메뉴 건너뛰기




Volumn 54, Issue 18, 2009, Pages 3160-3166

Cupric ion release and cytotoxicity for Yuangong Cu-IUDs and the release behavior of indomethacin for medicated 220 Cu-IUD

Author keywords

Cytotoxicity; Indomethacin; Release rate; Uneven corrosion; Yuangong Cu IUD

Indexed keywords


EID: 84858340862     PISSN: 10016538     EISSN: 18619541     Source Type: Journal    
DOI: 10.1007/s11434-009-0258-4     Document Type: Article
Times cited : (11)

References (24)
  • 1
    • 34248663229 scopus 로고    scopus 로고
    • Worldwide use of intrauterine devices for contraception
    • d'Arcangues C. Worldwide use of intrauterine devices for contraception. Contraception, 2007, 75: 2-7
    • (2007) Contraception , vol.75 , pp. 2-7
    • D'Arcangues, C.1
  • 2
    • 40649115396 scopus 로고    scopus 로고
    • Investigation of the release behavior of cupric ion for three types of Cu-IUDs and indomethacin for medicated Cu-IUD in simulated uterine fluid
    • Liang J, Li Y. Investigation of the release behavior of cupric ion for three types of Cu-IUDs and indomethacin for medicated Cu-IUD in simulated uterine fluid. Contraception, 2008, 77: 299-302
    • (2008) Contraception , vol.77 , pp. 299-302
    • Liang, J.1    Li, Y.2
  • 3
    • 10044257748 scopus 로고    scopus 로고
    • Corrosion study of copper/LDPE nanocomposits in simulated uterine solution
    • Cai S, Xia X, Xie C Corrosion study of copper/LDPE nanocomposits in simulated uterine solution. Biomaterials, 2005, 26: 2671-2676
    • (2005) Biomaterials , vol.26 , pp. 2671-2676
    • Cai, S.1    Xia, X.2    Xie, C.3
  • 4
    • 0032458547 scopus 로고    scopus 로고
    • Can intrauterine device removals for bleeding or pain be predicted at a one-month follow-up visit?
    • Stanback J, Grimes D. Can intrauterine device removals for bleeding or pain be predicted at a one-month follow-up visit? Contraception, 1998, 58: 357-360
    • (1998) Contraception , vol.58 , pp. 357-360
    • Stanback, J.1    Grimes, D.2
  • 5
    • 0034748450 scopus 로고    scopus 로고
    • Determination of an acute observed-adverse-effect level(NOAEL) for copper in water
    • Araya M, Mc Goldrick M C, Klevay L M, et al. Determination of an acute observed-adverse-effect level(NOAEL) for copper in water. Regul Toxicol Pharmacal, 2001, 34: 137-145
    • (2001) Regul Toxicol Pharmacal , vol.34 , pp. 137-145
    • Araya, M.1    Mc Goldrick, M.C.2    Klevay, L.M.3
  • 6
    • 0036263267 scopus 로고    scopus 로고
    • Thermolecular basis of copper homeostasis and copper-related disorders
    • Lianos R M, Mercer J F B. Thermolecular basis of copper homeostasis and copper-related disorders. DNA Cell Biol, 2002, 21: 259-270
    • (2002) DNA Cell Biol , vol.21 , pp. 259-270
    • Lianos, R.M.1    Mercer, J.F.B.2
  • 7
    • 0036525717 scopus 로고    scopus 로고
    • Molecular mechanisms of copper uptake and distribution
    • Puig S, Thiele D. Molecular mechanisms of copper uptake and distribution. Curr Opin Chem Biol, 2002, 6: 171-180
    • (2002) Curr Opin Chem Biol , vol.6 , pp. 171-180
    • Puig, S.1    Thiele, D.2
  • 8
    • 0034283387 scopus 로고    scopus 로고
    • Physiological oxygen tensions modulate expression of the mdrlb multigrug-resistance gene in primary rat heptocyte culture
