메뉴 건너뛰기




Volumn 35, Issue 3, 2012, Pages 554-561

Evaluation of methanol/activated carbons for thermally driven chillers, part II: The energy balance model

Author keywords

Activated carbon; Adsorption; Chilling; COP; Energy balance; Methanol

Indexed keywords

ABSORPTION CHILLERS; ADSORPTION CHILLER; ANALYTICAL EQUATIONS; COP; ENERGY BALANCE MODELS; ISOBARIC PROCESS; ISOTHERMAL DESORPTION; MATERIAL DATA; OPERATION TEMPERATURE; PHYSICAL PARAMETERS; STATIC PARAMETERS; THERMALLY DRIVEN CHILLERS; WORKING PAIR;

EID: 84858451438     PISSN: 01407007     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrefrig.2011.03.014     Document Type: Article
Times cited : (24)

References (20)
  • 1
    • 66549127352 scopus 로고    scopus 로고
    • Optimal adsorbent for adsorptive heat transformers: Dynamic considerations
    • 10.1016/j.ijrefrig.2009.01.022
    • Y.I. Aristov Optimal adsorbent for adsorptive heat transformers: dynamic considerations Int. J. Refrigeration 32 2009 675 686 10.1016/j.ijrefrig.2009.01. 022
    • (2009) Int. J. Refrigeration , vol.32 , pp. 675-686
    • Aristov, Y.I.1
  • 2
    • 0029514579 scopus 로고
    • Experimental investigation of a silica gel-water adsorption refrigeration cycle - The influence of operation conditions on cooling output and COP
    • E.E. Boelman, B.B. Saha, and T. Kashiwagi Experimental investigation of a silica gel-water adsorption refrigeration cycle - the influence of operation conditions on cooling output and COP ASHRAE Transactions 101 2 1995 358 366
    • (1995) ASHRAE Transactions , vol.101 , Issue.2 , pp. 358-366
    • Boelman, E.E.1    Saha, B.B.2    Kashiwagi, T.3
  • 3
    • 0029250739 scopus 로고
    • Reversible adsorption heat pump: A thermodynamic model
    • G. Cacciola, and G. Restuccia Reversible adsorption heat pump: a thermodynamic model Int. J. Refrigeration 18 2 1995 100 106
    • (1995) Int. J. Refrigeration , vol.18 , Issue.2 , pp. 100-106
    • Cacciola, G.1    Restuccia, G.2
  • 4
    • 33646529084 scopus 로고    scopus 로고
    • The influence of periodic operation on the characteristics of adsorption devices
    • 10.1016/j.enconman.2005.12.021
    • B. Cerkvenik, and F. Ziegler The influence of periodic operation on the characteristics of adsorption devices Energ. Convers. Manag. 47 2006 2020 2033 10.1016/j.enconman.2005.12.021
    • (2006) Energ. Convers. Manag. , vol.47 , pp. 2020-2033
    • Cerkvenik, B.1    Ziegler, F.2
  • 5
    • 0035452574 scopus 로고    scopus 로고
    • Influence of adsorption cycle limitations on the system performance
    • DOI 10.1016/S0140-7007(00)00075-X, PII S014070070000075X
    • B. Cerkvenik, A. Poredoš, and F. Ziegler Influence of adsorption cycle limitations on the system performance Int. J. Refrigeration 24 2001 475 485 (Pubitemid 32640116)
    • (2001) International Journal of Refrigeration , vol.24 , Issue.6 , pp. 475-485
    • Cerkvenik, B.1    Poredos, A.2    Ziegler, F.3
  • 6
    • 0242426474 scopus 로고    scopus 로고
    • Transient modeling of a two-bed silica gel-water adsorption chiller
    • DOI 10.1016/j.ijheatmasstransfer.2003.08.010
    • H.T. Chua, K.C. Ng, W. Wang, C. Yap, and X.L. Wang Transient modeling of a two-bed silica gel-water adsorption chiller Int. J. Heat Mass Transf. 47 4 February 2004 659 669 10.1016/j.ijheatmasstransfer.2003.08.010 (Pubitemid 37396188)
    • (2004) International Journal of Heat and Mass Transfer , vol.47 , Issue.4 , pp. 659-669
    • Chua, H.T.1    Ng, K.C.2    Wang, W.3    Yap, C.4    Wang, X.L.5
  • 7
    • 0035427766 scopus 로고    scopus 로고
    • Simulation of a continuous multiple-bed regenerative adsorption cycle
    • DOI 10.1016/S0140-7007(00)00026-8, PII S0140700700000268
    • R.E. Critoph Simulation of a continuous multiple-bed regenerative adsorption cycle Int. J. Refrigeration 24 5 August 2001 428 437 10.1016/S0140-7007(00)00026-8 (Pubitemid 32474183)
    • (2001) International Journal of Refrigeration , vol.24 , Issue.5 , pp. 428-437
    • Critoph, R.E.1
  • 8
    • 60949102613 scopus 로고    scopus 로고
    • Zeolite synthesised on copper foam for adsorption chillers: A mathematical model
    • 10.1016/j.micromeso.2008.12.011
    • A. Freni, L. Bonaccorsi, E. Proverbio, G. Maggio, and G. Restuccia Zeolite synthesised on copper foam for adsorption chillers: a mathematical model Microporous Mesoporous Mater. 120 3 15 April 2009 402 409 10.1016/j.micromeso. 2008.12.011
    • (2009) Microporous Mesoporous Mater. , vol.120 , Issue.3 , pp. 402-409
    • Freni, A.1    Bonaccorsi, L.2    Proverbio, E.3    Maggio, G.4    Restuccia, G.5
  • 9
    • 33646536316 scopus 로고    scopus 로고
