-
1
-
-
0035341497
-
Organ motion and its management
-
10.1016/S0360-3016(01)01453-5
-
K. M. Langen, and D. T. L. Jones, Organ motion and its management., Int. J. Radiat. Oncol., Biol., Phys. 50 (1), 265-278 (2001). 10.1016/S0360-3016(01) 01453-5
-
(2001)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.50
, Issue.1
, pp. 265-278
-
-
Langen, K.M.1
Jones, D.T.L.2
-
2
-
-
0344826552
-
Alterations in normal liver doses due to organ motion
-
10.1016/j.ijrob2003.08.025
-
M. Rosu, L. A. Dawson, J. M. Balter, D. L. McShan, T. S. Lawrence, and R. K. T. Haken, Alterations in normal liver doses due to organ motion., Int. J. Radiat. Oncol., Biol., Phys. 57 (5), 1472-1479 (2003). 10.1016/j.ijrobp.2003.08. 025
-
(2003)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.57
, Issue.5
, pp. 1472-1479
-
-
Rosu, M.1
Dawson, L.A.2
Balter, J.M.3
McShan, D.L.4
Lawrence, T.S.5
Haken, R.K.T.6
-
3
-
-
62649095379
-
Potential dosimetric benefits of four-dimensional radiation treatment planning
-
10.1016/j.ijrob2008.12.024
-
G. Starkschall, K. Britton, M. F. McAleer, M. D. Jeter, M. R. Kaus, K. Bzdusek, R. Mohan, and J. D. Cox, Potential dosimetric benefits of four-dimensional radiation treatment planning., Int. J. Radiat. Oncol., Biol., Phys. 73 (5), 1560-1565 (2009). 10.1016/j.ijrobp.2008.12.024
-
(2009)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.73
, Issue.5
, pp. 1560-1565
-
-
Starkschall, G.1
Britton, K.2
McAleer, M.F.3
Jeter, M.D.4
Kaus, M.R.5
Bzdusek, K.6
Mohan, R.7
Cox, J.D.8
-
4
-
-
65449164698
-
Cumulative lung dose for several motion management strategies as a function of pretreatment patient parameters
-
10.1016/j.ijrob2008.12.069
-
G. D. Hugo, J. Campbell, T. Zhang, and D. Yan, Cumulative lung dose for several motion management strategies as a function of pretreatment patient parameters., Int. J. Radiat. Oncol., Biol., Phys. 74 (2), 593-601 (2009). 10.1016/j.ijrobp.2008.12.069
-
(2009)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.74
, Issue.2
, pp. 593-601
-
-
Hugo, G.D.1
Campbell, J.2
Zhang, T.3
Yan, D.4
-
5
-
-
49749100424
-
Clinical experience using hypofractionated radiation schedules in breast cancer
-
10.1016/j.semradonc.2008.04.008
-
T. J. Whelan, D. H. Kim, and J. Sussman, Clinical experience using hypofractionated radiation schedules in breast cancer., Semin. Radiat. Oncol. 18 (4), 257-264 (2008). 10.1016/j.semradonc.2008.04.008
-
(2008)
Semin. Radiat. Oncol.
, vol.18
, Issue.4
, pp. 257-264
-
-
Whelan, T.J.1
Kim, D.H.2
Sussman, J.3
-
6
-
-
0035667972
-
Stereotactic radiotherapy of targets in the lung and liver
-
10.1007/PL00002379
-
J. Wulf, U. Hadinger, U. Oppitz, W. Thiele, R. Ness-Dourdoumas, and M. Flentje, Stereotactic radiotherapy of targets in the lung and liver., Strahlenther Onkol. 177 (12), 645-655 (2001). 10.1007/PL00002379
-
(2001)
Strahlenther Onkol.
, vol.177
, Issue.12
, pp. 645-655
-
-
Wulf, J.1
Hadinger, U.2
Oppitz, U.3
Thiele, W.4
Ness-Dourdoumas, R.5
Flentje, M.6
-
7
-
-
70350623229
-
Monte Carlo dose mapping on deforming anatomy
-
10.1088/0031-9155/54/19/010
-
H. Zhong, and J. V. Slebers, Monte Carlo dose mapping on deforming anatomy., Phys. Med. Biol. 54 (19), 5815-5830 (2009). 10.1088/0031-9155/54/19/ 010
-
(2009)
Phys. Med. Biol.
