메뉴 건너뛰기




Volumn 44, Issue , 2012, Pages 141-153

Interactions between the physical soil environment and a horizontal ground coupled heat pump, for a domestic site in the UK

Author keywords

Coefficient of Performance; Heat extraction; Horizontal ground source heat pumps; Renewable energy; Soil thermal properties

Indexed keywords

COEFFICIENT OF PERFORMANCE; DEPARTMENT OF ENERGY; EUROPEAN COMMUNITY; GOVERNMENT AGENCIES; GROUND HEAT EXCHANGERS; GROUND-COUPLED HEAT PUMP; HEAT EXTRACTION; HEAT-RESOURCE; HORIZONTAL HEAT EXCHANGER; INTERNATIONAL ENERGY AGENCY; KNOWLEDGE BASE; MECHANISTIC STUDIES; MODEL VERIFICATION; MOISTURE MIGRATION; PHYSICAL ENVIRONMENTS; PHYSICAL RESOURCES; RENEWABLE ENERGIES; SIMULATION MODEL; SOIL ENVIRONMENT; SOIL PROFILES; SOIL TEMPERATURE; SOIL THERMAL PROPERTIES; SURROUNDING SOILS; SUSTAINABLE USE;

EID: 84858295651     PISSN: 09601481     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.renene.2012.01.080     Document Type: Article
Times cited : (59)

