1
-
-
33748312133
-
What is IAQ?
-
DOI 10.1111/j.1600-0668.2006.00437.x
-
P.O. Fanger What is IAQ? Indoor Air 16 5 2006 328 334 (Pubitemid 44327685)
-
(2006)
Indoor Air
, vol.16
, Issue.5
, pp. 328-334
-
-
Fanger, P.O.1
-
2
-
-
84857055505
-
-
USEPA, Indoor Air Quality Basics for Schools, United States Environmental Protection Agency, Washington, DC
-
USEPA, Indoor Air Quality Basics for Schools, United States Environmental Protection Agency, Washington, DC, 1996, http://www.epa.gov/iaq/pubs /.
-
(1996)
-
-
-
4
-
-
0037365997
-
Indoor air quality, ventilation and health symptoms in schools: An analysis of existing information
-
DOI 10.1034/j.1600-0668.2003.00153.x
-
J.M. Daisey, W.J. Angell, and M.G. Apte Indoor air quality, ventilation and health symptoms in schools: an analysis of existing information Indoor Air 3 1 2003 53 64 (Pubitemid 37463589)
-
(2003)
Indoor Air
, vol.13
, Issue.1
, pp. 53-64
-
-
Daisey, J.M.1
Angell, W.J.2
Apte, M.G.3
-
5
-
-
13544255585
-
Do indoor pollutants and thermal conditions in schools influence student performance? A critical review of the literature
-
DOI 10.1111/j.1600-0668.2004.00320.x
-
M.J. Mendell, and G.A. Heath Do indoor pollutants and thermal conditions in schools influence student performance? A critical review of the literature Indoor Air 5 1 2005 27 52 (Pubitemid 40223074)
-
(2005)
Indoor Air
, vol.15
, Issue.1
, pp. 27-52
-
-
Mendell, M.J.1
Heath, G.A.2
-
6
-
-
1442341728
-
Temperature and learning: An experimental study
-
R. Pepler Temperature and learning: an experimental study ASHRAE Transactions 4 2 1968 211 219
-
(1968)
ASHRAE Transactions
, vol.4
, Issue.2
, pp. 211-219
-
-
Pepler, R.1
-
7
-
-
0016313572
-
The effect of indoor relative humidity on absenteeism and colds in schools
-
G.H. Green The effect of indoor relative humidity on absenteeism and colds in schools ASHRAE Transactions 80 2 1974 131 141
-
(1974)
ASHRAE Transactions
, vol.80
, Issue.2
, pp. 131-141
-
-
Green, G.H.1
-
8
-
-
0022209557
-
Indoor relative humidities in winter and the related absenteeism
-
G.H. Green Indoor relative humidities in winter and the related absenteeism ASHRAE Transactions 1 1 1985 643 653 (Pubitemid 16497973)
-
(1985)
ASHRAE Transactions
, vol.91
, Issue.PART 1B
, pp. 643-653
-
-
Green, G.H.1
-
9
-
-
0025012409
-
Volatile organic compounds, respirable dust, and personal factors related to prevalence and incidence of sick building syndrome in primary schools
-
D. Norback, M. Torgen, and C. Edling Volatile organic compounds, respirable dust, and personal factors related to prevalence and incidence of sick building syndrome in primary schools British Medical Journal 47 11 1990 733
-
(1990)
British Medical Journal
, vol.47
, Issue.11
, pp. 733
-
-
Norback, D.1
Torgen, M.2
Edling, C.3
-
12
-
-
4544307329
-
Pupils health and performance due to renovation of schools
-
A. Myhrvold, and E. Olsen Pupils health and performance due to renovation of schools Proceedings of Healthy Buildings 1997 81 86
-
(1997)
Proceedings of Healthy Buildings
, pp. 81-86
-
-
Myhrvold, A.1
Olsen, E.2
-
13
-
-
0000731050
-
Subjective indoor air quality in schools in relation to exposure
-
G. Smedje, D. Norbck, and C. Edling Subjective indoor air quality in schools in relation to exposure Indoor Air 7 2 1997 143 150 (Pubitemid 127731725)
-
(1997)
Indoor Air
, vol.7
, Issue.2
, pp. 143-150
-
-
Smedje, G.1
-
14
-
-
0342264033
-
Health effects from air conditioning: Epidemiologic studies on schools and offices in Hong Kong
-
L. Koo, M. Luk, M. Mok, J. yuen, and T. yuen Health effects from air conditioning: epidemiologic studies on schools and offices in Hong Kong Proceedings of Indoor and Built Environment Problems in Asia at Kuala Lumpur 1997 4 5
-
(1997)
Proceedings of Indoor and Built Environment Problems in Asia at Kuala Lumpur
, pp. 4-5
-
-
Koo, L.1
Luk, M.2
Mok, M.3
Yuen, J.4
Yuen, T.5
-
15
-
