메뉴 건너뛰기




Volumn 33, Issue 2, 2012, Pages 130-136

Comparing the finapres and caretaker systems for measuring pulse transit time before and after exercise

Author keywords

blood pressure device; exercise; haemorrhage device; sensitivity; vascular stiffness

Indexed keywords

ADULT; ARTICLE; BLOOD PRESSURE; BLOOD PRESSURE MEASUREMENT; COMPARATIVE STUDY; ENDURANCE; EQUIPMENT DESIGN; EXERCISE; FEMALE; HEART RATE; HUMAN; MALE; METHODOLOGY; MIDDLE AGED; PHYSIOLOGY; PULSE RATE; TIME;

EID: 84857030616     PISSN: 01724622     EISSN: 14393964     Source Type: Journal    
DOI: 10.1055/s-0031-1291185     Document Type: Article
Times cited : (3)

References (31)
  • 2
    • 0036813658 scopus 로고    scopus 로고
    • Age-related changes in peripheral pulse timing characteristics at the ears, fingers and toes
    • DOI 10.1038/sj.jhh.1001478
    • Allen J, Murray A. Age-related changes in peripheral pulse timing characteristics at the ears, fingers and toes. J Hum Hypertens: 2002; 16 711 717 (Pubitemid 35396505)
    • (2002) Journal of Human Hypertension , vol.16 , Issue.10 , pp. 711-717
    • Allen, J.1    Murray, A.2
  • 3
    • 0035069107 scopus 로고    scopus 로고
    • Pulse wave velocity as endpoint in large-scale intervention trial. The complior® study
    • DOI 10.1097/00004872-200104000-00019
    • Asmar R, Topouchian J, Pannier B, Benetos A, Safar M. Pulse wave velocity as endpoint in large-scale intervention trial. The Complior Study. Scientific, Quality Control, Coordination and Investigation Committees of the Complior Study. J Hypertens: 2001; 19 813 818 (Pubitemid 32289562)
    • (2001) Journal of Hypertension , vol.19 , Issue.4 , pp. 813-818
    • Asmar, R.1    Topouchian, J.2    Pannier, B.3    Benetos, A.4    Safar, M.5
  • 5
    • 0028987325 scopus 로고
    • Elastic properties and Windkessel function of the human aorta
    • Belz G G. Elastic properties and Windkessel function of the human aorta. Cardiovasc Drugs Ther: 1995; 9 73 83
    • (1995) Cardiovasc Drugs Ther , vol.9 , pp. 73-83
    • Belz, G.G.1
  • 6
    • 34548642652 scopus 로고    scopus 로고
    • Change in pulse transit time and pre-ejection period during head-up tilt-induced progressive central hypovolaemia
    • DOI 10.1007/s10877-007-9086-8
    • Chan G S, Middleton P M, Celler B G, Wang L, Lovell N H. Change in pulse transit time and pre-ejection period during head-up tilt-induced progressive central hypovolaemia. J Clin Monit Comput: 2007; 21 283 293 (Pubitemid 47399694)
    • (2007) Journal of Clinical Monitoring and Computing , vol.21 , Issue.5 , pp. 283-293
    • Chan, G.S.H.1    Middleton, P.M.2    Celler, B.G.3    Wang, L.4    Lovell, N.H.5
  • 7
    • 0015142921 scopus 로고
    • Pulse wave velocity in healthy subjects and in patients with various disease states
    • Eliakim M, Sapoznikov D, Weinman J. Pulse wave velocity in healthy subjects and in patients with various disease states. Am Heart J: 1971; 82 448 457
    • (1971) Am Heart J , vol.82 , pp. 448-457
    • Eliakim, M.1    Sapoznikov, D.2    Weinman, J.3
  • 8
    • 18844407256 scopus 로고    scopus 로고
    • Repeatability of non-invasive measurement of intracerebral pulse wave velocity using transcranial Doppler
    • DOI 10.1042/CS20040251
    • Gladdish S, Manawadu D, Banya W, Cameron J, Bulpitt C J, Rajkumar C. Repeatability of non-invasive measurement of intracerebral pulse wave velocity using transcranial Doppler. Clin Sci (Lond): 2005; 108 433 439 (Pubitemid 40685673)
    • (2005) Clinical Science , vol.108 , Issue.5 , pp. 433-439
