메뉴 건너뛰기




Volumn 12, Issue 2, 2012, Pages 1816-1826

Evaluation of electrical and optical plethysmography sensors for noninvasive monitoring of hemoglobin concentration

Author keywords

Capacitance; Hemoglobin; Noninvasive; Plethysmography

Indexed keywords

HEMOGLOBIN;

EID: 84857577940     PISSN: 14248220     EISSN: None     Source Type: Journal    
DOI: 10.3390/s120201816     Document Type: Article
Times cited : (20)

References (14)
  • 1
    • 84857590198 scopus 로고
    • ICN Fact Sheet Number One; FAO/WHO: Rome, Italy
    • Preventing Micronutrient Deficiencies; ICN Fact Sheet Number One; FAO/WHO: Rome, Italy, 1992.
    • (1992) Preventing Micronutrient Deficiencies
  • 3
    • 0033205881 scopus 로고    scopus 로고
    • Utility of HemoCue in Estimation of Hemoglobin against Standard Blood Cell Counter Method
    • Prakash, S.; Kapil, U.; Singh, G.; Dwivedi, S.N. Tandon, M. Utility of HemoCue in Estimation of Hemoglobin against Standard Blood Cell Counter Method. J. Assoc. Phys. India 1999, 47, 995-997.
    • (1999) J. Assoc. Phys. India. , vol.47 , pp. 995-997
    • Prakash, S.1    Kapil, U.2    Singh, G.3    Dwivedi, S.N.4    Tandon, M.5
  • 4
    • 71849097489 scopus 로고    scopus 로고
    • Estimation of Blood Hemoglobin Concentration Using the HemoCue during Caesarean Section: The Effect of Sampling Site
    • Richards, N.A.; Boyce, H.; Yentis, S.M. Estimation of Blood Hemoglobin Concentration Using the HemoCue during Caesarean Section: The Effect of Sampling Site. Int. J. Obstet. Anesth. 2010, 19, 67-70.
    • (2010) Int. J. Obstet. Anesth. , vol.19 , pp. 67-70
    • Richards, N.A.1    Boyce, H.2    Yentis, S.M.3
  • 5
    • 56849093676 scopus 로고    scopus 로고
    • The Measurement of Dyshemoglobins and Total Hemoglobin by Pulse Oximetry
    • Barker, S.J.; Badal, J.J. The Measurement of Dyshemoglobins and Total Hemoglobin by Pulse Oximetry. Curr. Opin. Anasthesiol. 2008, 21, 805-810.
    • (2008) Curr. Opin. Anasthesiol. , vol.21 , pp. 805-810
    • Barker, S.J.1    Badal, J.J.2
  • 6
    • 78650304152 scopus 로고    scopus 로고
    • The Accuracy of Noninvasive and Continuous Total Hemoglobin Measurement by Pulse CO-Oximetry in Human Subjects Undergoing Hemodilution
    • Macknet, M.R.; Allard, M.; Applegate, R.L., 2nd; Rook, J. The Accuracy of Noninvasive and Continuous Total Hemoglobin Measurement by Pulse CO-Oximetry in Human Subjects Undergoing Hemodilution. Anesth. Analg. 2010, 111, 1424-1426.
    • (2010) Anesth. Analg. , vol.111 , pp. 1424-1426
    • Macknet, M.R.1    Allard, M.2    Applegate II, R.L.3    Rook, J.4
  • 7
    • 0000402710 scopus 로고
    • Electrical Impedance Plethysmography: A Physical and Physiologic Approach to Peripheral Vascular Study
    • Nyboer, J.; Kreider, M.M.; Hannapel, L. Electrical Impedance Plethysmography: A Physical and Physiologic Approach to Peripheral Vascular Study. Circulation 1950, 2, 811-821.
    • (1950) Circulation , vol.2 , pp. 811-821
    • Nyboer, J.1    Kreider, M.M.2    Hannapel, L.3
  • 10
    • 0022026327 scopus 로고
    • The Contribution of Vessel Volume Change and Blood Resistivity Change to the Electrical Impedance Pulse
    • Ravi Shankar, T.M.; Webster, J.G.; Shao, S. The Contribution of Vessel Volume Change and Blood Resistivity Change to the Electrical Impedance Pulse. IEEE Trans. Biomed. Eng. 1985, BME-32, 192-198.
    • (1985) IEEE Trans. Biomed. Eng. , vol.BME-32 , pp. 192-198
    • Ravi Shankar, T.M.1    Webster, J.G.2    Shao, S.3
  • 11
    • 0014699588 scopus 로고
    • A Direct Reading Capacitance Plethysmograph
    • Wood, J.R.; Hyman, C. A Direct Reading Capacitance Plethysmograph. Med. Biol. Eng. Comp. 1970, 8, 59-70.
    • (1970) Med. Biol. Eng. Comp. , vol.8 , pp. 59-70
    • Wood, J.R.1    Hyman, C.2
  • 12
    • 0037297655 scopus 로고    scopus 로고
    • Dielectric Properties of Blood: An Investigation of Haematocrit Dependence
    • Jaspard, F.; Nadi, M.; Rouane, A. Dielectric Properties of Blood: An Investigation of Haematocrit Dependence. Physiol. Meas. 2003, 24, 137-147.
    • (2003) Physiol. Meas. , vol.24 , pp. 137-147
    • Jaspard, F.1    Nadi, M.2    Rouane, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.