메뉴 건너뛰기




Volumn 18, Issue 2, 2012, Pages 104-108

Validation of the 3-lead tele-ECG versus the 12-lead tele-ECG and the conventional 12-lead ECG method in older people

Author keywords

[No Author keywords available]

Indexed keywords

AGED; ARTICLE; CARDIOLOGY; ELECTROCARDIOGRAPHY; FEMALE; HEART DISEASE; HUMAN; INSTRUMENTATION; MALE; METHODOLOGY; MIDDLE AGED; SELF CARE; STANDARD; TELEMEDICINE; TELEMETRY; VALIDATION STUDY;

EID: 84857880271     PISSN: 1357633X     EISSN: 17581109     Source Type: Journal    
DOI: 10.1258/jtt.2011.110613     Document Type: Article
Times cited : (14)

References (21)
  • 1
    • 58149124087 scopus 로고    scopus 로고
    • Impact of telemonitoring at home on the management of elderly patients with congestive heart failure
    • Antonicelli R, Testarmata P, Spazzafumo L, et al. Impact of telemonitoring at home on the management of elderly patients with congestive heart failure. J Telemed Telecare 2008;14:300-5
    • (2008) J Telemed Telecare , vol.14 , pp. 300-305
    • Antonicelli, R.1    Testarmata, P.2    Spazzafumo, L.3
  • 2
    • 77957727064 scopus 로고    scopus 로고
    • Impact of home patient telemonitoring on use of b-blockers in congestive heart failure
    • Antonicelli R, Mazzanti I, Abbatecola AM, Parati G. Impact of home patient telemonitoring on use of b-blockers in congestive heart failure. Drugs Aging 2010;27:801-5
    • (2010) Drugs Aging , vol.27 , pp. 801-805
    • Antonicelli, R.1    Mazzanti, I.2    Abbatecola, A.M.3    Parati, G.4
  • 3
    • 40049083600 scopus 로고    scopus 로고
    • Outcome parameters for trials in atrial fibrillation: Recommendations from a consensus conference organized by the German Atrial Fibrillation Competence NETwork and the European Heart Rhythm Association
    • Kirchhof P, Auricchio A, Bax J, et al. Outcome parameters for trials in atrial fibrillation: recommendations from a consensus conference organized by the German Atrial Fibrillation Competence NETwork and the European Heart Rhythm Association. Europace 2007;9:1006-23
    • (2007) Europace , vol.9 , pp. 1006-1023
    • Kirchhof, P.1    Auricchio, A.2    Bax, J.3
  • 4
    • 33749168975 scopus 로고    scopus 로고
    • ACC/AHA/ESC 2006 guidelines for the management of patients with atrial fibrillation
    • Fuster V, Rydén LE, Cannom DS, et al. ACC/AHA/ESC 2006 guidelines for the management of patients with atrial fibrillation. Europace 2006;8:651-745
    • (2006) Europace , vol.8 , pp. 651-745
    • Fuster, V.1    Rydén, L.E.2    Cannom, D.S.3
  • 5
    • 77952990457 scopus 로고    scopus 로고
    • Detection of paroxysmal atrial fibrillation with transtelephonic EKG in TIA or stroke patients
    • Gaillard N, Deltour S, Vilotijevic B, et al. Detection of paroxysmal atrial fibrillation with transtelephonic EKG in TIA or stroke patients. Neurology 2010;74:1666-70
    • (2010) Neurology , vol.74 , pp. 1666-1670
    • Gaillard, N.1    Deltour, S.2    Vilotijevic, B.3
  • 6
    • 38649123223 scopus 로고    scopus 로고
    • Guidelines for cardiac pacing and cardiac resynchronization therapy
    • Vardas PE, Auricchio A, Blanc JJ, et al. Guidelines for cardiac pacing and cardiac resynchronization therapy. Europace 2007;9:959-98
    • (2007) Europace , vol.9 , pp. 959-998
    • Vardas, P.E.1    Auricchio, A.2    Blanc, J.J.3
  • 7
    • 0033580207 scopus 로고    scopus 로고
    • Radio-frequency ablation as treatment for cardiac arrhythmias
    • Morady F. Radio-frequency ablation as treatment for cardiac arrhythmias. N Engl J Med 1999;340:534-44
    • (1999) N Engl J Med , vol.340 , pp. 534-544
    • Morady, F.1
  • 8
    • 35748958355 scopus 로고    scopus 로고
    • Validation of 12-lead tele-electrocardiogram transmission in the real-life scenario of acute coronary syndrome
    • Schwaab B, Katalinic A, Richardt G, et al. Validation of 12-lead tele-electrocardiogram transmission in the real-life scenario of acute coronary syndrome. J Telemed Telecare 2006;12:315-8
    • (2006) J Telemed Telecare , vol.12 , pp. 315-318
    • Schwaab, B.1    Katalinic, A.2    Richardt, G.3
  • 9
    • 70349501472 scopus 로고    scopus 로고
    • Prospective, multicentre validation of a simple, patient-operated electrocardiographic system for the detection of arrhythmias and electrocardiographic changes
