메뉴 건너뛰기




Volumn 56, Issue 3, 2012, Pages 564-570

Discordance in fibrosis staging between liver biopsy and transient elastography using the FibroScan XL probe

Author keywords

Biomarker; Biopsy; Fibrosis; Stiffness

Indexed keywords

ADULT; ARTICLE; BODY MASS; CONTROLLED STUDY; DIAGNOSTIC TEST ACCURACY STUDY; DISEASE SEVERITY; ELASTOGRAPHY; FEMALE; HUMAN; HUMAN TISSUE; LIVER BIOPSY; LIVER FIBROSIS; MAJOR CLINICAL STUDY; MALE; NONALCOHOLIC FATTY LIVER; OBESITY; PREVALENCE; PRIORITY JOURNAL; RISK FACTOR; STAGING; VIRUS HEPATITIS;

EID: 84857369747     PISSN: 01688278     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jhep.2011.10.007     Document Type: Article
Times cited : (121)

References (36)
  • 2
    • 42149189962 scopus 로고    scopus 로고
    • Utilization rates, complications and costs of percutaneous liver biopsy: A population-based study including 4275 biopsies
    • R.P. Myers, A. Fong, and A.A. Shaheen Utilization rates, complications and costs of percutaneous liver biopsy: a population-based study including 4275 biopsies Liver Int 28 2008 705 712
    • (2008) Liver Int , vol.28 , pp. 705-712
    • Myers, R.P.1    Fong, A.2    Shaheen, A.A.3
  • 3
    • 0345017740 scopus 로고    scopus 로고
    • Sampling variability of liver fibrosis in chronic hepatitis C
    • P. Bedossa, D. Dargere, and V. Paradis Sampling variability of liver fibrosis in chronic hepatitis C Hepatology 38 2003 1449 1457
    • (2003) Hepatology , vol.38 , pp. 1449-1457
    • Bedossa, P.1    Dargere, D.2    Paradis, V.3
  • 4
    • 0036792679 scopus 로고    scopus 로고
    • Sampling error and intraobserver variation in liver biopsy in patients with chronic HCV infection
    • A. Regev, M. Berho, and L.J. Jeffers Sampling error and intraobserver variation in liver biopsy in patients with chronic HCV infection Am J Gastroenterol 97 2002 2614 2618
    • (2002) Am J Gastroenterol , vol.97 , pp. 2614-2618
    • Regev, A.1    Berho, M.2    Jeffers, L.J.3
  • 5
    • 81155162421 scopus 로고    scopus 로고
    • Biomarkers of liver fibrosis: What lies beneath the receiver operating characteristic curve?
    • I.N. Guha, R.P. Myers, and K. Patel Biomarkers of liver fibrosis: what lies beneath the receiver operating characteristic curve? Hepatology 54 2011 1454 1462
    • (2011) Hepatology , vol.54 , pp. 1454-1462
    • Guha, I.N.1    Myers, R.P.2    Patel, K.3
  • 6
    • 66749181710 scopus 로고    scopus 로고
    • Noninvasive diagnosis of nonalcoholic fatty liver disease
    • R.P. Myers Noninvasive diagnosis of nonalcoholic fatty liver disease Ann Hepatol 8 2009 S25 33
    • (2009) Ann Hepatol , vol.8 , pp. 25-33
    • Myers, R.P.1
  • 7
    • 41249100719 scopus 로고    scopus 로고
    • Non-invasive evaluation of liver fibrosis using transient elastography
    • L. Castera, X. Forns, and A. Alberti Non-invasive evaluation of liver fibrosis using transient elastography J Hepatol 48 2008 835 847
    • (2008) J Hepatol , vol.48 , pp. 835-847
    • Castera, L.1    Forns, X.2    Alberti, A.3
  • 8
    • 78449248606 scopus 로고    scopus 로고
    • Transient elastography for the noninvasive assessment of liver fibrosis: A multicentre Canadian study
    • R.P. Myers, M. Elkashab, and M. Ma Transient elastography for the noninvasive assessment of liver fibrosis: a multicentre Canadian study Can J Gastroenterol 24 2010 661 670
    • (2010) Can J Gastroenterol , vol.24 , pp. 661-670
    • Myers, R.P.1    Elkashab, M.2    Ma, M.3
  • 9
    • 41349094999 scopus 로고    scopus 로고
    • Performance of transient elastography for the staging of liver fibrosis: A meta-analysis
    • M. Friedrich-Rust, M.F. Ong, and S. Martens Performance of transient elastography for the staging of liver fibrosis: a meta-analysis Gastroenterology 134 2008 960 974
    • (2008) Gastroenterology , vol.134 , pp. 960-974
    • Friedrich-Rust, M.1    Ong, M.F.2    Martens, S.3
  • 10
    • 35448989237 scopus 로고    scopus 로고
    • FibroTest and FibroScan for the prediction of hepatitis C-related fibrosis: A systematic review of diagnostic test accuracy
