메뉴 건너뛰기




Volumn 54, Issue , 2012, Pages 116-125

A resistance-capacitance network model for the analysis of the interactions between the energy performance of buildings and the urban climate

Author keywords

Anthropogenic heat; Building energy model; State space; Urban canopy model; Urban heat island

Indexed keywords

ANTHROPOGENIC HEAT; BUILDING ENERGY MODEL; STATE-SPACE; URBAN CANOPY MODELS; URBAN HEAT ISLAND;

EID: 84857672633     PISSN: 03601323     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.buildenv.2012.01.023     Document Type: Article
Times cited : (161)

References (20)
  • 1
    • 79958831400 scopus 로고    scopus 로고
    • Mapping urban climate zones and quantifying climate behaviors - an application on Toulouse urban area (France)
    • Houet T., Pigeon G. Mapping urban climate zones and quantifying climate behaviors - an application on Toulouse urban area (France). Environ Pollut 2011, 159:2180-2192.
    • (2011) Environ Pollut , vol.159 , pp. 2180-2192
    • Houet, T.1    Pigeon, G.2
  • 2
    • 33845491697 scopus 로고    scopus 로고
    • Temporal dynamics of the urban heat island of Singapore
    • Chow W.T.L., Roth M. Temporal dynamics of the urban heat island of Singapore. Int J Climatol 2006, 26:2243-2260.
    • (2006) Int J Climatol , vol.26 , pp. 2243-2260
    • Chow, W.T.L.1    Roth, M.2
  • 3
    • 77954283532 scopus 로고    scopus 로고
    • The urban climate: basic and applied aspects
    • Kuttler W. The urban climate: basic and applied aspects. Urban Ecol 2008, 233-248.
    • (2008) Urban Ecol , pp. 233-248
    • Kuttler, W.1
  • 4
    • 78751699654 scopus 로고    scopus 로고
    • A review of methods for estimating anthropogenic heat and moisture emissions in the urban environment
    • Sailor D.J. A review of methods for estimating anthropogenic heat and moisture emissions in the urban environment. Int J Climatol 2010, 10.1002/joc.2106.
    • (2010) Int J Climatol
    • Sailor, D.J.1
  • 5
    • 33847623246 scopus 로고    scopus 로고
    • Simulating the thermal behaviour of a building during summer period in the urban environment
    • Assimakopoulosa M.N., Mihalakakoub G., Flocas H.A. Simulating the thermal behaviour of a building during summer period in the urban environment. Renew Energy 2007, 32:1805-1816.
    • (2007) Renew Energy , vol.32 , pp. 1805-1816
    • Assimakopoulosa, M.N.1    Mihalakakoub, G.2    Flocas, H.A.3
  • 7
    • 0001834048 scopus 로고
    • Prediction of air temperature variations using the analytical CTTC model
    • Swaid H., Hoffman M.E. Prediction of air temperature variations using the analytical CTTC model. Energy and Build 1990, 14:313-324.
    • (1990) Energy and Build , vol.14 , pp. 313-324
    • Swaid, H.1    Hoffman, M.E.2
  • 8
    • 0024188824 scopus 로고
    • The urban energy balance
    • Oke T.R. The urban energy balance. Prog Phys Geogr 1988, 12:471-508.
    • (1988) Prog Phys Geogr , vol.12 , pp. 471-508
    • Oke, T.R.1
  • 9
    • 0034082844 scopus 로고    scopus 로고
    • Physically-based scheme for the urban energy budget in atmospheric models
    • Masson V.A. Physically-based scheme for the urban energy budget in atmospheric models. Bound-Lay Meteorol 2000, 94:357-397.
    • (2000) Bound-Lay Meteorol , vol.94 , pp. 357-397
    • Masson, V.A.1
  • 10
    • 0036820549 scopus 로고    scopus 로고
    • Evaluation of the town energy balance (TEB) scheme with direct measurements from dry districts in two cities
    • Masson V., Grimmond C.S.B., Oke T.R. Evaluation of the town energy balance (TEB) scheme with direct measurements from dry districts in two cities. J Appl Meteorol 2002, 41:1011-1026.
    • (2002) J Appl Meteorol , vol.41 , pp. 1011-1026
    • Masson, V.1    Grimmond, C.S.B.2    Oke, T.R.3
  • 11
    • 1842832235 scopus 로고    scopus 로고
    • Modelling the surface energy balance of the core of an old Mediterranean city: Marseille
    • Lemonsu A., Grimmond C.S.B., Masson V. Modelling the surface energy balance of the core of an old Mediterranean city: Marseille. J Appl Meteorol 2004, 43:312-327.
    • (2004) J Appl Meteorol , vol.43 , pp. 312-327
