메뉴 건너뛰기




Volumn 78, Issue 8, 2012, Pages 585-589

Evidence-based guideline update: Intraoperative spinal monitoring with somatosensory and transcranial electrical motor evoked potentials - Report of the therapeutics and technology assessment subcommittee of the american academy of neurology and the american clinical neurophysiology society

(12)  Nuwer, M R a   Emerson, R G b   Galloway, G c   Legatt, A D d   Lopez, J e   Minahan, R f   Yamada, T g   Goodin, D S h   Armon, C i   Chaudhry, V j   Gronseth, G S k   Harden, C L l  


Author keywords

[No Author keywords available]

Indexed keywords

ADVERSE OUTCOME; EVIDENCE BASED PRACTICE; EVOKED MUSCLE RESPONSE; EVOKED SOMATOSENSORY RESPONSE; HUMAN; MEDICAL RECORD REVIEW; PARAPLEGIA; PATIENT MONITORING; PRACTICE GUIDELINE; PRIORITY JOURNAL; QUADRIPLEGIA; REVIEW; SPINE SURGERY; TREATMENT OUTCOME;

EID: 84858145427     PISSN: 00283878     EISSN: 1526632X     Source Type: Journal    
DOI: 10.1212/WNL.0b013e318247fa0e     Document Type: Article
Times cited : (118)