    • A dynamic model of heat and mass transfer in a double-bed adsorption machine with internal heat recovery
    • G. Maggio, A. Freni, and G. Restuccia A dynamic model of heat and mass transfer in a double-bed adsorption machine with internal heat recovery Int. J. Refrigeration 29 4 June 2006 589 600
    • (2006) Int. J. Refrigeration , vol.29 , Issue.4 , pp. 589-600
    • Maggio, G.1    Freni, A.2    Restuccia, G.3
  • 11
    • 74549139314 scopus 로고    scopus 로고
    • Effect of residual gas on the dynamics of water adsorption under isobaric stages of adsorption heat pumps: Mathematical modelling
    • 10.1016/j.ijheatmasstransfer.2009.12.040
    • B.N. Okunev, A.P. Gromov, V.L. Zelenko, I.S. Glaznev, D.S. Ovoshchnikov, L.I. Heifets, and Yu.I. Aristov Effect of residual gas on the dynamics of water adsorption under isobaric stages of adsorption heat pumps: mathematical modelling Int. J. Heat and Mass Transf. 53 7-8 March 2010 1283 1289 10.1016/j.ijheatmasstransfer.2009.12.040
    • (2010) Int. J. Heat and Mass Transf. , vol.53 , Issue.78 , pp. 1283-1289
    • Okunev, B.N.1    Gromov, A.P.2    Zelenko, V.L.3    Glaznev, I.S.4    Ovoshchnikov, D.S.5    Heifets, L.I.6    Aristov, Yu.I.7
  • 12
    • 0029545777 scopus 로고
    • Computer simulation of a silica gel-water adsorption refrigeration cycle - The influence of operating conditions on cooling output and COP
    • B.B. Saha, E.C. Boelman, and T. Kashiwagi Computer simulation of a silica gel-water adsorption refrigeration cycle - the influence of operating conditions on cooling output and COP ASHRAE Transactions 101 2 1995 348 357
    • (1995) ASHRAE Transactions , vol.101 , Issue.2 , pp. 348-357
    • Saha, B.B.1    Boelman, E.C.2    Kashiwagi, T.3
  • 14
    • 67349090650 scopus 로고    scopus 로고
    • Modelling of an adsorption chiller for dynamic system simulation
    • Progress in Sorptive Cooling Systems
    • M. Schicktanz, and T. Núñez Modelling of an adsorption chiller for dynamic system simulation Int. J. Refrigeration 32 4 June 2009 588 595 Progress in Sorptive Cooling Systems
    • (2009) Int. J. Refrigeration , vol.32 , Issue.4 , pp. 588-595
    • Schicktanz, M.1    Núñez, T.2
  • 17
    • 67949099057 scopus 로고    scopus 로고
    • Carbon-ammonia pairs for adsorption refrigeration applications: Ice making, air conditioning and heat pumping
    • Z. Tamainot-Telto, S.J. Metcalf, R.E. Critoph, Y. Zhong, and R. Thorpe Carbon-ammonia pairs for adsorption refrigeration applications: ice making, air conditioning and heat pumping Int. J. Refrigeration 32 2009 1212 1229
    • (2009) Int. J. Refrigeration , vol.32 , pp. 1212-1229
    • Tamainot-Telto, Z.1    Metcalf, S.J.2    Critoph, R.E.3    Zhong, Y.4    Thorpe, R.5
  • 18
    • 0036640869 scopus 로고    scopus 로고
    • When do thin zeolite layers and a large void volume in the adsorber limit the performance of adsorption heat pumps?
    • DOI 10.1016/S1387-1811(02)00355-4, PII S1387181102003554
    • M. Tatlier, and A. Erdem-Senatalar When do thin zeolite layers and a large void volume in the adsorber limit the performance of adsorption heat pumps? Microporous Mesoporous Mater. 54 1-2 1 July 2002 89 96 10.1016/S1387-1811(02)00355-4 (Pubitemid 34793950)
    • (2002) Microporous and Mesoporous Materials , vol.54 , Issue.1-2 , pp. 89-96
    • Tatler, M.1    Erdem-enatalar, A.2
  • 19
    • 77955665986 scopus 로고    scopus 로고
    • Modelling of an adsorption system driven by engine waste heat for truck cabin A/C. Performance estimation for a standard driving cycle
    • 10.1016/j.applthermaleng.2010.04.005
    • M. Verde, L. Cortés, J.M. Corberán, A. Sapienza, S. Vasta, and G. Restuccia Modelling of an adsorption system driven by engine waste heat for truck cabin A/C. Performance estimation for a standard driving cycle Appl. Therm. Eng. 2010 10.1016/j.applthermaleng.2010.04.005
    • (2010) Appl. Therm. Eng.
    • Verde, M.1    Cortés, L.2    Corberán, J.M.3    Sapienza, A.4    Vasta, S.5    Restuccia, G.6
  • 20
    • 27744475518 scopus 로고    scopus 로고
    • Increase of the efficiency of the heat transfer phase in solid sorption or reaction systems
    • DOI 10.1016/j.ijthermalsci.2005.07.007, PII S1290072905002176
    • F. Ziegler, and P. Satzger Increase of the efficiency of the heat transfer phase in solid sorption or reaction systems Int. J. Therm. Sci. 44 2005 1115 1122 10.1016/j.ijthermalsci.2005.07.007 (Pubitemid 41606858)
    • (2005) International Journal of Thermal Sciences , vol.44 , Issue.12 , pp. 1115-1122
    • Ziegler, F.1    Satzger, P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.