    • A.A. Shaheen, A.F. Wan, and R.P. Myers FibroTest and FibroScan for the prediction of hepatitis C-related fibrosis: a systematic review of diagnostic test accuracy Am J Gastroenterol 102 2007 2589 2600
    • (2007) Am J Gastroenterol , vol.102 , pp. 2589-2600
    • Shaheen, A.A.1    Wan, A.F.2    Myers, R.P.3
  • 11
    • 50249178742 scopus 로고    scopus 로고
    • Reliability of transient elastography for the diagnosis of advanced fibrosis in chronic hepatitis C
    • U. Arena, F. Vizzutti, and J.G. Abraldes Reliability of transient elastography for the diagnosis of advanced fibrosis in chronic hepatitis C Gut 57 2008 1288 1293
    • (2008) Gut , vol.57 , pp. 1288-1293
    • Arena, U.1    Vizzutti, F.2    Abraldes, J.G.3
  • 12
    • 77950619459 scopus 로고    scopus 로고
    • Pitfalls of liver stiffness measurement: A 5-year prospective study of 13, 369 examinations
    • L. Castera, J. Foucher, and P.H. Bernard Pitfalls of liver stiffness measurement: a 5-year prospective study of 13, 369 examinations Hepatology 51 2010 828 835
    • (2010) Hepatology , vol.51 , pp. 828-835
    • Castera, L.1    Foucher, J.2    Bernard, P.H.3
  • 13
    • 33644521965 scopus 로고    scopus 로고
    • Prevalence and factors associated with failure of liver stiffness measurement using FibroScan in a prospective study of 2114 examinations
    • J. Foucher, L. Castera, and P.H. Bernard Prevalence and factors associated with failure of liver stiffness measurement using FibroScan in a prospective study of 2114 examinations Eur J Gastroenterol Hepatol 18 2006 411 412
    • (2006) Eur J Gastroenterol Hepatol , vol.18 , pp. 411-412
    • Foucher, J.1    Castera, L.2    Bernard, P.H.3
  • 14
    • 64749086294 scopus 로고    scopus 로고
    • Factors of accuracy of transient elastography (fibroscan) for the diagnosis of liver fibrosis in chronic hepatitis C
    • D. Lucidarme, J. Foucher, and B. Le Bail Factors of accuracy of transient elastography (fibroscan) for the diagnosis of liver fibrosis in chronic hepatitis C Hepatology 49 2009 1083 1089
    • (2009) Hepatology , vol.49 , pp. 1083-1089
    • Lucidarme, D.1    Foucher, J.2    Le Bail, B.3
  • 15
    • 78751566170 scopus 로고    scopus 로고
    • Prevalence, risk factors and causes of discordance in fibrosis staging by transient elastography and liver biopsy
    • R.P. Myers, P. Crotty, and G. Pomier-Layrargues Prevalence, risk factors and causes of discordance in fibrosis staging by transient elastography and liver biopsy Liver Int 30 2010 1471 1480
    • (2010) Liver Int , vol.30 , pp. 1471-1480
    • Myers, R.P.1    Crotty, P.2    Pomier-Layrargues, G.3
  • 16
    • 39849107267 scopus 로고    scopus 로고
    • Liver stiffness values in apparently healthy subjects: Influence of gender and metabolic syndrome
    • D. Roulot, S. Czernichow, and H. Le Clesiau Liver stiffness values in apparently healthy subjects: influence of gender and metabolic syndrome J Hepatol 48 2008 606 613
    • (2008) J Hepatol , vol.48 , pp. 606-613
    • Roulot, D.1    Czernichow, S.2    Le Clesiau, H.3
  • 17
    • 78851470616 scopus 로고    scopus 로고
    • Factors associated with unreliable liver stiffness measurement and its failure with transient elastography in the Chinese population
    • G.L. Wong, V.W. Wong, and A.M. Chim Factors associated with unreliable liver stiffness measurement and its failure with transient elastography in the Chinese population J Gastroenterol Hepatol 26 2011 300 305
    • (2011) J Gastroenterol Hepatol , vol.26 , pp. 300-305
    • Wong, G.L.1    Wong, V.W.2    Chim, A.M.3
  • 18
    • 77956015752 scopus 로고    scopus 로고
    • Feasibility of liver transient elastography with FibroScan using a new probe for obese patients
    • V. de Ledinghen, J. Vergniol, and J. Foucher Feasibility of liver transient elastography with FibroScan using a new probe for obese patients Liver Int 30 2010 1043 1048
    • (2010) Liver Int , vol.30 , pp. 1043-1048
    • De Ledinghen, V.1    Vergniol, J.2    Foucher, J.3
  • 19
    • 77957882755 scopus 로고    scopus 로고