    • Hirsh-Ernst K I, Kietzmann T, Ziemann C, et al. Physiological oxygen tensions modulate expression of the mdrlb multigrug-resistance gene in primary rat heptocyte culture. Biochemistry, 2000, 350: 443-451
    • (2000) Biochemistry , vol.350 , pp. 443-451
    • Hirsh-Ernst, K.I.1    Kietzmann, T.2    Ziemann, C.3
  • 9
    • 0027235484 scopus 로고
    • Osmolarity and growth phase overlap in regulation of Salmonella typhi adherence to and invasion of human intestinal cells
    • Tertera C, Metcalf E S. Osmolarity and growth phase overlap in regulation of Salmonella typhi adherence to and invasion of human intestinal cells. Infect Immun, 1993, 61: 3084-3089
    • (1993) Infect Immun , vol.61 , pp. 3084-3089
    • Tertera, C.1    Metcalf, E.2
  • 10
    • 0010594670 scopus 로고
    • Preliminary studies on the release of indomethacin from a silastic rubber device and its histo-compatibility (in Chinese)
    • Wang Y, Liu Y, Dong J, et al. Preliminary studies on the release of indomethacin from a silastic rubber device and its histo-compatibility (in Chinese). Reprod Contracept, 1989, 9: 25-27
    • (1989) Reprod Contracept , vol.9 , pp. 25-27
    • Wang, Y.1    Liu, Y.2    Dong, J.3
  • 11
    • 40649088694 scopus 로고    scopus 로고
    • A pharmacodynamic study on indomethacin IUD
    • Liu C, Li S, Liu X, et al. A pharmacodynamic study on indomethacin IUD. Reprod Contracept, 2000, 20: 165-171
    • (2000) Reprod Contracept , vol.20 , pp. 165-171
    • Liu, C.1    Li, S.2    Liu, X.3
  • 12
    • 31944448042 scopus 로고    scopus 로고
    • A comparative study of y Cu380 IUD and TCu 380A IUD
    • Yang X, Zhang L, Xu M, et al. A comparative study of y Cu380 IUD and TCu 380A IUD. Reprod Contracep, 2000, 20: 26-29
    • (2000) Reprod Contracep , vol.20 , pp. 26-29
    • Yang, X.1    Zhang, L.2    Xu, M.3
  • 13
    • 40649117023 scopus 로고    scopus 로고
    • Corrosion study of copper bearing intrauterine devices (Cu-IUD)
    • Cai S, Xia X, Xie C Corrosion study of copper bearing intrauterine devices (Cu-IUD). Reprod Contracep, 2004, 24: 299-302
    • (2004) Reprod Contracep , vol.24 , pp. 299-302
    • Cai, S.1    Xia, X.2    Xie, C.3
  • 14
    • 84858339425 scopus 로고    scopus 로고
    • Investigation of release behavior of cupric ion for three types of Cu-IUDs and indomethacin for medicated Cu-IUD in vitro
    • Liang J, Li Y. Investigation of release behavior of cupric ion for three types of Cu-IUDs and indomethacin for medicated Cu-IUD in vitro. Reprod Contracep, 2008, 28: 22-24
    • (2008) Reprod Contracep , vol.28 , pp. 22-24
    • Liang, J.1    Li, Y.2
  • 15
    • 0031946292 scopus 로고    scopus 로고
    • Corrosion behavior of copper in a copper bearing intrauterine device in the presence of indomethacin
    • Xue H, Xu N, Zhang C. Corrosion behavior of copper in a copper bearing intrauterine device in the presence of indomethacin. Contraception, 1998, 57: 49-53
    • (1998) Contraception , vol.57 , pp. 49-53
    • Xue, H.1    Xu, N.2    Zhang, C.3
  • 16
    • 0033843191 scopus 로고    scopus 로고
    • Copper corrosion-simulated uterine solutions
    • Bastidas J M, Mora N, Cano E. Copper corrosion-simulated uterine solutions. Contraception, 2000, 61: 395-399