    • Gladdish, S.1    Manawadu, D.2    Banya, W.3    Cameron, J.4    Bulpitt, C.J.5    Rajkumar, C.6
  • 9
    • 80855138754 scopus 로고    scopus 로고
    • Update - Ethical Standards in Sport and Exercise Science Research
    • Harriss D J, Atkinson G. Update - Ethical Standards in Sport and Exercise Science Research. Int J Sports Med: 2011; 32 819 821
    • (2011) Int J Sports Med , vol.32 , pp. 819-821
    • Harriss, D.J.1    Atkinson, G.2
  • 11
    • 73849150936 scopus 로고    scopus 로고
    • Validity and repeatability of the Vicorder apparatus: A comparison with the SphygmoCor device
    • Hickson S S, Butlin M, Broad J, Avolio A P, Wilkinson I B, McEniery C M. Validity and repeatability of the Vicorder apparatus: a comparison with the SphygmoCor device. Hypertens Res: 2009; 32 1079 1085
    • (2009) Hypertens Res , vol.32 , pp. 1079-1085
    • Hickson, S.S.1    Butlin, M.2    Broad, J.3    Avolio, A.P.4    Wilkinson, I.B.5    McEniery, C.M.6
  • 12
    • 0032102644 scopus 로고    scopus 로고
    • Fifteen years experience with finger arterial pressure monitoring: Assessment of the technology
    • DOI 10.1016/S0008-6363(98)00067-4, PII S0008636398000674
    • Imholz B P, Wieling W, van Montfrans G A, Wesseling K H. Fifteen years experience with finger arterial pressure monitoring: assessment of the technology. Cardiovasc Res: 1998; 38 605 616 (Pubitemid 28319870)
    • (1998) Cardiovascular Research , vol.38 , Issue.3 , pp. 605-616
    • Imholz, B.P.M.1    Wieling, W.2    Van Montfrans, G.A.3    Wesseling, K.H.4
  • 13
    • 0028875702 scopus 로고
    • Pressure wave propagation in a multibranched model of the human upper limb
    • Karamanoglu M, Gallagher D E, Avolio A P, ORourke M F. Pressure wave propagation in a multibranched model of the human upper limb. Am J Physiol: 1995; 269 H1363 H1369
    • (1995) Am J Physiol , vol.269
    • Karamanoglu, M.1    Gallagher, D.E.2    Avolio, A.P.3    Orourke, M.F.4
  • 14
    • 0029926262 scopus 로고    scopus 로고
    • Adverse influence of systemic vascular stiffening on cardiac dysfunction and adaptation to acute coronary occlusion
    • Kass D A, Saeki A, Tunin R S, Recchia F A. Adverse influence of systemic vascular stiffening on cardiac dysfunction and adaptation to acute coronary occlusion. Circulation: 1996; 93 1533 1541 (Pubitemid 26115419)
    • (1996) Circulation , vol.93 , Issue.8 , pp. 1533-1541
    • Kass, D.A.1    Saeki, A.2    Tunin, R.S.3    Recchia, F.A.4
  • 16
    • 33747604175 scopus 로고    scopus 로고
    • Validation of a new index for estimating arterial stiffness: Measurement of the QPV interval by Doppler ultrasound
    • Lee M Y, Chu C S, Lee K T, Wu C M, Su H M, Lin S J, Sheu S H, Lai W T. Validation of a new index for estimating arterial stiffness: measurement of the QPV interval by Doppler ultrasound. Clin Cardiol: 2006; 29 345 351
    • (2006) Clin Cardiol , vol.29 , pp. 345-351
    • Lee, M.Y.1    Chu, C.S.2    Lee, K.T.3    Wu, C.M.4    Su, H.M.5    Lin, S.J.6    Sheu, S.H.7    Lai, W.T.8
  • 17
    • 84856210623 scopus 로고    scopus 로고
    • Measuring pulse wave velocity using ECG and photoplethysmography
    • Epub ahead of print 10.1007/s10916-010-9469-0
    • Liu A B, Hsu P C, Chen Z L, Wu H T. Measuring pulse wave velocity using ECG and photoplethysmography. J Med Syst: 2010; Epub ahead of print 10.1007/s10916-010-9469-0
    • (2010) J Med Syst
    • Liu, A.B.1    Hsu, P.C.2    Chen, Z.L.3    Wu, H.T.4
  • 19
    • 0041317016 scopus 로고    scopus 로고
    • Piezoelectric sensor determination of arterial pulse wave velocity
    • DOI 10.1088/0967-3334/24/3/306, PII S096733340358306X