    • Transient elastography with a new probe for obese patients for non-invasive staging of non-alcoholic steatohepatitis
    • M. Friedrich-Rust, H. Hadji-Hosseini, and S. Kriener Transient elastography with a new probe for obese patients for non-invasive staging of non-alcoholic steatohepatitis Eur Radiol 20 2010 2390 2396
    • (2010) Eur Radiol , vol.20 , pp. 2390-2396
    • Friedrich-Rust, M.1    Hadji-Hosseini, H.2    Kriener, S.3
  • 20
    • 84155188892 scopus 로고    scopus 로고
    • Feasibility and performance of the FibroScan XL probe for liver stiffness measurement in overweight and obese patients
    • doi:10.1002/hep.24624
    • Myers RP, Pomier-Layrargues G, Kirsch R, et al. Feasibility and performance of the FibroScan XL probe for liver stiffness measurement in overweight and obese patients. Hepatology 2011. doi:10.1002/hep.24624.
    • (2011) Hepatology
    • Myers, R.P.1    Pomier-Layrargues, G.2    Kirsch, R.3
  • 21
    • 79952706732 scopus 로고    scopus 로고
    • Etiology-related determinants of liver stiffness values in chronic viral hepatitis B or C
    • M. Fraquelli, C. Rigamonti, and G. Casazza Etiology-related determinants of liver stiffness values in chronic viral hepatitis B or C J Hepatol 54 2011 621 628
    • (2011) J Hepatol , vol.54 , pp. 621-628
    • Fraquelli, M.1    Rigamonti, C.2    Casazza, G.3
  • 22
    • 77954333877 scopus 로고    scopus 로고
    • Factors that affect the diagnostic accuracy of liver fibrosis measurement by Fibroscan in patients with chronic hepatitis B
    • S.U. Kim, Y.S. Seo, and J.Y. Cheong Factors that affect the diagnostic accuracy of liver fibrosis measurement by Fibroscan in patients with chronic hepatitis B Aliment Pharmacol Therap 32 2010 498 505
    • (2010) Aliment Pharmacol Therap , vol.32 , pp. 498-505
    • Kim, S.U.1    Seo, Y.S.2    Cheong, J.Y.3
  • 23
    • 75449091784 scopus 로고    scopus 로고
    • Diagnosis of fibrosis and cirrhosis using liver stiffness measurement in nonalcoholic fatty liver disease
    • V.W. Wong, J. Vergniol, and G.L. Wong Diagnosis of fibrosis and cirrhosis using liver stiffness measurement in nonalcoholic fatty liver disease Hepatology 51 2009 454 462
    • (2009) Hepatology , vol.51 , pp. 454-462
    • Wong, V.W.1    Vergniol, J.2    Wong, G.L.3
  • 24
    • 0037129380 scopus 로고    scopus 로고
    • Nonalcoholic fatty liver disease
    • P. Angulo Nonalcoholic fatty liver disease N Engl J Med 346 2002 1221 1231
    • (2002) N Engl J Med , vol.346 , pp. 1221-1231
    • Angulo, P.1
  • 25
    • 34548786091 scopus 로고    scopus 로고
    • Diagnostic accuracy of the aspartate aminotransferase-to-platelet ratio index for the prediction of hepatitis C-related fibrosis: A systematic review
    • A.A. Shaheen, and R.P. Myers Diagnostic accuracy of the aspartate aminotransferase-to-platelet ratio index for the prediction of hepatitis C-related fibrosis: a systematic review Hepatology 46 2007 912 921
    • (2007) Hepatology , vol.46 , pp. 912-921
    • Shaheen, A.A.1    Myers, R.P.2
  • 26
    • 20044374023 scopus 로고    scopus 로고
    • Design and validation of a histological scoring system for nonalcoholic fatty liver disease
    • D.E. Kleiner, E.M. Brunt, and M. Van Natta Design and validation of a histological scoring system for nonalcoholic fatty liver disease Hepatology 41 2005 1313 1321
    • (2005) Hepatology , vol.41 , pp. 1313-1321
    • Kleiner, D.E.1    Brunt, E.M.2    Van Natta, M.3
  • 27
    • 0028234491 scopus 로고
    • Intraobserver, interobserver variations in liver biopsy interpretation in patients with chronic hepatitis C
    • The French METAVIR Cooperative Study Group
    • The French METAVIR Cooperative Study Group Intraobserver, interobserver variations in liver biopsy interpretation in patients with chronic hepatitis C Hepatology 20 1994 15 20
    • (1994) Hepatology , vol.20 , pp. 15-20
  • 28
    • 0020083498 scopus 로고
    • The meaning and use of the area under a receiver operating characteristic (ROC) curve