References (23)
  • 1
  • 2
    • 71949123375 scopus 로고    scopus 로고
    • Factors influencing the uptake of heat pump technology by the UK domestic sector
    • Singh H., Muetze A., Eames P.C. Factors influencing the uptake of heat pump technology by the UK domestic sector. Renewable Energy 2010, 35(4):873-878.
    • (2010) Renewable Energy , vol.35 , Issue.4 , pp. 873-878
    • Singh, H.1    Muetze, A.2    Eames, P.C.3
  • 3
    • 33751188092 scopus 로고    scopus 로고
    • Numerical and experimental analysis of a horizontal ground-coupled heat pump system
    • Esen H., Inalli M., Esen M. Numerical and experimental analysis of a horizontal ground-coupled heat pump system. Building and Environment Journal 2007, 42:1126-1134.
    • (2007) Building and Environment Journal , vol.42 , pp. 1126-1134
    • Esen, H.1    Inalli, M.2    Esen, M.3
  • 4
    • 33646379601 scopus 로고    scopus 로고
    • Development of a design and performance prediction tool for the ground source heat pump system
    • Nagano K., Katsura T., Takeda S. Development of a design and performance prediction tool for the ground source heat pump system. Applied Thermal Engineering 2006, 26:1578-1592.
    • (2006) Applied Thermal Engineering , vol.26 , pp. 1578-1592
    • Nagano, K.1    Katsura, T.2    Takeda, S.3
  • 7
    • 33846807222 scopus 로고    scopus 로고
    • An improved model for predicting soil thermal conductivity from water content at room temperature
    • Lu S., Ren T., Gong Y., Horton R. An improved model for predicting soil thermal conductivity from water content at room temperature. Soil Science Society of America Journal 2007, 71:8-14.
    • (2007) Soil Science Society of America Journal , vol.71 , pp. 8-14
    • Lu, S.1    Ren, T.2    Gong, Y.3    Horton, R.4
  • 8
    • 34547910654 scopus 로고    scopus 로고
    • Numerical analysis of coupled water, vapor and heat transport in the vadose zone
    • Saito H., Simunek J., Mohanty B. Numerical analysis of coupled water, vapor and heat transport in the vadose zone. Vadose Zone Journal 2006, 5:784-800.
    • (2006) Vadose Zone Journal , vol.5 , pp. 784-800
    • Saito, H.1    Simunek, J.2    Mohanty, B.3
  • 9
    • 0032294614 scopus 로고    scopus 로고
    • Effect of soil type and moisture content on ground heat pump performance
    • Leong W., Tarnawski V., Aittomaki A. Effect of soil type and moisture content on ground heat pump performance. International Journal of Refrigeration 1998, 21(8):595-606.
    • (1998) International Journal of Refrigeration , vol.21 , Issue.8 , pp. 595-606
    • Leong, W.1    Tarnawski, V.2    Aittomaki, A.3
  • 10
    • 0027643368 scopus 로고
    • Computer analysis, design and simulation of horizontal ground heat exchangers
    • Tarnawski V.R., Leong W.H. Computer analysis, design and simulation of horizontal ground heat exchangers. International Journal of Energy Research 1993, 17:467-477.
    • (1993) International Journal of Energy Research , vol.17 , pp. 467-477
    • Tarnawski, V.R.1    Leong, W.H.2
  • 11
    • 84858071386 scopus 로고    scopus 로고
    • Publication date: 08/09/2010, The Energy Saving Trust (EST)
    • The Energy Saving Trust (EST) Getting warmer: a field trial of heat pumps 2010, Publication date: 08/09/2010. http://www.energysavingtrust.org.uk/Media/node_1422/Getting-warmer-a-field-trial-of-heat-pumps-PDF.
    • (2010) Getting warmer: a field trial of heat pumps
  • 12
    • 77956230251 scopus 로고    scopus 로고
    • Experimental measurement and numerical simulation of horizontal-coupled slinky ground source heat exchangers
    • Wu Y., Gan G., Verhoef A., Vidale P.L., Garcia Gonzalez R. Experimental measurement and numerical simulation of horizontal-coupled slinky ground source heat exchangers. Applied Thermal Engineering 2010, 30(16):2574-2583.
    • (2010) Applied Thermal Engineering , vol.30 , Issue.16 , pp. 2574-2583
    • Wu, Y.1    Gan, G.2    Verhoef, A.3    Vidale, P.L.4    Garcia Gonzalez, R.5
  • 13
    • 19144365508 scopus 로고    scopus 로고
    • Comments on "Estimating soil water contents from soil temperature measurements by using an Adaptive Kalman Filter"
    • Yang K., Koike T. Comments on "Estimating soil water contents from soil temperature measurements by using an Adaptive Kalman Filter". Journal of Applied Meteorology 2005, 44:546-550.
    • (2005) Journal of Applied Meteorology , vol.44 , pp. 546-550
    • Yang, K.1    Koike, T.2
  • 14
    • 84862799240 scopus 로고
    • Thermal conductivity of soils. PhD thesis, University of Trondhei
    • Johansen O. Thermal conductivity of soils. PhD thesis, University of Trondheim 1975, p. 236.
    • (1975) , pp. 236
    • Johansen, O.1
  • 16
    • 18644371546 scopus 로고    scopus 로고
    • Development of thermo-time domain reflectometry for vadose zone measurements
    • Ren T., Ochsner T.E., Horton R. Development of thermo-time domain reflectometry for vadose zone measurements. Vadose Zone Journal 2003, 2:544-551.
    • (2003) Vadose Zone Journal , vol.2 , pp. 544-551
    • Ren, T.1    Ochsner, T.E.2    Horton, R.3
  • 17
    • 0042395029 scopus 로고
    • Soil moisture transport due to thermal gradients: practical aspects
    • Cary J.W. Soil moisture transport due to thermal gradients: practical aspects. Soil Science Society of America Proceedings 1966, 30(4):428-433.
    • (1966) Soil Science Society of America Proceedings , vol.30 , Issue.4 , pp. 428-433
    • Cary, J.W.1
  • 18
    • 0344348982 scopus 로고    scopus 로고
    • Experimental analysis of unsteady heat and moisture transfer around a heated cylinder buried into a porous medium
    • Moya R.E.S., Prata A.T., Cunha Neto J.A.B. Experimental analysis of unsteady heat and moisture transfer around a heated cylinder buried into a porous medium. International Journal of Heat and Mass Transfer 1999, 42:2187-2198.
    • (1999) International Journal of Heat and Mass Transfer , vol.42 , pp. 2187-2198
    • Moya, R.E.S.1    Prata, A.T.2    Cunha Neto, J.A.B.3
  • 19
    • 0019938255 scopus 로고
    • Moisture and heat transport in hysteretic inhomogeneous porous media: a matric head- based formulation and a numerical model
    • Milly P.C.D. Moisture and heat transport in hysteretic inhomogeneous porous media: a matric head- based formulation and a numerical model. Water Resource. Research 1982, 18:489-498.
    • (1982) Water Resource. Research , vol.18 , pp. 489-498
    • Milly, P.C.D.1
  • 21
    • 78650753054 scopus 로고    scopus 로고
    • Global warming's impact on the performance of GSHP
    • Kharseh M., Altorkmany L., Nordell B. Global warming's impact on the performance of GSHP. Renewable Energy 2011, 36(5):1485-1491.
    • (2011) Renewable Energy , vol.36 , Issue.5 , pp. 1485-1491
    • Kharseh, M.1    Altorkmany, L.2    Nordell, B.3
  • 22
    • 51649103727 scopus 로고    scopus 로고
    • Analysis of ground source heat pumps with horizontal ground heat exchangers for northern Japan
    • Tarnawski V.R., Leong W.H., Momose T., Hamada Y. Analysis of ground source heat pumps with horizontal ground heat exchangers for northern Japan. Renewable Energy 2009, 34(1):127-134.
    • (2009) Renewable Energy , vol.34 , Issue.1 , pp. 127-134
    • Tarnawski, V.R.1    Leong, W.H.2    Momose, T.3    Hamada, Y.4
  • 23
    • 33847122614 scopus 로고    scopus 로고
    • Performance assessment of a horizontal-coil geothermal heat pump
    • Yari M., Javani N. Performance assessment of a horizontal-coil geothermal heat pump. International Journal of Energy Research 2007, 31:288-299.
    • (2007) International Journal of Energy Research , vol.31 , pp. 288-299
    • Yari, M.1    Javani, N.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.