메뉴 건너뛰기




Volumn 35, Issue 3, 2012, Pages

Electromagnetic device-device interaction between a new generation implantable pacemaker and left ventricular assist device: Recognition and potential solutions

Author keywords

device device interaction; electromagnetic interference; left ventricular assist device; pacemaker

Indexed keywords

AGED; CARDIOMYOPATHY; CASE REPORT; COMMUNICATION SOFTWARE; DEVICE REMOVAL; ELECTROMAGNETIC FIELD; ELECTROMAGNETIC INTERACTION; FLOW RATE; HEART FAILURE; HUMAN; LEFT VENTRICULAR ASSIST DEVICE; MAGNETISM; MALE; PACEMAKER; REVIEW;

EID: 84857978375     PISSN: 01478389     EISSN: 15408159     Source Type: Journal    
DOI: 10.1111/j.1540-8159.2010.02854.x     Document Type: Review
Times cited : (9)

References (13)
  • 1
    • 28744446343 scopus 로고    scopus 로고
    • ACC/AHA 2005 guidelines update for the diagnosis and management of chronic heart failure in the adult: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines
    • Hunt SA, Abraham WT, Chin MH, Feldman AM, Francis GS, Ganiats TG, Jessup M, et al,. ACC/AHA 2005 guidelines update for the diagnosis and management of chronic heart failure in the adult: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines. Circulation 2005; 112: e154-e235.
    • (2005) Circulation , vol.112
    • Hunt, S.A.1    Abraham, W.T.2    Chin, M.H.3    Feldman, A.M.4    Francis, G.S.5    Ganiats, T.G.6    Jessup, M.7
  • 4
    • 2442479695 scopus 로고    scopus 로고
    • Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure
    • Bristow MR, Saxon LA, Boehmer J, Krueger S, Kass DA, De Marco T, Carson P, et al,. Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure. N Engl J Med 2004; 350: 2140-2150.
    • (2004) N Engl J Med , vol.350 , pp. 2140-2150
    • Bristow, M.R.1    Saxon, L.A.2    Boehmer, J.3    Krueger, S.4    Kass, D.A.5    De Marco, T.6    Carson, P.7
  • 6
    • 34547759704 scopus 로고    scopus 로고
    • Chronic Mechanical Circulatory Support for Inotrope-Dependent Heart Failure Patients Who Are Not Transplant Candidates. Results of the INTrEPID Trial
    • DOI 10.1016/j.jacc.2007.03.063, PII S0735109707017767
    • Rogers JG, Butler J, Lansman SL, Gass A, Portner PM, Pasque MK, Pierson RN, et al,. Chronic mechanical circulatory support for inotrope-dependent heart failure patients who are not transplant candidates: Results of the INTrEPID Trial. J Am Coll Cardiol 2007; 50: 741-747. (Pubitemid 47239315)
    • (2007) Journal of the American College of Cardiology , vol.50 , Issue.8 , pp. 741-747
    • Rogers, J.G.1    Butler, J.2    Lansman, S.L.3    Gass, A.4    Portner, P.M.5    Pasque, M.K.6    Pierson III, R.N.7
  • 8
    • 34548702421 scopus 로고    scopus 로고
    • Adverse interaction between a left ventricular assist device and an implantable cardioverter defibrillator
    • DOI 10.1111/j.1540-8167.2007.00805.x
    • Matthews JC, Betley D, Morady F, Pelosi F,. Adverse interaction between a left ventricular assist device and an implantable cardioverter defibrillator. J Cardiovasc Electrophysiol 2007; 18: 1107-1108. (Pubitemid 47416558)
    • (2007) Journal of Cardiovascular Electrophysiology , vol.18 , Issue.10 , pp. 1107-1108
    • Matthews, J.C.1    Betley, D.2    Morady, F.3    Pelosi Jr., F.4
  • 12
    • 78049442006 scopus 로고    scopus 로고
    • "Pseudo" Faraday cage: A solution for telemetry link interaction between a left ventricular assist device and an implantable cardioverter defibrillator
    • (in press)
    • Jacob S, Cherian PK, Ghumman WS, Das MK,. "Pseudo" Faraday cage: A solution for telemetry link interaction between a left ventricular assist device and an implantable cardioverter defibrillator." J Interv Card Electrophysiol 2009 (in press).
    • (2009) J Interv Card Electrophysiol
    • Jacob, S.1    Cherian, P.K.2    Ghumman, W.S.3    Das, M.K.4
  • 13
    • 67650678388 scopus 로고    scopus 로고
    • Overcoming electromagnetic interference by LVADs on ICD function by shielding the ICD programmer wand and extension cable
    • Biviano A, Mancini D, Naka Y, Arellano J, Garan H,. Overcoming electromagnetic interference by LVADs on ICD function by shielding the ICD programmer wand and extension cable. Pacing Clin Electrophysiol 2009; 32: 959-962.
    • (2009) Pacing Clin Electrophysiol , vol.32 , pp. 959-962
    • Biviano, A.1    Mancini, D.2    Naka, Y.3    Arellano, J.4    Garan, H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.