, vol.54
, Issue.19
, pp. 5815-5830
-
-
Zhong, H.1
Slebers, J.V.2
-
8
-
-
33744804817
-
Estimation of the delivered patient dose in lung IMRT treatment based on deformable registration of 4D-CT data and Monte Carlo simulations
-
10.1088/0031-9155/51/11/006
-
S. Flampouri, S. B. Jiang, G. C. Sharp, J. Wolfgang, A. A. Patel, and N. C. Choi, Estimation of the delivered patient dose in lung IMRT treatment based on deformable registration of 4D-CT data and Monte Carlo simulations., Phys. Med. Biol. 51 (11), 2763-2779 (2006). 10.1088/0031-9155/51/11/006
-
(2006)
Phys. Med. Biol.
, vol.51
, Issue.11
, pp. 2763-2779
-
-
Flampouri, S.1
Jiang, S.B.2
Sharp, G.C.3
Wolfgang, J.4
Patel, A.A.5
Choi, N.C.6
-
9
-
-
51049123184
-
Improving image-guided target localization through deformable registration
-
10.1080/02841860802256491
-
K. K. Brock, M. Hawkins, C. Eccles, J. L. Moseley, D. J. Moseley, D. A. Jaffray, and L. A. Dawson, Improving image-guided target localization through deformable registration., Acta Oncol. 47 (7), 1279-1285 (2008). 10.1080/02841860802256491
-
(2008)
Acta Oncol.
, vol.47
, Issue.7
, pp. 1279-1285
-
-
Brock, K.K.1
Hawkins, M.2
Eccles, C.3
Moseley, J.L.4
Moseley, D.J.5
Jaffray, D.A.6
Dawson, L.A.7
-
10
-
-
0037342615
-
Inclusion of organ deformation in dose calculations
-
10.1118/1.1539039
-
K. K. Brock, S. J. Hollister, L. A. Dawson, and J. M. Balter, Inclusion of organ deformation in dose calculations., Med. Phys. 30 (3), 290-295 (2003). 10.1118/1.1539039
-
(2003)
Med. Phys.
, vol.30
, Issue.3
, pp. 290-295
-
-
Brock, K.K.1
Hollister, S.J.2
Dawson, L.A.3
Balter, J.M.4
-
11
-
-
21144441919
-
Accuracy of finite element model (FEM)-based multi-organ deformable image registration
-
10.1118/1.1915012
-
K. K. Brock, M. B. Sharpe, S. M. Kim, and D. A. Jaffray, Accuracy of finite element model (FEM)-based multi-organ deformable image registration., Med. Phys. 32 (6), 1647-1659 (2005). 10.1118/1.1915012
-
(2005)
Med. Phys.
, vol.32
, Issue.6
, pp. 1647-1659
-
-
Brock, K.K.1
Sharpe, M.B.2
Kim, S.M.3
Jaffray, D.A.4
-
12
-
-
58149288142
-
Verification of dynamic radiotherapy: The potential for 3D dosimetry under respiratory-like motion using polymer gel
-
10.1088/0031-9155/53/20/N02
-
S. Ceberg, A. Karlsson, H. Gustavsson, L. Wittgren, and S. J. Bäck, Verification of dynamic radiotherapy: the potential for 3D dosimetry under respiratory-like motion using polymer gel., Phys. Med. Biol. 53, N387-N396 (2008). 10.1088/0031-9155/53/20/N02
-
(2008)
Phys. Med. Biol.
, vol.53
-
-
Ceberg, S.1
Karlsson, A.2
Gustavsson, H.3
Wittgren, L.4
Bäck, S.J.5
-
13
-
-
58149242696
-
Experimental measurements and Monte Carlo simulations for dosimetric evaluations of intrafraction motion for gated and ungated intensity modulated arc therapy deliveries
-
10.1088/0031-9155/53/22/010
-
M. Oliver, A. Gladwish, R. Staruch, J. Craig, S. Gaede, J. Chen, and E. Wong, Experimental measurements and Monte Carlo simulations for dosimetric evaluations of intrafraction motion for gated and ungated intensity modulated arc therapy deliveries., Phys. Med. Biol. 53 (22), 6419-6436 (2008). 10.1088/0031-9155/53/22/010
-
(2008)
Phys. Med. Biol.