References (26)
  • 1
    • 37349083869 scopus 로고    scopus 로고
    • Intraoperative Monitoring of Neural Function
    • Amsterdam: Elsevier; Daube JR, Marguiére F, series eds.
    • Nuwer MR, ed. Intraoperative Monitoring of Neural Function. Amsterdam: Elsevier; 2008. Daube JR, Marguiére F, series eds. Handbook of Clinical Neurophysiology; vol 8.
    • (2008) Handbook of Clinical Neurophysiology , vol.8
    • Nuwer, M.R.1
  • 2
    • 0028881660 scopus 로고
    • Somatosensory evoked potential spinal cord monitoring reduces neurologic deficits after scoliosis surgery: Results of a large multicenter survey
    • Nuwer MR, Dawson EG, Carlson G, Kanim LEA, Sherman JE. Somatosensory evoked potential spinal cord monitoring reduces neurologic deficits after scoliosis surgery: results of a large multicenter survey. Electroencephalogr Clin Neurophysiol 1995;96:6-11.
    • (1995) Electroencephalogr Clin Neurophysiol , vol.96 , pp. 6-11
    • Nuwer, M.R.1    Dawson, E.G.2    Carlson, G.3    Kanim, L.E.A.4    Sherman, J.E.5
  • 3
    • 33745085168 scopus 로고    scopus 로고
    • Motor evoked potential monitoring improves outcome after surgery for intramedullary spinal cord tumors: A historical control study
    • Sala F, Palandri G, Basso E, et al. Motor evoked potential monitoring improves outcome after surgery for intramedullary spinal cord tumors: a historical control study. Neurosurgery 2006;58:1129-1143.
    • (2006) Neurosurgery , vol.58 , pp. 1129-1143
    • Sala, F.1    Palandri, G.2    Basso, E.3
  • 4
    • 0023099839 scopus 로고
    • Improved preservation of facial nerve function with use of electrical monitoring during removal of acoustic neuromas
    • Harner SG, Daube JR, Ebersold MJ, Beatty CW. Improved preservation of facial nerve function with use of electrical monitoring during removal of acoustic neuromas. Mayo Clin Proc 1987;62:92-102. (Pubitemid 17016449)
    • (1987) Mayo Clinic Proceedings , vol.62 , Issue.2 , pp. 92-102
    • Harner, S.G.1    Daube, J.R.2    Ebersold, M.J.3    Beatty, C.W.4
  • 5
    • 0024535590 scopus 로고
    • Intraoperative brainstem auditory evoked potentials: Significant decrease in postoperative morbidity
    • Radtke RA, Erwin CW, Wilkins RH. Intraoperative brain-stem auditory evoked potentials: significant decrease in postoperative morbidity. Neurology 1989;39:187-191. (Pubitemid 19059301)
    • (1989) Neurology , vol.39 , Issue.2 I , pp. 187-191
    • Radtke, R.A.1    Erwin, C.W.2    Wilkins, R.H.3
  • 6
    • 77951765823 scopus 로고    scopus 로고
    • The evidence for intraoperative neurophysiological monitoring in spine surgery: Does it make a difference?
    • Fehlings MG, Brodke DS, Norvell DC, Dettori JR. The evidence for intraoperative neurophysiological monitoring in spine surgery: does it make a difference? Spine 2010;35: S37-S46.
    • (2010) Spine , vol.35
    • Fehlings, M.G.1    Brodke, D.S.2    Norvell, D.C.3    Dettori, J.R.4
  • 7
    • 0023394116 scopus 로고
    • Monitoring of somatosensory evoked potentials during surgical procedures on the thoracoabdominal aorta: IV: clinical observations and results
    • Cunningham JN Jr, Laschinger JC, Spencer FC. Monitoring of somatosensory evoked potentials during surgical procedures on the thoracoabdominal aorta: IV: clinical observations and results. J Thorac Cardiovasc Surg 94:275-285, 1987.
    • (1987) J Thorac Cardiovasc Surg , vol.94 , pp. 275-285
    • Cunningham Jr., J.N.1    Laschinger, J.C.2    Spencer, F.C.3
  • 8
    • 35649019221 scopus 로고    scopus 로고
    • The validity of multimodal intraoperative monitoring (MIOM) in surgery of 109 spine and spinal cord tumors
    • DOI 10.1007/s00586-007-0422-y, Multimodal Intraoperative Monitoring in Spine Surgery
    • Sutter M, Eggspuehler A, Grob D, et al. The validity of multimodal intraoperative monitoring (MIOM) in surgery of 109 spine and spinal cord tumors. Eur Spine J 2007;16: S197-S208. (Pubitemid 350029516)
    • (2007) European Spine Journal , vol.16 , Issue.SUPPL. 2
    • Sutter, M.1    Eggspuehler, A.2    Grob, D.3    Jeszenszky, D.4    Benini, A.5    Porchet, F.6    Mueller, A.7    Dvorak, J.8
  • 10
    • 33847769923 scopus 로고    scopus 로고
    • Combined motor and somatosensory evoked potentials for intraoperative monitoring: Intra- and postoperative data in a series of 69 operations
    • DOI 10.1007/s10143-006-0061-5
    • Weinzierl MR, Reinacher P, Gilsbach JM, Rohde V. Combined motor and somatosensory evoked potentials for intraoperative monitoring: intra- and postoperative data in a series of 69 operations. Neurosurg Rev 2007;30:109-116. (Pubitemid 46393012)
    • (2007) Neurosurgical Review , vol.30 , Issue.2 , pp. 109-116
    • Weinzierl, M.R.1    Reinacher, P.2    Gilsbach, J.M.3    Rohde, V.4
  • 11
    • 33750053284 scopus 로고    scopus 로고
    • Thoracic and thoracoabdominal aneurysm repair: Is reimplantation of spinal cord arteries a waste of time?
    • Etz CD, Halstead JC, Spielvogel D, et al. Thoracic and thoracoabdominal aneurysm repair: is reimplantation of spinal cord arteries a waste of time? Ann Thorac Surg 2006;82:1670-1678.
    • (2006) Ann Thorac Surg , vol.82 , pp. 1670-1678
