메뉴 건너뛰기




Volumn 114, Issue 3, 2012, Pages 494-496

A matter of conscience: A call to action for system improvements involving epidural and spinal catheters

Author keywords

[No Author keywords available]

Indexed keywords

ANTIHYPERTENSIVE AGENT; CHLORHEXIDINE; HYPERTENSIVE AGENT; NEUROMUSCULAR BLOCKING AGENT; TRANEXAMIC ACID;

EID: 84857582674     PISSN: 00032999     EISSN: None     Source Type: Journal    
DOI: 10.1213/ANE.0b013e318245c1b8     Document Type: Editorial
Times cited : (6)

References (15)
  • 1
    • 79959653522 scopus 로고    scopus 로고
    • Of parachutes and patient care: A call to action
    • Berkowitz RL. Of parachutes and patient care: a call to action. Am J Obstetrics and Gynecology 2011;205:7-9
    • (2011) Am J Obstetrics and Gynecology , vol.205 , pp. 7-9
    • Berkowitz, R.L.1
  • 2
    • 78549291695 scopus 로고    scopus 로고
    • An iterative process of global quality improvement: The International Standards for a Safe Practice of Anesthesia
    • Merry AF, Cooper JB, Soyannwo O, Wilson IH, Eichhorn JH. An iterative process of global quality improvement: the International Standards for a Safe Practice of Anesthesia. Can J Anaesth 2010;57:1021-6
    • (2010) Can J Anaesth , vol.57 , pp. 1021-1026
    • Merry, A.F.1    Cooper, J.B.2    Soyannwo, O.3    Wilson, I.H.4    Eichhorn, J.H.5
  • 3
    • 0027397670 scopus 로고
    • International standards for the safe practice of anesthesia
    • International Taskforce on Anaesthesia Safet.y.
    • International Taskforce on Anaesthesia Safety. International standards for the safe practice of anesthesia. Eur J Anaesthesiol 1993;10:12-5
    • (1993) Eur J Anaesthesiol , vol.10 , pp. 12-15
  • 5
    • 0035167574 scopus 로고    scopus 로고
    • Inadvertent caudal epidural injection of cefazolin
    • McHaourab A, Ruiz F. Inadvertent caudal epidural injection of cefazolin. Anesthesiology 2001;94:184
    • (2001) Anesthesiology , vol.94 , pp. 184
    • McHaourab, A.1    Ruiz, F.2
  • 6
    • 39049188862 scopus 로고    scopus 로고
    • Accidental administration of atracurium through an epidural catheter
    • Sanchez-Bailen MJ, Roca P, Beniloch R. Accidental administration of atracurium through an epidural catheter. Rev Esp Anestesiol Reanim 2006;53:4555-6
    • (2006) Rev Esp Anestesiol Reanim , vol.53 , pp. 4555-4556
    • Sanchez-Bailen, M.J.1    Roca, P.2    Beniloch, R.3
  • 7
    • 0034521093 scopus 로고    scopus 로고
    • Analysis of inadvertent epidural injection of drugs
    • Kasaba T, Uehara K, Katsuki H, Ono Y, Takasaki M. Analysis of inadvertent epidural injection of drugs. Masui 2000;49: 1391-4
    • (2000) Masui , vol.49 , pp. 1391-1394
    • Kasaba, T.1    Uehara, K.2    Katsuki, H.3    Ono, Y.4    Takasaki, M.5
  • 8
    • 33846872530 scopus 로고    scopus 로고
    • Intravenous propofol precipitates the hypotension induced by inadvertent epidural thiopental injection
    • Huang SY, Wang CC, Chang WK, Chan KH, Chu CC. Intravenous propofol precipitates the hypotension induced by inadvertent epidural thiopental injection. Acta Anaesthesiol Taiwan 2006;44:239-42
    • (2006) Acta Anaesthesiol Taiwan , vol.44 , pp. 239-242
    • Huang, S.Y.1    Wang, C.C.2    Chang, W.K.3    Chan, K.H.4    Chu, C.C.5
  • 9
    • 66349098659 scopus 로고    scopus 로고
    • Polymyoclonus seizure resulting from accidental injection of tranexamic acid in spinal anesthesia
    • Mohseni K, Jafari A, Nobahar MR, Arami A. Polymyoclonus seizure resulting from accidental injection of tranexamic acid in spinal anesthesia. Anesth Analg 2009;108:1984-6
    • (2009) Anesth Analg , vol.108 , pp. 1984-1986
    • Mohseni, K.1    Jafari, A.2    Nobahar, M.R.3    Arami, A.4
  • 10
    • 78349301141 scopus 로고    scopus 로고
    • National Patient Safety Agency patient Safety Alert. London: National Patient Safety Agency
    • National Patient Safety Agency patient Safety Alert. Safer Spinal, Epidural and Regional Anaesthesia Devices-Part A. London: National Patient Safety Agency, 2009
    • (2009) Safer Spinal, Epidural and Regional Anaesthesia Devices-Part A.
  • 11
    • 79955808455 scopus 로고    scopus 로고
    • Critical incident reports concerning anaesthetic equipment: Analysis of the UK National Reporting and Learning System (NRLS) data from 2006-2008
    • Cassidy CJ, Smith A, Arnot-Smith J. Critical incident reports concerning anaesthetic equipment: analysis of the UK National Reporting and Learning System (NRLS) data from 2006-2008. Anaesthesia 2011;66:879-88
    • (2011) Anaesthesia , vol.66 , pp. 879-888
    • Cassidy, C.J.1    Smith, A.2    Arnot-Smith, J.3
  • 12
    • 84857516008 scopus 로고    scopus 로고
    • National Patient Safety Agency. Patient Safety Alerts NPSA/2009/PSA004A and NPSA/2011/PSA001. London: National Patient Safety Agency
    • National Patient Safety Agency. Patient Safety Alerts NPSA/2009/PSA004A and NPSA/2011/PSA001. London: National Patient Safety Agency
  • 13
    • 78049504199 scopus 로고    scopus 로고
    • A simulation-based evaluation of two proposed alternatives to Luer devices for use in neuraxial anaesthesia
    • Cook TM, Payne S, Skryabina E, Hurford D, Clow E, Georgiou A. A simulation-based evaluation of two proposed alternatives to Luer devices for use in neuraxial anaesthesia. Anaesthesia 2010;65:1069-79
    • (2010) Anaesthesia , vol.65 , pp. 1069-1079
    • Cook, T.M.1    Payne, S.2    Skryabina, E.3    Hurford, D.4    Clow, E.5    Georgiou, A.6
  • 15
    • 0036072587 scopus 로고    scopus 로고
    • Safer epidural and spinal connectors
    • Lanigan CJ Safer epidural and spinal connectors, Anaesthesia 2002;57:567-71
    • (2002) Anaesthesia , vol.57 , pp. 567-571
    • Lanigan, C.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.