, vol.53
, Issue.22
, pp. 6419-6436
-
-
Oliver, M.1
Gladwish, A.2
Staruch, R.3
Craig, J.4
Gaede, S.5
Chen, J.6
Wong, E.7
-
14
-
-
70350745253
-
Comparing the accuracy of four-dimensional photon dose calculations with three-dimensional calculations using moving and deforming phantoms
-
10.1118/1.3238482
-
Y. Y. Vinogradskiy, P. Balter, D. S. Followill, P. E. Alvarez, R. A. White, and G. Starkschall, Comparing the accuracy of four-dimensional photon dose calculations with three-dimensional calculations using moving and deforming phantoms., Med. Phys. 36 (11), 5000-5006 (2009). 10.1118/1.3238482
-
(2009)
Med. Phys.
, vol.36
, Issue.11
, pp. 5000-5006
-
-
Vinogradskiy, Y.Y.1
Balter, P.2
Followill, D.S.3
Alvarez, P.E.4
White, R.A.5
Starkschall, G.6
-
15
-
-
0037037830
-
A basic study of some normoxic polymer gel dosimeters
-
10.1088/0031-9155/47/19/301
-
Y. De Deene, C. Hurley, A. Venning, K. Vergote, Mather M, B. J. Healy, and C. Baldock, A basic study of some normoxic polymer gel dosimeters., Phys. Med. Biol. 47 (19), 3441-3463 (2002). 10.1088/0031-9155/47/19/301
-
(2002)
Phys. Med. Biol.
, vol.47
, Issue.19
, pp. 3441-3463
-
-
De Deene, Y.1
Hurley, C.2
Venning, A.3
Vergote, K.4
Mather, M.5
Healy, B.J.6
Baldock, C.7
-
16
-
-
0037151132
-
Dose-response stability and integrity of the dose distribution of various polymer gel dosimeters
-
10.1088/0031-9155/47/14/307
-
Y. De Deene, A. Venning, C. Hurley, B. J. Healy, and C. Baldock, Dose-response stability and integrity of the dose distribution of various polymer gel dosimeters., Phys. Med. Biol. 47 (14), 2459-2470 (2002). 10.1088/0031-9155/47/14/307
-
(2002)
Phys. Med. Biol.
, vol.47
, Issue.14
, pp. 2459-2470
-
-
De Deene, Y.1
Venning, A.2
Hurley, C.3
Healy, B.J.4
Baldock, C.5
-
17
-
-
31344459574
-
The fundamental radiation properties of normoxic polymer gel dosimeters: A comparison between a methacrylic acid based gel and acrylamide based gels
-
10.1088/0031-9155/51/3/012
-
Y. De Deene, K. Vergote, C. Claeys, and C. De Wagter, The fundamental radiation properties of normoxic polymer gel dosimeters: a comparison between a methacrylic acid based gel and acrylamide based gels., Phys. Med. Biol. 51, 653-673 (2006). 10.1088/0031-9155/51/3/012
-
(2006)
Phys. Med. Biol.
, vol.51
, pp. 653-673
-
-
De Deene, Y.1
Vergote, K.2
Claeys, C.3
De Wagter, C.4
-
18
-
-
17844363749
-
Radiological properties of normoxic polymer gel dosimeters
-
10.1118/1.1881812
-
A. J. Venning, K. N. Nitschke, P. J. Keall, and Baldock C, Radiological properties of normoxic polymer gel dosimeters., Med. Phys. 32 (4), 1047-1053 (2005). 10.1118/1.1881812
-
(2005)
Med. Phys.
, vol.32
, Issue.4
, pp. 1047-1053
-
-
Venning, A.J.1
Nitschke, K.N.2
Keall, P.J.3
Baldock, C.4
-
19
-
-
34147096861
-
Introducing gel dosimetry in a clinical environment: Customization of polymer gel composition and magnetic resonance imaging parameters used for 3D dose verifications in radiosurgery and intensity modulated radiotherapy
-
10.1118/1.2712042
-
R. A. Crescenti, S. G. Scheib, U. Schneider, and S. Gianolini, Introducing gel dosimetry in a clinical environment: customization of polymer gel composition and magnetic resonance imaging parameters used for 3D dose verifications in radiosurgery and intensity modulated radiotherapy., Med. Phys. 34 (4), 1286-1297 (2007). 10.1118/1.2712042
-
(2007)
Med. Phys.
