Uterine segmentation and volume measurement in uterine fibroid patients' MRI using Fuzzy C-Mean algorithm and morphological operations

Author keywords

Magnetic Resonance Imaging; Patients; Uterine Fibroids

Indexed keywords

ADULT; ARTICLE; AUTOMATION; CLINICAL ARTICLE; CLINICAL EVALUATION; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DIAGNOSTIC IMAGING; FEMALE; FUZZY SYSTEM; HUMAN; IMAGE ANALYSIS; IMAGE ENHANCEMENT; IMAGE PROCESSING; IMAGE QUALITY; INTERMETHOD COMPARISON; NUCLEAR MAGNETIC RESONANCE IMAGING; PATIENT ASSESSMENT; RELIABILITY; SENSITIVITY AND SPECIFICITY; STRUCTURE ANALYSIS; UTERINE ARTERY EMBOLIZATION; UTERUS MYOMA; VOLUMETRY;

EID: 84857081549     PISSN: 17351065     EISSN: None     Source Type: Journal    
DOI: 10.5812/kmp.iranjradiol.17351065.3142     Document Type: Article
Times cited : (28)

References (14)
  • 1
    • 0027174368 scopus 로고
    • Changing trends in treatment of leiomyomata uteri
    • Verkauf BS. Changing trends in treatment of leiomyomata uteri. Curr Opin Obstet Gynecol. 1993;5(3):301-10.
    • (1993) Curr Opin Obstet Gynecol. , vol.5 , Issue.3 , pp. 301-310
    • Verkauf, B.S.1
  • 2
    • 33751531250 scopus 로고    scopus 로고
    • Role of magnetic resonance imaging in patient selection for uterine artery embolization
    • Cura M, Cura A, Bugnone A. Role of magnetic resonance imaging in patient selection for uterine artery embolization. Acta Radiol. 2006;47(10):1105-14.
    • (2006) Acta Radiol. , vol.47 , Issue.10 , pp. 1105-1114
    • Cura, M.1    Cura, A.2    Bugnone, A.3
  • 8
    • 0345255220 scopus 로고    scopus 로고
    • VETOT, volume estimation and tracking over time: Framework and validation
    • Guyon JP, Foskey M, Kim J, Firat Z, Davis B, Haneke K, et al. VETOT, volume estimation and tracking over time: Framework and validation. MICCAI. 2003:142-9.
    • (2003) MICCAI , pp. 142-149
    • Guyon, J.P.1    Foskey, M.2    Kim, J.3    Firat, Z.4    Davis, B.5    Haneke, K.6
  • 13
    • 0032287848 scopus 로고    scopus 로고
    • Image segmentation via adaptive K-mean clustering and knowledge-based morphological operations with biomedical applications
    • Chen CW, Luo J, Parker KJ. Image segmentation via adaptive K-mean clustering and knowledge-based morphological operations with biomedical applications. IEEE Trans Image Process. 1998;7(12):1673-83.
    • (1998) IEEE Trans Image Process. , vol.7 , Issue.12 , pp. 1673-1683
    • Chen, C.W.1    Luo, J.2    Parker, K.J.3
  • 14
    • 0036425968 scopus 로고    scopus 로고
    • Improved optimization for the robust and accurate linear registration and motion correction of brain images
    • Jenkinson M, Bannister P, Brady M, Smith S. Improved optimization for the robust and accurate linear registration and motion correction of brain images. Neuroimage. 2002;17(2):825-41.
    • (2002) Neuroimage. , vol.17 , Issue.2 , pp. 825-841
    • Jenkinson, M.1    Bannister, P.2    Brady, M.3    Smith, S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.