메뉴 건너뛰기




Volumn 30, Issue 3, 2012, Pages 530-536

Rectangular cuffs may overestimate blood pressure in individuals with large conical arms

Author keywords

arm size; bladder; blood pressure; conical; cuff; measurement

Indexed keywords

ARM CIRCUMFERENCE; BLOOD PRESSURE CUFF; BLOOD PRESSURE MEASUREMENT; CONFERENCE PAPER; FEMALE; HUMAN; MALE; MEASUREMENT ERROR; OBESITY; PRIORITY JOURNAL;

EID: 84857048251     PISSN: 02636352     EISSN: 14735598     Source Type: Journal    
DOI: 10.1097/HJH.0b013e32834f98a0     Document Type: Conference Paper
Times cited : (46)

References (15)
  • 2
    • 0020061643 scopus 로고
    • Reliability of blood-pressure measurement on fat upper-arms
    • Huige MC. Reliability of blood pressure measurement on fat upper arms. Ther Umsch 1982; 39:87-91. (Pubitemid 12183945)
    • (1982) Therapeutische Umschau , vol.39 , Issue.2 , pp. 87-91
    • Huige, M.C.1
  • 3
    • 79951662140 scopus 로고    scopus 로고
    • Blood pressure measurement in very obese patients: A challenging problem
    • Palatini P, Parati G. Blood pressure measurement in very obese patients: a challenging problem. J Hypertens 2011; 29:425-429.
    • (2011) J Hypertens , vol.29 , pp. 425-429
    • Palatini, P.1    Parati, G.2
  • 4
    • 0037048669 scopus 로고    scopus 로고
    • Prevalence and trends in obesity among US adults, 1999-2000
    • Flegal KM, Carroll MD, Ogden CL, Johnson CL. Prevalence and trends in obesity among US adults, 1999-2000. JAMA 2002; 288:1723-1727.
    • (2002) JAMA , vol.288 , pp. 1723-1727
    • Flegal, K.M.1    Carroll, M.D.2    Ogden, C.L.3    Johnson, C.L.4
  • 5
    • 3042735707 scopus 로고    scopus 로고
    • The changing distribution of arm circumferences in NHANES III and NHANES 2000 and its impact on the utility of the 'standard adult' blood pressure cuff
    • DOI 10.1097/00126097-20031200000001
    • Graves JW, Bailey KR, Sheps SG. The changing distribution of arm circumferences in NHANES III and NHANES 2000 and its impact on the utility of the 'standard adult' blood pressure cuff. Blood Press Monit 2003; 8:223-227. (Pubitemid 39089943)
    • (2003) Blood Pressure Monitoring , vol.8 , Issue.6 , pp. 223-227
    • Graves, J.W.1    Bailey, K.R.2    Sheps, S.G.3
  • 6
    • 78149341709 scopus 로고    scopus 로고
    • Accuracy of a single rigid conical cuff with standard-size bladder coupled to an automatic oscillometric device over a wide range of arm circumferences
    • Bonso E, Saladini F, Zanier A, Benetti E, Dorigatti F, Palatini P. Accuracy of a single rigid conical cuff with standard-size bladder coupled to an automatic oscillometric device over a wide range of arm circumferences. Hypertens Res 2010; 33:1186-1191.
    • (2010) Hypertens Res , vol.33 , pp. 1186-1191
    • Bonso, E.1    Saladini, F.2    Zanier, A.3    Benetti, E.4    Dorigatti, F.5    Palatini, P.6
  • 7
    • 13444255966 scopus 로고    scopus 로고
    • Recommendations for blood pressure measurement in humans and experimental animals: Part 1: Blood pressure measurement in humans - A statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on high blood pressure research
    • DOI 10.1161/01.CIR.0000154900.76284.F6
    • Pickering TG, Hall JE, Appel LJ, Falkner BE, Graves J, Hill MN, et al. Recommendations for blood pressure measurement in humans and experimental animals. Part 1. Blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research. Circulation 2005; 111:697-716. (Pubitemid 40216499)
    • (2005) Circulation , vol.111 , Issue.5 , pp. 697-716
    • Pickering, T.G.1    Hall, J.E.2    Appel, L.J.3    Falkner, B.E.4    Graves, J.5    Hill, M.N.6    Jones, D.W.7    Kurtz, T.8    Sheps, S.G.9    Roccella, E.J.10
