메뉴 건너뛰기




Volumn 47, Issue , 2012, Pages 411-420

Validation of a numerical model aimed at the estimation of performance of vapor compression based heat pumps

Author keywords

Chiller; COP; Energy; Heat pump; Secondary fluid temperature

Indexed keywords

CHILLER; COP; ENERGY; HEAT PUMPS; SECONDARY FLUIDS;

EID: 84857044065     PISSN: 03787788     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enbuild.2011.12.011     Document Type: Article
Times cited : (30)

References (17)
  • 1
    • 0000625135 scopus 로고
    • A simulation program for modeling an air-conditioning system
    • J. Hamilton, and J. Miller A simulation program for modeling an air-conditioning system ASHRAE Transactions 96 1 1990 213 221
    • (1990) ASHRAE Transactions , vol.96 , Issue.1 , pp. 213-221
    • Hamilton, J.1    Miller, J.2
  • 3
    • 84857043864 scopus 로고
    • M.S. Thesis, Department of Mechanical Engineering, University of Illinois, Urbana-Champaign
    • T. Lash, Simulation and analysis of a water loop heat pump system, M.S. Thesis, Department of Mechanical Engineering, University of Illinois, Urbana-Champaign, 1992.
    • (1992) Simulation and Analysis of A Water Loop Heat Pump System
    • Lash, T.1
  • 4
  • 7
    • 0003959633 scopus 로고
    • The Oak Ridge heat pump models - 1 - A steady-state computer design model for air-to-air heat pumps
    • Oak Ridge, TN
    • S. Fischer, C. Rice, The Oak Ridge heat pump models - 1 - a steady-state computer design model for air-to-air heat pumps, Report ORNL/CON-80/R1, Oak Ridge National Laboratory, Oak Ridge, TN, 1983.
    • (1983) Report ORNL/CON-80/R1, Oak Ridge National Laboratory
    • Fischer, S.1    Rice, C.2
  • 8
    • 0021462070 scopus 로고
    • Mathematical model of an air-to-air heat pump equipped with a capillary tube
    • P. Domanski, and D. Didion Mathematical model of an air-to-air heat pump equipped with a capillary tube International Journal of Refrigeration 7 4 1984 249 255
    • (1984) International Journal of Refrigeration , vol.7 , Issue.4 , pp. 249-255
    • Domanski, P.1    Didion, D.2
  • 9
    • 0000527144 scopus 로고
    • A simulation model of refrigerant and air-conditioning equipment based on experimental data
    • C. Cecchini, and D. Marchal A simulation model of refrigerant and air-conditioning equipment based on experimental data ASHRAE Transactions 97 2 1991 388 393
    • (1991) ASHRAE Transactions , vol.97 , Issue.2 , pp. 388-393
    • Cecchini, C.1    Marchal, D.2
  • 10
    • 0027003047 scopus 로고
    • Modeling and simulation of a superheat-controlled water-to-water heat pump
    • N. Stefanuk, J. Aplevich, and M. Renksizbulut Modeling and simulations of a superheat-controlled water-to-water heat pump ASHRAE Transactions 98 2 1992 172 184 (Pubitemid 23667756)
    • (1992) ASHRAE Transactions , vol.98 , Issue.PART 2 , pp. 172-184
    • Stefanuk, N.B.M.1    Aplevich, J.D.2    Renksizbulut, M.3
  • 11
    • 0028722291 scopus 로고
    • A toolkit for primary HVAC system energy calculation - Part 2: Reciprocating chiller models
    • J.P.H. Bourdouxhe, M. Grodent, J. Lebrun, C. Saavedra, and K. Silva A toolkit for primary HVAC system energy calculation - part 2: reciprocating chiller models ASHRAE Transactions 100 2 1994 774 786
    • (1994) ASHRAE Transactions , vol.100 , Issue.2 , pp. 774-786
    • Bourdouxhe, J.P.H.1    Grodent, M.2    Lebrun, J.3    Saavedra, C.4    Silva, K.5
  • 12
    • 17544392169 scopus 로고    scopus 로고
    • A parameter estimation based model of water-to-water heat pumps for use in energy calculation programs
    • H. Jin, and J. Spitler A parameter estimation based model of water-to-water heat pumps for use in energy calculation programs ASHRAE Transactions 108 1 2002 3 17 (Pubitemid 34613650)
    • (2002) ASHRAE Transactions , vol.108 PART 1 , pp. 3-17
    • Jin, H.1    Spitler, J.D.2
  • 13
    • 0025546388 scopus 로고
    • Comparison of three steady-state heat pump computer models
    • G. Damasceno, V. Goldschmidt, and S. Rooke Comparison of three steady-state heat pump computer models ASHRAE Transactions 96 2 1990 191 204
    • (1990) ASHRAE Transactions , vol.96 , Issue.2 , pp. 191-204
    • Damasceno, G.1    Goldschmidt, V.2    Rooke, S.3
  • 15
    • 84857044010 scopus 로고    scopus 로고
    • EN 14511-2:2007 - Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling
    • EN 14511-2:2007 - air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling. Test conditions.
    • Test Conditions
  • 16
    • 84857044158 scopus 로고    scopus 로고
    • EN 14511-3:2007 - Air conditioners, liquid chilling packages and heat pumps with electrical driven compressors for space heating and cooling
    • EN 14511-3:2007 - air conditioners, liquid chilling packages and heat pumps with electrical driven compressors for space heating and cooling. Test methods.
    • Test Methods
  • 17
    • 84857042325 scopus 로고    scopus 로고
    • EN 14511-4:2007 - Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling
    • EN 14511-4:2007 - air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling. Requirements.
    • Requirements


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.