Volumn 47, Issue 8, 2011, Pages 72-74

Characteristics and applications of GIL and GIS bus

Author keywords

Application; GIL; GIS bus

Indexed keywords


EID: 84858404850     PISSN: 10011609     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (11)

References (13)
  • 1
    • 84858431661 scopus 로고    scopus 로고
    • Specification for gas insulated metal enclosed transmission line
    • DL/T 978-2005
    • DL/T 978-2005. Specification for gas insulated metal enclosed transmission line[S].
  • 2
    • 84858412910 scopus 로고    scopus 로고
    • Gas insulated metal enclsed switchgear for rated voltages of 72.5 kV and above
    • GB 7674-1997
    • GB 7674-1997. Gas insulated metal enclsed switchgear for rated voltages of 72.5 kV and above[S].
  • 4
    • 67649488740 scopus 로고    scopus 로고
    • Questions to be considered for using 750 kV gil at Laxiwa hydroelectric power station
    • RUAN Quan-rong, SHI Wei, SANG Zhi-qiang. Questions to be considered for using 750 kV gil at Laxiwa hydroelectric power station[J]. High Voltage Apparatus, 2003, 39(4): 66-69.
    • (2003) High Voltage Apparatus , vol.39 , Issue.4 , pp. 66-69
    • Ruan, Q.-R.1    Shi, W.2    Sang, Z.-Q.3
  • 5
    • 84863338467 scopus 로고    scopus 로고
    • Defect analysis of the 750 kV GIS busbar tube of the Lanzhoudong substation
    • LI Hai-bo, WAN Rong-xing, FANG Yong. Defect analysis of the 750 kV GIS busbar tube of the Lanzhoudong substation[J]. High Voltage Apparatus, 2010, 46(11): 12-15.
    • (2010) High Voltage Apparatus , vol.46 , Issue.11 , pp. 12-15
    • Li, H.-B.1    Wan, R.-X.2    Fang, Y.3
  • 6
    • 84863338533 scopus 로고    scopus 로고
    • Electric field optimization of the supporting insulator of 500 kV DC GIL
    • JIA Zhi-jie, LI Jian-ming, LI Jia, et al. Electric field optimization of the supporting insulator of 500 kV DC GIL[J]. High Voltage Apparatus, 2010, 46(6): 18-21.
    • (2010) High Voltage Apparatus , vol.46 , Issue.6 , pp. 18-21
    • Jia, Z.-J.1    Li, J.-M.2    Li, J.3
  • 7
    • 84863338269 scopus 로고    scopus 로고
    • Research on arrangement of GIL compartment in high drop vertical shaft
    • RUAN Quan-rong, LI Hui, LIU Guo-feng, et al. Research on arrangement of GIL compartment in high drop vertical shaft[J]. High Voltage Apparatus, 2010, 46(8): 52-55.
    • (2010) High Voltage Apparatus , vol.46 , Issue.8 , pp. 52-55
    • Ruan, Q.-R.1    Li, H.2    Liu, G.-F.3
  • 11
    • 84858393200 scopus 로고    scopus 로고
    • 6-gas handling and measuring devices
    • DILO
    • 6-gas handling and measuring devices[B]. 2008.
    • (2008)
  • 12
    • 84858423046 scopus 로고    scopus 로고
    • Rule of site high voltage test for Gas insulated metal enclsed switchgear
    • GB 7674-1997
    • GB 7674-1997. Rule of site high voltage test for Gas insulated metal enclsed switchgear[S].
  • 13
    • 84976504974 scopus 로고    scopus 로고
    • 800 kV gas insulated transmission line in a vertical shaft
    • MA Zhong-ming, LI Liu-ling, BOWMAN G, et al. 800 kV gas insulated transmission line in a vertical shaft[J]. Electric Power, 2008, 41(8): 42-45.
    • (2008) Electric Power , vol.41 , Issue.8 , pp. 42-45
    • Ma, Z.-M.1    Li, L.-L.2    Bowman, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.