    • J.A. Hanley, and B.J. McNeil The meaning and use of the area under a receiver operating characteristic (ROC) curve Radiology 143 1982 29 36
    • (1982) Radiology , vol.143 , pp. 29-36
    • Hanley, J.A.1    McNeil, B.J.2
  • 29
    • 0023710206 scopus 로고
    • Comparing the areas under two or more correlated receiver operating characteristic curves: A nonparametric approach
    • E.R. DeLong, D.M. DeLong, and D.L. Clarke-Pearson Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach Biometrics 44 1988 837 845
    • (1988) Biometrics , vol.44 , pp. 837-845
    • Delong, E.R.1    Delong, D.M.2    Clarke-Pearson, D.L.3
  • 30
    • 3242798959 scopus 로고    scopus 로고
    • Prospective analysis of discordant results between biochemical markers and biopsy in patients with chronic hepatitis C
    • T. Poynard, M. Munteanu, and F. Imbert-Bismut Prospective analysis of discordant results between biochemical markers and biopsy in patients with chronic hepatitis C Clin Chem 50 2004 1344 1355
    • (2004) Clin Chem , vol.50 , pp. 1344-1355
    • Poynard, T.1    Munteanu, M.2    Imbert-Bismut, F.3
  • 31
    • 33748745101 scopus 로고    scopus 로고
    • Validation and comparison of indexes for fibrosis and cirrhosis prediction in chronic hepatitis C patients: Proposal for a pragmatic approach classification without liver biopsies
    • M. Bourliere, G. Penaranda, and C. Renou Validation and comparison of indexes for fibrosis and cirrhosis prediction in chronic hepatitis C patients: proposal for a pragmatic approach classification without liver biopsies J Viral Hepat 13 2006 659 670
    • (2006) J Viral Hepat , vol.13 , pp. 659-670
    • Bourliere, M.1    Penaranda, G.2    Renou, C.3
  • 32
    • 12344309018 scopus 로고    scopus 로고
    • Prospective comparison of transient elastography, Fibrotest, APRI, and liver biopsy for the assessment of fibrosis in chronic hepatitis C
    • L. Castera, J. Vergniol, and J. Foucher Prospective comparison of transient elastography, Fibrotest, APRI, and liver biopsy for the assessment of fibrosis in chronic hepatitis C Gastroenterology 128 2005 343 350
    • (2005) Gastroenterology , vol.128 , pp. 343-350
    • Castera, L.1    Vergniol, J.2    Foucher, J.3
  • 33
    • 58149510576 scopus 로고    scopus 로고
    • Non-invasive assessment of liver fibrosis by stiffness measurement in patients with chronic hepatitis B
    • P. Marcellin, M. Ziol, and P. Bedossa Non-invasive assessment of liver fibrosis by stiffness measurement in patients with chronic hepatitis B Liver Int 29 2009 242 247
    • (2009) Liver Int , vol.29 , pp. 242-247
    • Marcellin, P.1    Ziol, M.2    Bedossa, P.3
  • 34
    • 56949103477 scopus 로고    scopus 로고
    • Exceeding the limits of liver histology markers
    • S.H. Mehta, B. Lau, and N.H. Afdhal Exceeding the limits of liver histology markers J Hepatol 50 2009 36 41
    • (2009) J Hepatol , vol.50 , pp. 36-41
    • Mehta, S.H.1    Lau, B.2    Afdhal, N.H.3
  • 35
    • 33847036602 scopus 로고    scopus 로고
    • Variability of the area under the receiver operating characteristic curves in the diagnostic evaluation of liver fibrosis markers: Impact of biopsy length and fragmentation
    • T. Poynard, P. Halfon, and L. Castera Variability of the area under the receiver operating characteristic curves in the diagnostic evaluation of liver fibrosis markers: impact of biopsy length and fragmentation Aliment Pharmacol Therap 25 2007 733 739
    • (2007) Aliment Pharmacol Therap , vol.25 , pp. 733-739
    • Poynard, T.1    Halfon, P.2    Castera, L.3
  • 36
    • 0042766810 scopus 로고    scopus 로고
    • Biochemical surrogate markers of liver fibrosis and activity in a randomized trial of peginterferon alfa-2b and ribavirin
    • T. Poynard, J. McHutchison, and M. Manns Biochemical surrogate markers of liver fibrosis and activity in a randomized trial of peginterferon alfa-2b and ribavirin Hepatology 38 2003 481 492
    • (2003) Hepatology , vol.38 , pp. 481-492
    • Poynard, T.1    McHutchison, J.2    Manns, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.