메뉴 건너뛰기




Volumn 13, Issue 1, 2012, Pages 81-85

Evaluation of the Biofidelity of the HIII and MIL-Lx Lower Leg Surrogates Under Axial Impact Loading

Author keywords

Anthropomorphic test device; Biofidelity; Impact loading; Injury risk; Lower leg

Indexed keywords

ACCELERATION; ARTICLE; AUDIOVISUAL EQUIPMENT; CADAVER; COMPARATIVE STUDY; EVALUATION; HUMAN; MECHANICAL STRESS; PATHOPHYSIOLOGY; PHYSIOLOGY; PROTECTIVE CLOTHING; REPRODUCIBILITY; RISK ASSESSMENT; STATISTICS; TIBIA; TIBIA FRACTURE; TRAFFIC ACCIDENT;

EID: 84857158367     PISSN: 15389588     EISSN: 1538957X     Source Type: Journal    
DOI: 10.1080/15389588.2011.623251     Document Type: Article
Times cited : (14)

References (15)
  • 1
    • 57449108685 scopus 로고    scopus 로고
    • Validation of lower limb surrogates as injury assessment tools in floor impacts due to anti-vehicular land mines
    • Bir, C, Barbir, A, Dosquet, F, Wilhelm, M, van der Horst, M and Wolfe, G. 2008. Validation of lower limb surrogates as injury assessment tools in floor impacts due to anti-vehicular land mines. Mil Med., 173: 1180-1184.
    • (2008) Mil Med. , vol.173 , pp. 1180-1184
    • Bir, C.1    Barbir, A.2    Dosquet, F.3    Wilhelm, M.4    van der Horst, M.5    Wolfe, G.6
  • 2
    • 84855881870 scopus 로고    scopus 로고
    • GESAC, Report GESAC-01-04, General Engineering and Systems Analysis Company, Inc. Prepared for NHTSA, Revision 2001.02. November
    • GESAC. Biomechanical Response Requirements of the THOR NHTSA Advanced Frontal Dummy. Report GESAC-01-04, General Engineering and Systems Analysis Company, Inc. Prepared for NHTSA, Revision 2001.02. November 2001.
    • (2001) Biomechanical Response Requirements of the THOR NHTSA Advanced Frontal Dummy
  • 11
    • 0033276727 scopus 로고    scopus 로고
    • Comparison of the THOR, HYBRID III and cadaver lower leg dynamic responses in dorsiflexion
    • Warrendale, Pa: Society of Automotive Engineers
    • Petit, P and Trosseille, X. Comparison of the THOR, HYBRID III and cadaver lower leg dynamic responses in dorsiflexion. 43rd Stapp Car Crash Conference Proceedings, Warrendale, Pa: Society of Automotive Engineers
    • 43rd Stapp Car Crash Conference Proceedings
    • Petit, P.1    Trosseille, X.2
  • 12
    • 77955106191 scopus 로고    scopus 로고
    • Development of an apparatus to produce fractures from short-duration high-impulse loading with an application in the lower leg
    • Quenneville, C E, Fraser, G S and Dunning, C E. 2010. Development of an apparatus to produce fractures from short-duration high-impulse loading with an application in the lower leg. J Biomech Eng., 132(1): 014502
    • (2010) J Biomech Eng. , vol.132 , Issue.1 , pp. 014502
    • Quenneville, C.E.1    Fraser, G.S.2    Dunning, C.E.3
  • 13
    • 78751618871 scopus 로고    scopus 로고
    • Injury tolerance criteria for short-duration axial impulse loading of the isolated tibia
    • Quenneville, C E, McLachlin, S D, Greeley, G S and Dunning, C E. 2011. Injury tolerance criteria for short-duration axial impulse loading of the isolated tibia. J Trauma., 70(1): E13-E18.
    • (2011) J Trauma. , vol.70 , Issue.1
    • Quenneville, C.E.1    McLachlin, S.D.2    Greeley, G.S.3    Dunning, C.E.4
  • 14
    • 0033276878 scopus 로고    scopus 로고
    • Development and design of Thor-Lx: the Thor lower extremity
    • Warrendale, Pa: Society of Automotive Engineers
    • Shams, T, Beach, DWhite, R P. Development and design of Thor-Lx: the Thor lower extremity. 43rd Stapp Car Crash Conference Proceedings,. Warrendale, Pa: Society of Automotive Engineers
    • 43rd Stapp Car Crash Conference Proceedings
    • Shams, T.1    Beach, D.2    White, R.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.