    • McLaughlin J, McNeill M, Braun B, McCormack P D. Piezoelectric sensor determination of arterial pulse wave velocity. Physiol Meas: 2003; 24 693 702 (Pubitemid 37081822)
    • (2003) Physiological Measurement , vol.24 , Issue.3 , pp. 693-702
    • McLaughlin, J.1    McNeill, M.2    Braun, B.3    McCormack, P.D.4
  • 20
    • 63349094938 scopus 로고    scopus 로고
    • Changes in left ventricular ejection time and pulse transit time derived from finger photoplethysmogram and electrocardiogram during moderate haemorrhage
    • Middleton P M, Chan G S, O'Lone E, Steel E, Carroll R, Celler B G, Lovell N H. Changes in left ventricular ejection time and pulse transit time derived from finger photoplethysmogram and electrocardiogram during moderate haemorrhage. Clin Physiol Funct Imaging: 2009; 29 163 169
    • (2009) Clin Physiol Funct Imaging , vol.29 , pp. 163-169
    • Middleton, P.M.1    Chan, G.S.2    O'Lone, E.3    Steel, E.4    Carroll, R.5    Celler, B.G.6    Lovell, N.H.7
  • 23
    • 0036174280 scopus 로고    scopus 로고
    • The difference in pulse transit time to the toe and finger measured by photoplethysmography
    • DOI 10.1088/0967-3334/23/1/308, PII S096733340225354X
    • Nitzan M, Khanokh B, Slovik Y. The difference in pulse transit time to the toe and finger measured by photoplethysmography. Physiol Meas: 2002; 23 85 93 (Pubitemid 34155068)
    • (2002) Physiological Measurement , vol.23 , Issue.1 , pp. 85-93
    • Nitzan, M.1    Khanokh, B.2    Slovik, Y.3
  • 26
    • 33745445589 scopus 로고    scopus 로고
    • Global versus local linear beat-to-beat analysis of the relationship between arterial pressure and pulse transit time during dynamic exercise
    • DOI 10.1007/s11517-006-0042-4
    • Porta A, Gasperi C, Nollo G, Lucini D, Pizzinelli P, Antolini R, Pagani M. Global versus local linear beat-to-beat analysis of the relationship between arterial pressure and pulse transit time during dynamic exercise. Med Biol Eng Comput: 2006; 44 331 337 (Pubitemid 43949708)
    • (2006) Medical and Biological Engineering and Computing , vol.44 , Issue.4 , pp. 331-337
    • Porta, A.1    Gasperi, C.2    Nollo, G.3    Lucini, D.4    Pizzinelli, P.5    Antolini, R.6    Pagani, M.7
  • 27
    • 59649128324 scopus 로고    scopus 로고
    • Effect of acute sprint interval exercise on central and peripheral artery distensibility in young healthy males
    • Rakobowchuk M, Stuckey M I, Millar P J, Gurr L, Macdonald M J. Effect of acute sprint interval exercise on central and peripheral artery distensibility in young healthy males. Eur J Appl Physiol: 2009; 105 787 795
    • (2009) Eur J Appl Physiol , vol.105 , pp. 787-795
    • Rakobowchuk, M.1    Stuckey, M.I.2    Millar, P.J.3    Gurr, L.4    MacDonald, M.J.5
  • 28
    • 77950860664 scopus 로고    scopus 로고
    • Intermittent versus constant aerobic exercise: Effects on arterial stiffness
    • Tordi N, Mourot L, Colin E, Regnard J. Intermittent versus constant aerobic exercise: effects on arterial stiffness. Eur J Appl Physiol: 2010; 108 801 809
    • (2010) Eur J Appl Physiol , vol.108 , pp. 801-809
    • Tordi, N.1    Mourot, L.2    Colin, E.3    Regnard, J.4
  • 30
    • 0010488709 scopus 로고
    • Century of noninvasive arterial pressure measurement: From Marey to Penaz and Finapres
    • Wesseling K H. Century of noninvasive arterial pressure measurement: from Marey to Penaz and Finapres. Homeostasis Hlth Dis: 1995; 36 50 66
    • (1995) Homeostasis Hlth Dis , vol.36 , pp. 50-66
    • Wesseling, K.H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.