PK. Measurement of noise and impedance of dry and wet textile electrodes, and textile electrodes with hydrogel. Conf Proc IEEE Eng Med Biol Soc. 2006; 1: 6012-6015.
    • (2006) Conf Proc IEEE Eng Med Biol Soc. , vol.1 , pp. 6012-6015
    • Puurtinen, M.M.1    Komulainen, S.M.2    Kauppinen, P.K.3
  • 9
    • 68449087485 scopus 로고    scopus 로고
    • QRS detection based on multiscale mathematical morphology for wearable ECG devices in body area networks
    • Zhang F, Lian Y. QRS detection based on multiscale mathematical morphology for wearable ECG devices in body area networks. IEEE Trans Biomed Circ Syst. 2009; 3: 220-228.
    • (2009) IEEE Trans Biomed Circ Syst. , vol.3 , pp. 220-228
    • Zhang, F.1    Lian, Y.2
  • 11
    • 0021892137 scopus 로고
    • A real time QRS detection algorithm
    • Pan J, Tompkins WJ. A real time QRS detection algorithm. IEEE T Bio-Med Eng. 1985; 32: 230-236.
    • (1985) IEEE T Bio-Med Eng. , vol.32 , pp. 230-236
    • Pan, J.1    Tompkins, W.J.2
  • 12
    • 0028960610 scopus 로고
    • Detection of ECG characteristic points using wavelet transforms
    • Li C, Zheng C, Tai C. Detection of ECG characteristic points using wavelet transforms. IEEE T Bio-Med Eng. 1995; 42: 21-28.
    • (1995) IEEE T Bio-Med Eng. , vol.42 , pp. 21-28
    • Li, C.1    Zheng, C.2    Tai, C.3
  • 15
    • 38049013310 scopus 로고    scopus 로고
    • Robust heart rate estimation from multiple asynchronous noisy sources using signal quality indices and a Kalman filter
    • Li Q, Mark RG, Clifford GD. Robust heart rate estimation from multiple asynchronous noisy sources using signal quality indices and a Kalman filter. Physiol Meas. 2008; 29: 15-32.
    • (2008) Physiol Meas. , vol.29 , pp. 15-32
    • Li, Q.1    Mark, R.G.2    Clifford, G.D.3
  • 17
    • 84875568817 scopus 로고    scopus 로고
    • The MIT-BIH noise stress test database
    • The MIT-BIH noise stress test database. (http://www. physionet. org/physiobank/database/nstdb/).


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.