메뉴 건너뛰기




Volumn 148, Issue 4, 2012, Pages 507-513

Dose conversion coefficients for neutron exposure to the lens of the human eye

Author keywords

[No Author keywords available]

Indexed keywords

ABSORPTION; ALGORITHM; CATARACT; HUMAN; IMAGE QUALITY; LENS; METHODOLOGY; MONTE CARLO METHOD; NEUTRON; NOTE; RADIATION DOSE; RADIATION EXPOSURE; RADIATION PROTECTION; RADIOMETRY; STATISTICAL MODEL; THEORETICAL MODEL;

EID: 84857561960     PISSN: 01448420     EISSN: 17423406     Source Type: Journal    
DOI: 10.1093/rpd/ncr202     Document Type: Note
Times cited : (22)

References (10)
  • 2
    • 51749085638 scopus 로고    scopus 로고
    • Chodick, G. et al. Risk of cataract after exposure to low doses of ionizing radiation: a 20-year prospective cohort study among US radiologic technologists. Am. J. Epidemiol. 168(6), 620-631 (2008).
    • (2008) Am. J. Epidemiol. , vol.168 , Issue.6 , pp. 620-631
    • Chodick, G.1
  • 3
    • 33645104242 scopus 로고    scopus 로고
    • Revisions to the ORNL series of adult and pediatric computational phantoms for use with the MIRD schema
    • Han, E. Y., Bolch, W. E. and Eckerman, K. F. Revisions to the ORNL series of adult and pediatric computational phantoms for use with the MIRD schema. Health Phys. 90(4), 337-356 (2006).
    • (2006) Health Phys , vol.90 , Issue.4 , pp. 337-356
    • Han, E.Y.1    Bolch, W.E.2    Eckerman, K.F.3
  • 4
    • 77953551346 scopus 로고    scopus 로고
    • Los Alamos National Laboratory (Distributed by the Radiation Safety Information Computing Center, Oak Ridge National Laboratory)
    • Los Alamos National Laboratory. RSICC Code Package CCC-740 (Distributed by the Radiation Safety Information Computing Center, Oak Ridge National Laboratory) (2008).
    • (2008) RSICC Code Package CCC-740
  • 5
    • 0016662525 scopus 로고
    • Dimensions of the human eye relevant to radiation protection
    • Charles, M. W. and Brown, N. Dimensions of the human eye relevant to radiation protection. Phys. Med. Biol. 20, 202-218 (1975).
    • (1975) Phys. Med. Biol. , vol.20 , pp. 202-218
    • Charles, M.W.1    Brown, N.2
  • 6
    • 70249129104 scopus 로고    scopus 로고
    • Dose conversion coefficients for electron exposure of the human eye lense
    • Behrens, R., Dietze, G. and Zankl, M. Dose conversion coefficients for electron exposure of the human eye lense. Phys. Med. Biol. 54, 4069-4087 (2009).
    • (2009) Phys. Med. Biol. , vol.54 , pp. 4069-4087
    • Behrens, R.1    Dietze, G.2    Zankl, M.3
  • 7
    • 33644511162 scopus 로고    scopus 로고
    • Report No LA-CP-07-1473 (Los Alamos National Laboratory)
    • Waters, L. MCNPX User's Manual, Version 2.6.0. Report No LA-CP-07-1473 (Los Alamos National Laboratory) (2008).
    • (2008) MCNPX User's Manual, Version 2.6.0
    • Waters, L.1
  • 8
    • 30844453628 scopus 로고    scopus 로고
    • ENDF/B-VI release 8 (last release of ENDF/B-VI)
    • Report No. IAEA-NDS-100, Rev. 11 (IAEA)
    • Lemmel, H. D., McLaughlin, P. K. and Pronyaev, V. G. ENDF/B-VI release 8 (last release of ENDF/B-VI). Report No. IAEA-NDS-100, Rev. 11 (IAEA) (2001).
    • (2001)
    • Lemmel, H.D.1    McLaughlin, P.K.2    Pronyaev, V.G.3
  • 10
    • 63649107293 scopus 로고    scopus 로고
    • Fluence-to-dose conversion coefficients for neutrons and protons calculated using the PHITS codes and ICRP/ICRU adult reference computational phantoms
    • Sato, T., Endo, A., Zankl, M., Petoussi-Henss, N. and Niita, K. Fluence-to-dose conversion coefficients for neutrons and protons calculated using the PHITS codes and ICRP/ICRU adult reference computational phantoms. Phys. Med. Biol. 54, 1907-2014 (2009).
    • (2009) Phys. Med. Biol. , vol.54 , pp. 1907-2014
    • Sato, T.1    Endo, A.2    Zankl, M.3    Petoussi-Henss, N.4    Niita, K.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.