    • Kaleschke G, Hoffmann B, Drewitz I, et al. Prospective, multicentre validation of a simple, patient-operated electrocardiographic system for the detection of arrhythmias and electrocardiographic changes. Europace 2009;11:1362-8
    • (2009) Europace , vol.11 , pp. 1362-1368
    • Kaleschke, G.1    Hoffmann, B.2    Drewitz, I.3
  • 10
    • 15344344070 scopus 로고    scopus 로고
    • Early outcomes of a care coordination-enhanced telehome care program for elderly veterans with chronic heart failure
    • Schofield RS, Kline SE, Schmalfuss CM, et al. Early outcomes of a care coordination-enhanced telehome care program for elderly veterans with chronic heart failure. Telemed J E Health 2005;11:20-7
    • (2005) Telemed J E Health , vol.11 , pp. 20-27
    • Schofield, R.S.1    Kline, S.E.2    Schmalfuss, C.M.3
  • 11
    • 12244272933 scopus 로고
    • The diagnostic capabilities and limitations of the electrocardiogram
    • In: Hurst J, New York: McGraw Hill
    • Silverman M, Silverman B. The diagnostic capabilities and limitations of the electrocardiogram. In: Hurst J (ed). Update I the Heart. New York: McGraw Hill, 1979
    • (1979) Update I the Heart
    • Silverman, M.1    Silverman, B.2
  • 12
    • 0034861378 scopus 로고    scopus 로고
    • An evidence-based review of the resting electrocardiogram as a screening technique for heart disease
    • Ashley EA, Raxwal V, Froelicher V. An evidence-based review of the resting electrocardiogram as a screening technique for heart disease. Prog Cardiovasc Dis 2001;44:55-67
    • (2001) Prog Cardiovasc Dis , vol.44 , pp. 55-67
    • Ashley, E.A.1    Raxwal, V.2    Froelicher, V.3
  • 15
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-10
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 16
    • 79851511793 scopus 로고    scopus 로고
    • Telecardiology improves quality of diagnosis and reduces delay to treatment in elderly patients with acute myocardial infarction and atypical presentation
    • Brunetti ND, De Gennaro L, Amodio G, et al. Telecardiology improves quality of diagnosis and reduces delay to treatment in elderly patients with acute myocardial infarction and atypical presentation. Eur J Cardiovasc Prev Rehabil 2010;17:615-20
    • (2010) Eur J Cardiovasc Prev Rehabil , vol.17 , pp. 615-620
    • Brunetti, N.D.1    de Gennaro, L.2    Amodio, G.3
  • 17
    • 4043111358 scopus 로고    scopus 로고
    • Suppression of paroxysmal atrial tachyarrhythmias - results of the SOPAT trial
    • Patten M, Maas R, Bauer P, et al. Suppression of paroxysmal atrial tachyarrhythmias - results of the SOPAT trial. Eur Heart J 2004;25:1395-404
    • (2004) Eur Heart J , vol.25 , pp. 1395-1404
    • Patten, M.1    Maas, R.2    Bauer, P.3
  • 18
    • 44749089941 scopus 로고    scopus 로고
    • Prospective comparison of the diagnostic utility of a standard event monitor versus a "leadless" portable ECG monitor in the evaluation of patients with palpitations
    • Scherr D, Dalal D, Henrikson CA, et al. Prospective comparison of the diagnostic utility of a standard event monitor versus a "leadless" portable ECG monitor in the evaluation of patients with palpitations. J Interv Card Electrophysiol 2008;22:39-44
    • (2008) J Interv Card Electrophysiol , vol.22 , pp. 39-44
    • Scherr, D.1    Dalal, D.2    Henrikson, C.A.3
  • 19
    • 26444561511 scopus 로고    scopus 로고
    • Diagnostic yield of patient-activated loop recorders for detecting heart rhythm abnormalities in general practice: A randomised clinical trial
    • Hoefman E, van Weert HC, Reitsma JB, Koster RW, Bindels PJ. Diagnostic yield of patient-activated loop recorders for detecting heart rhythm abnormalities in general practice: a randomised clinical trial. Fam Pract 2005;22:478-84
    • (2005) Fam Pract , vol.22 , pp. 478-484
    • Hoefman, E.1    van Weert, H.C.2    Reitsma, J.B.3    Koster, R.W.4    Bindels, P.J.5
  • 20
    • 0031567881 scopus 로고    scopus 로고
    • Utility and cost of event recorders in the diagnosis of palpitations, presyncope, and syncope
    • Fogel RI, Evans JJ, Prystowsky EN. Utility and cost of event recorders in the diagnosis of palpitations, presyncope, and syncope. Am J Cardiol 1997;79:207-8
    • (1997) Am J Cardiol , vol.79 , pp. 207-208
    • Fogel, R.I.1    Evans, J.J.2    Prystowsky, E.N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.