    • (2000) Contraception , vol.61 , pp. 395-399
    • Bastidas, J.M.1    Mora, N.2    Cano, E.3
  • 17
    • 0036132475 scopus 로고    scopus 로고
    • Influence of pH and oxygen on copper corrosion in simulated uterine fluid
    • Mora N, Cano E, Mora E M, et al. Influence of pH and oxygen on copper corrosion in simulated uterine fluid. Biomaterials, 2002, 23: 667-671
    • (2002) Biomaterials , vol.23 , pp. 667-671
    • Mora, N.1    Cano, E.2    Mora, E.M.3
  • 18
    • 11344257292 scopus 로고    scopus 로고
    • Molecular spectroscopic study on the interaction of tetracyclines with serum albumins
    • Bi S Y, Song D Q, Ding L, et al. Molecular spectroscopic study on the interaction of tetracyclines with serum albumins. Spectrochim Acta Part A, 2005, 61: 629-636
    • (2005) Spectrochim Acta Part A , vol.61 , pp. 629-636
    • Bi, S.Y.1    Song, D.Q.2    Ding, L.3
  • 19
    • 40649087715 scopus 로고    scopus 로고
    • Study on indomethacin release in vitro of active yuangong type 365 drug-releasing copper-bearing intrauterine contraceptive device
    • Gao J, Li Y. Study on indomethacin release in vitro of active yuangong type 365 drug-releasing copper-bearing intrauterine contraceptive device. Reprod Contracept, 2006, 26: 602-606
    • (2006) Reprod Contracept , vol.26 , pp. 602-606
    • Gao, J.1    Li, Y.2
  • 20
    • 72649091542 scopus 로고    scopus 로고
    • Release behavior of cupric ion for TCu380A IUD and TCu220C IUD
    • Cao B, Xi T, Zheng Y. Release behavior of cupric ion for TCu380A IUD and TCu220C IUD. Biomed Mater, 2008, 3: 1-7
    • (2008) Biomed Mater , vol.3 , pp. 1-7
    • Cao, B.1    Xi, T.2    Zheng, Y.3
  • 21
    • 0030111585 scopus 로고    scopus 로고
    • The corrosion behavior of copper in simulated uterine fluid
    • Zhang C, Xu N, Yang B. The corrosion behavior of copper in simulated uterine fluid. Corros Sci, 1996, 38: 635-641
    • (1996) Corros Sci , vol.38 , pp. 635-641
    • Zhang, C.1    Xu, N.2    Yang, B.3
  • 22
    • 0031696892 scopus 로고    scopus 로고
    • Effect of indomethacin on galvanic corrosion of copper and stainless steel on intrauterine device
    • Xue H, Xu N. Effect of indomethacin on galvanic corrosion of copper and stainless steel on intrauterine device. J Chin Soc Corr Prot, 1998, 18: 81-86
    • (1998) J Chin Soc Corr Prot , vol.18 , pp. 81-86
    • Xue, H.1    Xu, N.2
  • 23
    • 0015023182 scopus 로고
    • Contraception through the use of intrauterine "T" device. The endouterine copper "T"
    • Zipper J, Tatum H, Medel M, et al. Contraception through the use of intrauterine "T" device. The endouterine copper "T". Am J Obstet Gynecol, 1971, 109: 771-774
    • (1971) Am J Obstet Gynecol , vol.109 , pp. 771-774
    • Zipper, J.1    Tatum, H.2    Medel, M.3
  • 24
    • 38749086441 scopus 로고    scopus 로고
    • Should the galvanic combination of titanium and stainless steel surgical implants be avoided?
    • Paul J H, Anders M, Nils R G. Should the galvanic combination of titanium and stainless steel surgical implants be avoided? Injury Int J Care Injured, 2008, 39: 161-169
    • (2008) Injury Int J Care Injured , vol.39 , pp. 161-169
    • Paul, J.H.1    Anders, M.2    Nils, R.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.