-
0030774478
-
Nasal congestion in relation to low air exchange rate in schools. Evaluation by acoustic rhinometry
-
R. Wlinder, D. Norback, G. Wieslander, G. Smedje, and C. Erwall Nasal congestion in relation to low air exchange rate in schools: evaluation by acoustic rhinometry Acta Oto-Laryngologica 117 5 1997 724 727 (Pubitemid 27418203)
-
(1997)
Acta Oto-Laryngologica
, vol.117
, Issue.5
, pp. 724-727
-
-
Walinder, R.1
Norback, D.2
Wieslander, G.3
Smedje, G.4
Erwall, C.5
-
16
-
-
0001277118
-
Nasal mucosal swelling in relation to low air exchange rate in schools
-
R. Wlinder, D. Norbäck, G. Wieslander, G. Smedje, and C. Erwall Nasal mucosal swelling in relation to low air exchange rate in schools Indoor Air 7 3 1997 198 205
-
(1997)
Indoor Air
, vol.7
, Issue.3
, pp. 198-205
-
-
Wlinder, R.1
Norbäck, D.2
Wieslander, G.3
Smedje, G.4
Erwall, C.5
-
17
-
-
0031756668
-
Nasal patency and biomarkers in nasal lavage - The significance of air exchange rate and type of ventilation in schools
-
DOI 10.1007/s004200050309
-
R. Wlinder, D. Norbäck, G. Wieslander, G. Smedje, C. Erwall, and P. Venge Nasal patency and biomarkers in nasal lavage - the significance of air exchange rate and type of ventilation in schools International Archives of Occupational and Environmental Health 1 7 1998 479 486 (Pubitemid 28479432)
-
(1998)
International Archives of Occupational and Environmental Health
, vol.71
, Issue.7
, pp. 479-486
-
-
Walinder, R.1
Norback, D.2
Wieslander, G.3
Smedje, G.4
Erwall, C.5
Venge, P.6
-
18
-
-
1442292701
-
Building conditions and building-related symptoms in the Copenhagen school study
-
H. Meyer, L. Allermann, J. Nielsen, M. Hansen, S. Gravesen, P. Nielsen, P. Skov, and F. Gyntelberg Building conditions and building-related symptoms in the Copenhagen school study Indoor Air 2 1999 298 299
-
(1999)
Indoor Air
, Issue.2
, pp. 298-299
-
-
Meyer, H.1
Allermann, L.2
Nielsen, J.3
Hansen, M.4
Gravesen, S.5
Nielsen, P.6
Skov, P.7
Gyntelberg, F.8
-
19
-
-
0033141679
-
Indoor air quality investigations at five classrooms
-
S. Lee, and M. Chang Indoor air quality investigations at five classrooms Indoor Air 9 2 1999 134 138 (Pubitemid 129738239)
-
(1999)
Indoor Air
, vol.9
, Issue.2
, pp. 134-138
-
-
Lee, S.C.1
-
20
-
-
0034153768
-
Improved health after intervention in a school with moisture problems
-
M. hman, A. Lundin, V. Musabašíc, and E. Soderman Improved health after intervention in a school with moisture problems Indoor Air 0 1 2000 57 62
-
(2000)
Indoor Air
, vol.0
, Issue.1
, pp. 57-62
-
-
Hman, M.1
Lundin, A.2
Musabašíc, V.3
Soderman, E.4
-
21
-
-
0033627401
-
New ventilation systems at select schools in Sweden - Effects on asthma and exposure
-
G. Smedje, and D. Norbäck New ventilation systems at select schools in Sweden - effects on asthma and exposure Archives of Environmental Health: An International Journal 55 1 2000 18 25 (Pubitemid 30149249)
-
(2000)
Archives of Environmental Health
, vol.55
, Issue.1
, pp. 18-25
-
-
Smedje, G.1
Norback, D.2
-
22
-
-
0036602025
-
Daylighting and human performance
-
L. Heschong Daylighting and human performance ASHRAE Journal 4 6 2000 65 67 (Pubitemid 34798908)
-
(2002)
ASHRAE Journal
, vol.44
, Issue.6
, pp. 65-67
-
-
Heschong, L.1
-
25
-
-
20844434666
-
Summary of human responses to ventilation
-
DOI 10.1111/j.1600-0668.2004.00279.x
-
O. Seppänen, and W.J. Fisk Summary of human responses to ventilation Indoor Air 14 2004 102 118 (Pubitemid 39237235)
-
(2004)
Indoor Air, Supplement
, vol.14
, Issue.SUPPL. 7
, pp. 102-118
-
-
Seppanen, O.A.1
Fisk, W.J.2
-
28
-
-
34547869772
-
The effect of low ventilation rates on the cognitive function of a primary school class
-
D.A. Coley, R. Greeves, and B.K. Saxby The effect of low ventilation rates on the cognitive function of a primary school class International Journal of Ventilation 6 2 2007 107 112 (Pubitemid 47261740)