    • Lemonsu, A.1    Grimmond, C.S.B.2    Masson, V.3
  • 12
    • 58149398467 scopus 로고    scopus 로고
    • Simulation of fall and winter surface energy balance over a dense urban area using the TEB scheme
    • Pigeon G., Moscicki A.M., Voogt J.A., Masson V. Simulation of fall and winter surface energy balance over a dense urban area using the TEB scheme. Meteorol Atmos Phy 2008, 102:159-171.
    • (2008) Meteorol Atmos Phy , vol.102 , pp. 159-171
    • Pigeon, G.1    Moscicki, A.M.2    Voogt, J.A.3    Masson, V.4
  • 13
    • 0141819352 scopus 로고    scopus 로고
    • Development of a numerical simulation system for comprehensive assessments of urban warming countermeasures including their impacts upon the urban building's energy-demands
    • Kikegawa Y., Genchi Y., Yoshikado H., Kondo H. Development of a numerical simulation system for comprehensive assessments of urban warming countermeasures including their impacts upon the urban building's energy-demands. Appl Energy 2003, 76:449-466.
    • (2003) Appl Energy , vol.76 , pp. 449-466
    • Kikegawa, Y.1    Genchi, Y.2    Yoshikado, H.3    Kondo, H.4
  • 14
    • 73149105278 scopus 로고    scopus 로고
    • A new building energy model coupled with an urban canopy parameterization for urban climate simulations-part I. Formulation, verification and a sensitive analysis of the model
    • Salamanca F., Krpo A., Martilli A., Clappier A. A new building energy model coupled with an urban canopy parameterization for urban climate simulations-part I. Formulation, verification and a sensitive analysis of the model. Theor Appl Climatol 2010, 10.1007/s00704-009-0142-9.
    • (2010) Theor Appl Climatol
    • Salamanca, F.1    Krpo, A.2    Martilli, A.3    Clappier, A.4
  • 15
    • 34848834156 scopus 로고    scopus 로고
    • Changes in year-round air temperature and annual energy consumption in office building areas by urban heat-island countermeasures and energy-saving measures
    • Ihara T., Kikegawa Y., Asahi K., Genchi Y., Kondo H. Changes in year-round air temperature and annual energy consumption in office building areas by urban heat-island countermeasures and energy-saving measures. Appl Energy 2008, 85:12-25.
    • (2008) Appl Energy , vol.85 , pp. 12-25
    • Ihara, T.1    Kikegawa, Y.2    Asahi, K.3    Genchi, Y.4    Kondo, H.5
  • 16
    • 73149101472 scopus 로고    scopus 로고
    • A new building energy model coupled with an urban canopy parameterization for urban climate simulations-part II. Validation with one dimension off-line simulations
    • Salamanca F., Martilli A. A new building energy model coupled with an urban canopy parameterization for urban climate simulations-part II. Validation with one dimension off-line simulations. Theor Appl Climatol 2010, 10.1007/s00704-009-0143-8.
    • (2010) Theor Appl Climatol
    • Salamanca, F.1    Martilli, A.2
  • 18
    • 80051663853 scopus 로고    scopus 로고
    • Combining a detailed building energy model with a physically-based urban canopy model
    • Bueno B., Norford L., Pigeon G., Britter R. Combining a detailed building energy model with a physically-based urban canopy model. Bound-Lay Meteorol 2011, 10.1007/s10546-011-9620-6.
    • (2011) Bound-Lay Meteorol
    • Bueno, B.1    Norford, L.2    Pigeon, G.3    Britter, R.4
  • 19
    • 12144258318 scopus 로고
    • A parametric model of vertical eddy uxes in the atmosphere
    • Louis J.F. A parametric model of vertical eddy uxes in the atmosphere. Bound-Lay Meteorol 1979, 17:187-202.
    • (1979) Bound-Lay Meteorol , vol.17 , pp. 187-202
    • Louis, J.F.1
  • 20
    • 58149394854 scopus 로고    scopus 로고
    • The canopy and aerosol particles interactions in Toulouse urban layer (CAPITOUL) experiment
    • Masson V., Gomes L., Pigeon G., Liousse C., Pont V., Lagouarde J.-P., et al. The canopy and aerosol particles interactions in Toulouse urban layer (CAPITOUL) experiment. Meteorol Atmos Phys 2008, 102:135-157.
    • (2008) Meteorol Atmos Phys , vol.102 , pp. 135-157
    • Masson, V.1    Gomes, L.2    Pigeon, G.3    Liousse, C.4    Pont, V.5    Lagouarde, J.-P.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.