  • 8
    • 0035992025 scopus 로고    scopus 로고
    • Working Group on Blood Pressure Monitoring of the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adults
    • DOI 10.1097/00126097-20020200000002
    • O'Brien E, Pickering T, Asmar R, Myers M, Parati G, Staessen J, et al. Working Group on Blood Pressure Monitoring of the European Society of Hypertension. European Society of Hypertension International protocol for validation of blood pressure measuring devices in adults. Blood Press Monit 2002; 7:3-17. (Pubitemid 34304045)
    • (2002) Blood Pressure Monitoring , vol.7 , Issue.1 , pp. 3-17
    • O'Brien, E.1    Pickering, T.2    Asmar, R.3    Myers, M.4    Parati, G.5    Staessen, J.6    Mengden, T.7    Imai, Y.8    Waeber, B.9    Palatini, P.10    Gerin, W.11
  • 9
    • 77957574532 scopus 로고    scopus 로고
    • Accuracy of the visomat handy wrist blood pressure measuring device according to the International Protocol
    • Saladini F, Benetti E, Palatini P. Accuracy of the visomat handy wrist blood pressure measuring device according to the International Protocol. Blood Press Monit 2010; 15:281-284.
    • (2010) Blood Press Monit , vol.15 , pp. 281-284
    • Saladini, F.1    Benetti, E.2    Palatini, P.3
  • 10
    • 82755193753 scopus 로고    scopus 로고
    • Effect of tissue mechanical properties on cuff-based blood pressure measurements
    • Lan H, Al-Jumaily AM, Lowe A, Hing W. Effect of tissue mechanical properties on cuff-based blood pressure measurements. Med Eng Phys 2011; 33:1287-1292.
    • (2011) Med Eng Phys , vol.33 , pp. 1287-1292
    • Lan, H.1    Al-Jumaily, A.M.2    Lowe, A.3    Hing, W.4
  • 11
    • 0029831681 scopus 로고    scopus 로고
    • Review: A century of confusion; which bladder for accurate blood pressure measurement?
    • O'Brien E. Review: a century of confusion; which bladder for accurate blood pressure measurement? J Hum Hypertens 1996; 10:565-572. (Pubitemid 26402311)
    • (1996) Journal of Human Hypertension , vol.10 , Issue.9 , pp. 565-572
    • O'Brien, E.1
  • 13
    • 79951659479 scopus 로고    scopus 로고
    • What to do when faced with an unmeasurable ambulatory blood pressure?
    • O'Brien E. What to do when faced with an unmeasurable ambulatory blood pressure? J Hypertens 2011; 29:451-453.
    • (2011) J Hypertens , vol.29 , pp. 451-453
    • O'Brien, E.1
  • 14
    • 79957944591 scopus 로고    scopus 로고
    • Postanesthesia patients with large upper arm circumference: Is use of an 'extra-long' adult cuff or forearm cuff placement accurate?
    • Watson S, Aguas M, Bienapfl T, Colegrove P, Foisy N, Jondahl B, et al. Postanesthesia patients with large upper arm circumference: is use of an 'extra-long' adult cuff or forearm cuff placement accurate? J Perianesth Nurs 2011; 26:135-142.
    • (2011) J Perianesth Nurs , vol.26 , pp. 135-142
    • Watson, S.1    Aguas, M.2    Bienapfl, T.3    Colegrove, P.4    Foisy, N.5    Jondahl, B.6
  • 15
    • 27844551933 scopus 로고    scopus 로고
    • US demographic trends in mid-arm circumference and recommended blood pressure cuffs: 1988-2002
    • DOI 10.1038/sj.jhh.1001905, PII 1001905
    • Ostchega Y, Dillon C, Carroll M, Prineas RJ, McDowell M. US demographic trends in mid-arm circumference and recommended blood pressure cuffs: 1988-2002. J Hum Hypertens 2005; 19:885-891. (Pubitemid 41637605)
    • (2005) Journal of Human Hypertension , vol.19 , Issue.11 , pp. 885-891
    • Ostchega, Y.1    Dillon, C.2    Carroll, M.3    Prineas, R.J.4    McDowell, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.