-
(2007)
International Journal of Ventilation
, vol.6
, Issue.2
, pp. 107-112
-
-
Coley, D.A.1
Greeves, R.2
Saxby, B.K.3
-
29
-
-
34247491290
-
Indoor environment in Dutch primary schools and health of the pupils
-
F.V. Dijken, J.V. Bronswijk, and J. Sundell Indoor environment in Dutch primary schools and health of the pupils Proceedings of the 10th International Conference on Indoor Air Quality and Climate, Indoor Air 2005 Beijing, vol. I, no. 1 2005 623 627
-
(2005)
Proceedings of the 10th International Conference on Indoor Air Quality and Climate, Indoor Air 2005 Beijing, Vol. I, No. 1
, pp. 623-627
-
-
Dijken, F.V.1
Bronswijk, J.V.2
Sundell, J.3
-
30
-
-
35449007326
-
Ventilation rates in schools
-
DOI 10.1016/j.buildenv.2006.03.018, PII S0360132306003568, Indoor Air 2005: Modeling, Assessment, and Control of Indoor Air Quality
-
D. Clements-Croome, H. Awbi, Z. Bako-Biro, N. Kochhar, and M. Williams Ventilation rates in schools Building and Environment 3 3 2008 362 367 (Pubitemid 47628365)
-
(2008)
Building and Environment
, vol.43
, Issue.3
, pp. 362-367
-
-
Clements-Croome, D.J.1
Awbi, H.B.2
Bako-Biro, Z.3
Kochhar, N.4
Williams, M.5
-
32
-
-
0742302453
-
Trade, the pollution haven hypothesis and the environmental Kuznets curve: Examining the linkages
-
DOI 10.1016/j.ecolecon.2003.09.007
-
M.A. Cole Trade, the pollution haven hypothesis and the environmental Kuznets curve: examining the linkages Ecological Economics 48 1 2004 71 81 (Pubitemid 38154127)
-
(2004)
Ecological Economics
, vol.48
, Issue.1
, pp. 71-81
-
-
Cole, M.A.1
-
36
-
-
84857064929
-
Healthy buildings-from science to practice, Plenary lecture in the International Conference of Healthy Buildings 2003
-
O. Seppänen Healthy buildings-from science to practice, Plenary lecture in the International Conference of Healthy Buildings 2003 Proceedings of Healthy Buildings Conference 2003
-
(2003)
Proceedings of Healthy Buildings Conference
-
-
Seppänen, O.1
-
37
-
-
84857057686
-
Standard 62-2004, Ventilation for Acceptable Indoor Air Quality, ANSI/ASHRAE Standard
-
ASHRAE 62 Inc., Atlanta, Georgia
-
ASHRAE 62. Standard 62-2004, Ventilation for Acceptable Indoor Air Quality, ANSI/ASHRAE Standard, American Society of Heating, Refrigerating, and Air Conditioning Engineers, Inc., Atlanta, Georgia, 2004.
-
(2004)
American Society of Heating, Refrigerating, and Air Conditioning Engineers
-
-
-
38
-
-
78649578040
-
Study on the productivity in the classroom (part 2): Realistic simulation experiment on effects of air quality/thermal environment on learning performance
-
K. Ito, S. Murakami, T. Kaneko, and H. Fukao Study on the productivity in the classroom (part 2): realistic simulation experiment on effects of air quality/thermal environment on learning performance Proceedings of Healthy Buildings Conference 2006 207 212
-
(2006)
Proceedings of Healthy Buildings Conference
, pp. 207-212
-
-
Ito, K.1
Murakami, S.2
Kaneko, T.3
Fukao, H.4
-
39
-
-
78649420931
-
Study on the productivity in the classroom (part 1) field survey of the effects of air quality/thermal environment on learning performance
-
S. Murakami, T. Kaneko, K. Ito, and H. Fukao Study on the productivity in the classroom (part 1) field survey of the effects of air quality/thermal environment on learning performance Proceedings of Healthy Buildings Conference 2006 271 276
-
(2006)
Proceedings of Healthy Buildings Conference
, pp. 271-276
-
-
Murakami, S.1
Kaneko, T.2
Ito, K.3
Fukao, H.4
-
40
-
-
33750388625
-
Effects of HVAC on student performance
-
P. Wargocki, and D. Wyon Research report on effects of HVAC on student performance ASHRAE Journal 8 10 2006 22 28 (Pubitemid 44637847)
-
(2006)
ASHRAE Journal
, vol.48
, Issue.10
, pp. 22-28
-
-
Wargocki, P.1
Wyon, D.P.2
-
41
-
-
34247513878
-
The effects of moderately raised classroom temperatures and classroom ventilation rate on the performance of schoolwork by children (RP-1257)
