메뉴 건너뛰기




Volumn 15, Issue , 2007, Pages 427-430

Reduction of movement artifacts in photoplethysmograph using SFLC (Scaled fourier linear combiner)

Author keywords

Fourier linear combiner; Motion artifacts; Noise canceller; Photoplethysmograph

Indexed keywords

BIOMEDICAL ENGINEERING; FOURIER TRANSFORMS; HEALTH CARE; HEART; MEDICAL COMPUTING;

EID: 84858153024     PISSN: 16800737     EISSN: 14339277     Source Type: Conference Proceeding    
DOI: 10.1007/978-3-540-68017-8_108     Document Type: Conference Paper
Times cited : (2)

References (8)
  • 1
    • 0041863311 scopus 로고    scopus 로고
    • Biomonitoring with wireless communications
    • Budinger, T. F., Biomonitoring with wireless communications. Annu Rev Biomed Eng, 2003. 5: p. 383-412.
    • (2003) Annu Rev Biomed Eng , vol.5 , pp. 383-412
    • Budinger, T.F.1
  • 2
    • 0141610987 scopus 로고    scopus 로고
    • Mobile monitoring with wearable photoplethysmographic biosensors
    • Asada, H. H., et al., Mobile monitoring with wearable photoplethysmographic biosensors. IEEE Eng Med Biol Mag, 2003. 22(3): p. 28-40.
    • (2003) IEEE Eng Med Biol Mag , vol.22 , Issue.3 , pp. 28-40
    • Asada, H.H.1
  • 3
    • 0035073348 scopus 로고    scopus 로고
    • A new method for pulse oximetry possessing inherent insensitivity to artifact
    • Hayes, M. J. and P. R. Smith, A new method for pulse oximetry possessing inherent insensitivity to artifact. IEEE Trans Biomed Eng, 2001. 48(4): p. 452-61.
    • (2001) IEEE Trans Biomed Eng , vol.48 , Issue.4 , pp. 452-461
    • Hayes, M.J.1    Smith, P.R.2
  • 4
    • 0141722628 scopus 로고    scopus 로고
    • Stress Monitoring Using a Distributed Wireless Intelligent Sensor System
    • Jovanov, E., et al., Stress Monitoring Using a Distributed Wireless Intelligent Sensor System, in IEEE Engineering in Medicine and Biology Magazine. 2003. p. 49-55.
    • (2003) IEEE Engineering in Medicine and Biology Magazine , pp. 49-55
    • Jovanov, E.1
  • 6
    • 0029256652 scopus 로고
    • Filtering noncorrelated noise in impedance cardiography
    • Barros, A. K., M. Yoshizawa, and Y. Yasuda, Filtering noncorrelated noise in impedance cardiography. IEEE Trans Biomed Eng, 1995. 42(3): p. 324-7.
    • (1995) IEEE Trans Biomed Eng , vol.42 , Issue.3 , pp. 324-327
    • Barros, A.K.1    Yoshizawa, M.2    Yasuda, Y.3
  • 7
    • 0026933249 scopus 로고
    • Adaptive filter for event-related bioelectric signals using an impulse correlated reference input: Comparison with signal averaging techniques
    • Laguna, P., et al., Adaptive filter for event-related bioelectric signals using an impulse correlated reference input: comparison with signal averaging techniques. IEEE Trans Biomed Eng, 1992. 39(10): p. 1032-44.
    • (1992) IEEE Trans Biomed Eng , vol.39 , Issue.10 , pp. 1032-1044
    • Laguna, P.1
  • 8
    • 0025455994 scopus 로고
    • Accuracy and utility of pulse oximetry in the surgical intensive care unit
    • Bentt, L. R., et al., Accuracy and utility of pulse oximetry in the surgical intensive care unit. Curr Surg, 1990. 47(4): p. 267-8.
    • (1990) Curr Surg , vol.47 , Issue.4 , pp. 267-268
    • Bentt, L.R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.