메뉴 건너뛰기




Volumn 81, Issue 4, 2012, Pages

Low voltage CTPA for patients with suspected pulmonary embolism

Author keywords

Computed tomography; Pulmonary embolism; Technique

Indexed keywords

CONTRAST MEDIUM;

EID: 84858292276     PISSN: 0720048X     EISSN: 18727727     Source Type: Journal    
DOI: 10.1016/j.ejrad.2011.06.051     Document Type: Article
Times cited : (24)

References (6)
  • 2
    • 35348977748 scopus 로고    scopus 로고
    • Image quality and radiation exposure at pulmonary CT angiography with 100- or 120-kVp protocol: Prospective randomized study
    • DOI 10.1148/radiol.2452061919
    • C.M. Heyer, P.S. Mohr, S.P. Lemburg, S.A. Peters, and V. Nicolas Image quality and radiation exposure at pulmonary CT angiography with 100- or 120-kVp protocol: prospective randomized study Radiology 245 2 2007 577 583 (Pubitemid 47612541)
    • (2007) Radiology , vol.245 , Issue.2 , pp. 577-583
    • Heyer, C.M.1    Mohr, P.S.2    Lemburg, S.P.3    Peters, S.A.4    Nicolas, V.5
  • 3
    • 33846695725 scopus 로고    scopus 로고
    • CT angiography of pulmonary arteries to detect pulmonary embolism: Improvement of vascular enhancement with low kilovoltage settings
    • DOI 10.1148/radiol.2413040128
    • C. Schueller-Weidekamm, C.M. Schaefer-Prokop, M. Weber, C.J. Herold, and M. Prokop CT angiography of pulmonary arteries to detect pulmonary embolism: improvement of vascular enhancement with low kilovoltage settings Radiology 241 3 2006 899 907 (Pubitemid 46190558)
    • (2006) Radiology , vol.241 , Issue.3 , pp. 899-907
    • Schueller-Weidekamm, C.1    Schaefer-Prokop, C.M.2    Weber, M.3    Herold, C.J.4    Prokop, M.5
  • 4
    • 40949104442 scopus 로고    scopus 로고
    • The 2007 Recommendations of the International Commission on Radiological Protection
    • ICRP Publication 103
    • The 2007 Recommendations of the International Commission on Radiological Protection. ICRP Publication 103. Ann ICRP 2007;37(2-4):1-332.
    • (2007) Ann ICRP , vol.37 , Issue.2-4 , pp. 1-332
  • 5
    • 0033730930 scopus 로고    scopus 로고
    • Using 80 kVp versus 120 kVp in perfusion CT measurement of regional cerebral blood flow
    • M. Wintermark, P. Maeder, and F.R. Verdun Using 80 kVp versus 120 kVp in perfusion CT measurement of regional cerebral blood flow AJNR Am J Neuroradiol 21 10 2000 1881 1884
    • (2000) AJNR Am J Neuroradiol , vol.21 , Issue.10 , pp. 1881-1884
    • Wintermark, M.1    Maeder, P.2    Verdun, F.R.3
  • 6
    • 1642389455 scopus 로고    scopus 로고
    • Low-Kilovoltage Multi-Detector Row Chest CT in Adults: Feasibility and Effect on Image Quality and Iodine Dose
    • DOI 10.1148/radiol.2311030191
    • A.B. Sigal-Cinqualbre, R. Hennequin, H.T. Abada, X. Chen, and J.F. Paul Low-kilovoltage multi-detector row chest CT in adults: feasibility and effect on image quality and iodine dose Radiology 231 1 2004 169 174 (Pubitemid 38375425)
    • (2004) Radiology , vol.231 , Issue.1 , pp. 169-174
    • Sigal-Cinqualbre, A.B.1    Hennequin, R.2    Abada, H.T.3    Chen, X.4    Paul, J.-F.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.