    • Etz, C.D.1    Halstead, J.C.2    Spielvogel, D.3
  • 12
    • 0029841262 scopus 로고    scopus 로고
    • Somatosensory evoked potential monitoring in cervical surgery: Identification of pre- and intraoperative risk factors associated with neurological deterioration
    • May DM, Jones SJ, Crockard HA. Somatosensory evoked potential monitoring in cervical surgery: Identification of pre- and post-operative risk factors associated with neurological deterioration. J Neurosurg 1996;85:566-573. (Pubitemid 26315187)
    • (1996) Journal of Neurosurgery , vol.85 , Issue.4 , pp. 566-573
    • May, D.M.1    Jones, S.J.2    Crockard, H.A.3
  • 14
    • 0036090007 scopus 로고    scopus 로고
    • Combined monitoring of motor and somatosensory evoked potentials in orthopaedic spinal surgery
    • DOI 10.1016/S1388-2457(02)00027-5, PII S1388245702000275
    • Pelosi L, Lamb J, Grevitt M, Mehdian SMH, Webb JK, Blumhardt LD. Combined monitoring of motor and somatosensory evoked potentials in orthopaedic spinal surgery. Clin Neurophysiol 2002;113:1082-1091. (Pubitemid 34667147)
    • (2002) Clinical Neurophysiology , vol.113 , Issue.7 , pp. 1082-1091
    • Pelosi, L.1    Lamb, J.2    Grevitt, M.3    Mehdian, S.M.H.4    Webb, J.K.5    Blumhardt, L.D.6
  • 17
    • 0037648812 scopus 로고    scopus 로고
    • Transcranial electrical motor-evoked potential monitoring during surgery for spinal deformity: A study of 145 patients
    • DOI 10.1097/00007632-200305150-00017
    • Langeloo DD, Lelivelt A, Journee L, Slappendel R, de Kleuver M. Transcranial electrical motor-evoked potential monitoring during surgery for spinal deformity: a study of 145 patients. Spine 2003;28:1043-1050. (Pubitemid 36583338)
    • (2003) Spine , vol.28 , Issue.10 , pp. 1043-1050
    • Langeloo, D.D.1    Lelivelt, A.2    Journee, H.L.3    Slappendel, R.4    De Kleuver, M.5
  • 18
  • 19
    • 0019980349 scopus 로고
    • Intraoperative detection of spinal cord ischemia using somatosensory cortical evoked potentials during thoracic aortic occlusion
    • Coles JG, Wilson GJ, Sima AF, Klement P, Tait GA. Intraoperative detection of spinal cord ischemia using somatosensory cortical evoked potentials during thoracic aortic occlusion. Ann Thorac Surg 1982;34:299-306. (Pubitemid 12061871)
    • (1982) Annals of Thoracic Surgery , vol.34 , Issue.3 , pp. 299-306
    • Coles, J.G.1    Wilson, G.J.2    Sima, A.F.3
  • 20
    • 0018566139 scopus 로고
    • Evoked spinal potentials as a monitor of spinal cord viability
    • Kojima Y, Yamamoto T, Ogino H, Okada K, Ono K. Evoked spinal potentials as a monitor of spinal cord viability. Spine 1979;4:471-477. (Pubitemid 10190438)
    • (1979) Spine , vol.4 , Issue.6 , pp. 471-477
    • Kojima, Y.1    Yamamoto, T.2    Ogino, H.3
  • 21
    • 0020306666 scopus 로고
    • Detection and prevention of intraoperative spinal cord ischemia after cross-clamping of the thoracic aorta: Use of somatosensory evoked potentials
    • Laschinger JC, Cunningham JN Jr, Catinella FP, Nathan IM, Knopp EA, Spencer FC. Detection and prevention of intraoperative spinal cord ischemia after cross-clamping of the thoracic aorta: use of somatosensory evoked potentials. Surgery 1982;92:1109-1117. (Pubitemid 13083933)
    • (1982) Surgery , vol.92 , Issue.6 , pp. 1109-1117
    • Laschinger, J.C.1    Cunningham Jr., J.N.2    Catinella, F.P.3
  • 22
    • 0021329865 scopus 로고
    • Neurological outcome correlated with spinal evoked potentials in a spinal cord ischemia model
    • Cheng MK, Robertson C, Grossman RG, Foltz R, Williams V. Neurological outcome correlated with spinal evoked potentials in a spinal cord ischemia model. J Neurosurg 1984;60:786-795. (Pubitemid 14165112)
    • (1984) Journal of Neurosurgery , vol.60 , Issue.4 , pp. 786-795
    • Cheng, M.-K.1    Robertson, C.2    Grossman, R.G.3
  • 23
    • 0018567161 scopus 로고
    • Spinal cord monitoring using evoked potentials recorded from feline vertebral bone
    • Nordwall A, Axelgaard J, Harada Y, Valencia P, McNeal DR, Brown JC. Spinal cord monitoring using evoked potentials recorded from feline vertebral bone. Spine 1979;4: 486-494. (Pubitemid 10190440)
    • (1979) Spine , vol.4 , Issue.6 , pp. 486-494
    • Nordwall, A.1    Axelgaard, J.2    Harada, Y.3
  • 24
    • 0020530543 scopus 로고
    • Effects of compression and ischemia on spinal cord evoked potentials
    • Bennett MH. Effects of compression and ischemia on spinal cord evoked potentials. Exp Neurol 1983;80:508-519. (Pubitemid 13074929)
    • (1983) Experimental Neurology , vol.80 , Issue.3 , pp. 508-519
    • Bennett, M.H.1
  • 26
    • 84858145138 scopus 로고    scopus 로고
    • Policy H-410.957. Adopted June Accessed February 1, 2010
    • American Medical Association. Intraoperative neurophysiologic monitoring. Policy H-410.957. Adopted June 2008. https://ssl3.ama-assn.org/apps/ecomm/ PolicyFinder Form.pl?site=www.ama-assn.org&uri=%2fresources% 2fdoc%2fPolicyFinder%2fpolicyfiles%2fHnE%2fH-410. 957.HTM. Accessed February 1, 2010.
    • (2008) Intraoperative Neurophysiologic Monitoring


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.