-
P. Wargocki, and D. Wyon The effect of moderately raised classroom temperatures and classroom ventilation rate on the performance of schoolwork by children HVAC&R Research 13 2 2007 193 220 (Pubitemid 46647647)
-
(2007)
HVAC and R Research
, vol.13
, Issue.2
, pp. 193-220
-
-
Wargocki, P.1
Wyon, D.P.2
-
42
-
-
34247520495
-
The effects of outdoor air supply rate and supply air filter condition in classrooms on the performance of schoolwork by children (RP-1257)
-
P. Wargocki, and D. Wyon The effects of outdoor air supply rate and supply air filter condition in classrooms on the performance of schoolwork by children (RP-1257) International Journal of Heating Ventilation Air Conditioning and Refrigerating Research 3 2 2007 165 191 (Pubitemid 46647646)
-
(2007)
HVAC and R Research
, vol.13
, Issue.2
, pp. 165-191
-
-
Wargocki, P.1
Wyon, D.P.2
-
43
-
-
80052939914
-
Ventilation rates in schools and learning performance
-
Z. Bakó-Biró, N. Kochhar, D. Clements-Croome, H. Awbi, and M. Williams Ventilation rates in schools and learning performance Proceedings of Clima 2007 10 14
-
(2007)
Proceedings of Clima
, pp. 10-14
-
-
Bakó-Biró, Z.1
Kochhar, N.2
Clements-Croome, D.3
Awbi, H.4
Williams, M.5
-
44
-
-
80052165702
-
-
MD meteorological department, directorate of civil aviation. Kuwait
-
MD, The Metrological Department annual report, meteorological department, directorate of civil aviation. Kuwait, 2004.
-
(2004)
The Metrological Department Annual Report
-
-
-
46
-
-
2442589951
-
Carbon dioxide levels and dynamics in elementary schools: Results of the TESIAS study
-
R. Corsi, V. Torres, M. Sanders, and K. Kinney Carbon dioxide levels and dynamics in elementary schools: results of the TESIAS study Indoor Air 2 2002 74 79
-
(2002)
Indoor Air
, vol.2
, pp. 74-79
-
-
Corsi, R.1
Torres, V.2
Sanders, M.3
Kinney, K.4
-
47
-
-
0036016454
-
Inter-comparison of air pollutant concentrations in different indoor environments in Hong Kong
-
DOI 10.1016/S1352-2310(02)00176-0, PII S1352231002001760
-
S.C. Lee, H. Guo, W.M. Li, and L.Y. Chan Inter-comparison of air pollutant concentrations in different indoor environments in Hong Kong Atmospheric Environment 36 2002 1929 1940 (Pubitemid 34632584)
-
(2002)
Atmospheric Environment
, vol.36
, Issue.12
, pp. 1929-1940
-
-
Lee, S.-C.1
Guo, H.2
Li, W.-M.3
Chan, L.-Y.4
-
49
-
-
17644387556
-
Comparative study of the indoor air quality of naturally ventilated and air-conditioned bedrooms of residential buildings in Singapore
-
DOI 10.1016/j.buildenv.2004.01.024, PII S0360132304000356
-
N.H. Wong, and B. Huang Comparative study of the indoor air quality of naturally ventilated and air-conditioned bedrooms of residential buildings in Singapore Building and Environment 9 9 2004 1115 1123 (Pubitemid 40564040)
-
(2004)
Building and Environment
, vol.39
, Issue.9
, pp. 1115-1123
-
-
Wong, N.H.1
Huang, B.2
-
50
-
-
1542742113
-
Enhancement of ventilation performance of a residential split-system air-conditioning unit
-
S. Sekhar Enhancement of ventilation performance of a residential split-system air-conditioning unit Energy and Buildings 6 3 2004 273 279
-
(2004)
Energy and Buildings
, vol.6
, Issue.3
, pp. 273-279
-
-
Sekhar, S.1
-
52
-
-
84938860869
-
Investigating the applicability of different thermal comfort models in air-conditioned classrooms in Kuwait
-
Antalya, Turkey ISBN: 978-975-6907-14-6
-
K.E. Al-Rashidi, D.L. Loveday, and N.K. Al-Mutawa Investigating the applicability of different thermal comfort models in air-conditioned classrooms in Kuwait Proceedings of the 10th REHVA World Congress, Sustainable Energy use in Building, Clima 2010 Antalya, Turkey 2010 ISBN: 978-975-6907-14-6
-
(2010)
Proceedings of the 10th REHVA World Congress, Sustainable Energy Use in Building, Clima 2010
-
-
Al-Rashidi, K.E.1
Loveday, D.L.2
Al-Mutawa, N.K.3
|