메뉴 건너뛰기




Volumn , Issue , 2011, Pages 377-380

Minimizing MOSFET power losses in near-field electromagnetic energy-harnessing ICs

Author keywords

Contactless charging; Inductive (electromagnetic) coupling; Inductive power transfer; Wireless power transfer

Indexed keywords

COUPLINGS; ELECTROMAGNETIC INDUCTION; ELECTROMAGNETIC WAVES; ENERGY TRANSFER; INDUCTIVE POWER TRANSMISSION; INTEGRATED CIRCUITS; SECONDARY BATTERIES; TIMING CIRCUITS;

EID: 84857395890     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/isocc.2011.6138789     Document Type: Conference Paper
Times cited : (3)

References (15)
  • 1
    • 34247889987 scopus 로고    scopus 로고
    • Feedback analysis and design of RF power links for low-power bionic systems
    • DOI 10.1109/TBCAS.2007.893180
    • M.W. Baker and R. Sarpeshkar, "Feedback Analysis and Design of RF Power Links for Low-Power Bionic Systems," IEEE Trans. Biomed. Circuits and Syst., vol. 1, pp. 28-38, 2007. (Pubitemid 46691400)
    • (2007) IEEE Transactions on Biomedical Circuits and Systems , vol.1 , Issue.1 , pp. 28-38
    • Baker, M.W.1    Sarpeshkar, R.2
  • 2
    • 77951667224 scopus 로고    scopus 로고
    • An RFID-Based Closed-Loop Wireless Power Transmission System for Biomedical Applications
    • M. Kiani and M. Ghovanloo, "An RFID-Based Closed-Loop Wireless Power Transmission System for Biomedical Applications," IEEE Trans. Circuits and Syst. II, vol. 57, pp. 260-264, 2010.
    • (2010) IEEE Trans. Circuits and Syst. II , vol.57 , pp. 260-264
    • Kiani, M.1    Ghovanloo, M.2
  • 3
    • 27644587657 scopus 로고    scopus 로고
    • Design and analysis of an adaptive transcutaneous power telemetry for biomedical implants
    • DOI 10.1109/TCSI.2005.852923
    • W. Guoxing, L. Wentai, M. Sivaprakasam, and G. A. Kendir, "Design and analysis of an adaptive transcutaneous power telemetry for biomedical implants," IEEE Trans. Circuits and Syst. I, vol. 52, pp. 2109-2117, 2005. (Pubitemid 41556096)
    • (2005) IEEE Transactions on Circuits and Systems I: Regular Papers , vol.52 , Issue.10 , pp. 2109-2117
    • Wang, G.1    Liu, W.2    Sivaprakasam, M.3    Kendir, G.A.4
  • 4
    • 77958152372 scopus 로고    scopus 로고
    • Circuit Design Advances for Wireless Sensing Applications
    • G. Chen, et al., "Circuit Design Advances for Wireless Sensing Applications," Proc. of the IEEE, vol. 98, pp. 1808-1827, 2010.
    • (2010) Proc. of the IEEE , vol.98 , pp. 1808-1827
    • Chen, G.1
  • 7
    • 67349208924 scopus 로고    scopus 로고
    • Mutual Inductance Calculation of Movable Planar Coils on Parallel Surfaces
    • Y.P. Su, X. Liu, and S.Y.R. Hui, "Mutual Inductance Calculation of Movable Planar Coils on Parallel Surfaces," IEEE Trans. Power Electron., vol. 24, pp. 1115-1123, 2009.
    • (2009) IEEE Trans. Power Electron. , vol.24 , pp. 1115-1123
    • Su, Y.P.1    Liu, X.2    Hui, S.Y.R.3
  • 10
    • 36348980385 scopus 로고    scopus 로고
    • Simulation study and experimental verification of a universal contactless battery charging platform with localized charging features
    • DOI 10.1109/TPEL.2007.909301
    • X. Liu and S.Y. Hui, "Simulation study and experimental verification of a universal contactless battery charging platform with localized charging features," IEEE Trans. Power Electron., vol. 22, pp. 2202-2210, Nov. 2007. (Pubitemid 350154054)
    • (2007) IEEE Transactions on Power Electronics , vol.22 , Issue.6 , pp. 2202-2210
    • Liu, X.1    Hui, S.Y.2
  • 11
    • 58049113153 scopus 로고    scopus 로고
    • Optimal coupling condition of IPT system for achieving maximum power transfer
    • H. L. Li, et al., "Optimal coupling condition of IPT system for achieving maximum power transfer," Electron. Letters, vol. 45, pp. 76-77, 2009.
    • (2009) Electron. Letters , vol.45 , pp. 76-77
    • Li, H.L.1
  • 12
    • 67649647608 scopus 로고    scopus 로고
    • An Efficiency-Enhanced CMOS Rectifier with Unbalanced-Biased Comparators for Transcutaneous-Powered High-Current Implants
    • S. Guo and H. Lee, "An Efficiency-Enhanced CMOS Rectifier With Unbalanced-Biased Comparators for Transcutaneous-Powered High-Current Implants," IEEE J. Solid-State Circuits, vol. 44, pp. 1796-1804, 2009.
    • (2009) IEEE J. Solid-State Circuits , vol.44 , pp. 1796-1804
    • Guo, S.1    Lee, H.2
  • 13
    • 36249007065 scopus 로고    scopus 로고
    • A wireless power interface for rechargeable battery operated medical implants
    • DOI 10.1109/TCSII.2007.901613
    • P. Li and R. Bashirullah, "A Wireless Power Interface for Rechargeable Battery Operated Medical Implants," IEEE Trans. Circuits and Syst. II, vol. 54, pp. 912-916, 2007. (Pubitemid 350129796)
    • (2007) IEEE Transactions on Circuits and Systems II: Express Briefs , vol.54 , Issue.10 , pp. 912-916
    • Li, P.1    Bashirullah, R.2
  • 14
    • 60149089827 scopus 로고    scopus 로고
    • Analysis, Design, and Control of a Transcutaneous Power Regulator for Artificial Hearts
    • Q. Chen, et al., "Analysis, Design, and Control of a Transcutaneous Power Regulator for Artificial Hearts," IEEE Trans. Biomed. Circuits and Syst., vol. 3, pp. 23-31, 2009.
    • (2009) IEEE Trans. Biomed. Circuits and Syst. , vol.3 , pp. 23-31
    • Chen, Q.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.