, vol.34
, Issue.4
, pp. 1286-1297
-
-
Crescenti, R.A.1
Scheib, S.G.2
Schneider, U.3
Gianolini, S.4
-
20
-
-
3242717970
-
Dose verification in clinical IMRT prostate incidents
-
10.1016/j.ijrob2004.04.029
-
P. Sandilos, A. Angelopoulos, P. Baras, K. Dardoufas, P. Karaiskos, P. Kipouros, M. Kozicki, J. M. Rosiak, L. Sakelliou, I. Seimenis, and L. Vlahos, Dose verification in clinical IMRT prostate incidents., Int. J. Radiat. Oncol., Biol., Phys. 59 (5), 1540-1547 (2004). 10.1016/j.ijrobp.2004.04.029
-
(2004)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.59
, Issue.5
, pp. 1540-1547
-
-
Sandilos, P.1
Angelopoulos, A.2
Baras, P.3
Dardoufas, K.4
Karaiskos, P.5
Kipouros, P.6
Kozicki, M.7
Rosiak, J.M.8
Sakelliou, L.9
Seimenis, I.10
Vlahos, L.11
-
21
-
-
0037691914
-
Commissioning and quality assurance of the Pinnacle3 radiotherapy treatment planning system for external beam photons
-
10.1259/bjr/42085182
-
J. L. Bedford, P. J. Childs, V. Nordmark Hansen, M. A. Mosleh-Shirazi, F. Verhaegen, and A. P. Warrington, Commissioning and quality assurance of the Pinnacle3 radiotherapy treatment planning system for external beam photons., Br. J. Radiol. 76, 163-176 (2003). 10.1259/bjr/42085182
-
(2003)
Br. J. Radiol.
, vol.76
, pp. 163-176
-
-
Bedford, J.L.1
Childs, P.J.2
Nordmark Hansen, V.3
Mosleh-Shirazi, M.A.4
Verhaegen, F.5
Warrington, A.P.6
-
22
-
-
33845614453
-
A magnetic resonance imaging study of prostate deformation relative to implanted gold fiducial markers
-
10.1016/j.ijrob2006.08.021
-
A. M. Nichol, K. K. Brock, G. A. Lockwood, M. Math, D. J. Moseley, T. Rosewall, P. R. Warde, C. N. Catton, and D. A. Jaffray, A magnetic resonance imaging study of prostate deformation relative to implanted gold fiducial markers., Int. J. Radiat. Oncol., Biol., Phys. 67 (1), 48-56 (2007). 10.1016/j.ijrobp.2006.08.021
-
(2007)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.67
, Issue.1
, pp. 48-56
-
-
Nichol, A.M.1
Brock, K.K.2
Lockwood, G.A.3
Math, M.4
Moseley, D.J.5
Rosewall, T.6
Warde, P.R.7
Catton, C.N.8
Jaffray, D.A.9
-
23
-
-
38149136353
-
Soft tissue elastometer
-
10.1016/j.medengphy.2007.02.007
-
V. Egorov, S. Tsyuryupa, S. Kanilo, M. Kogit, and A. Sarvazyan, Soft tissue elastometer., Med. Eng. Phys. 30 (2), 206-212 (2008). 10.1016/j.medengphy.2007.02.007
-
(2008)
Med. Eng. Phys.
, vol.30
, Issue.2
, pp. 206-212
-
-
Egorov, V.1
Tsyuryupa, S.2
Kanilo, S.3
Kogit, M.4
Sarvazyan, A.5
-
24
-
-
0043246587
-
Measuring the elastic modulus of ex vivo small tissue samples
-
10.1088/0031-9155/48/14/310
-
A. Samani, J. Bishop, C. Luginbuhl, and D. B. Plewes, Measuring the elastic modulus of ex vivo small tissue samples., Phys. Med. Biol. 48 (14), 2183-2198 (2003). 10.1088/0031-9155/48/14/310
-
(2003)
Phys. Med. Biol.
, vol.48
, Issue.14
, pp. 2183-2198
-
-
Samani, A.1
Bishop, J.2
Luginbuhl, C.3
Plewes, D.B.4
-
26
-
-
0032733524
-
Coronary venous oximetry using MRI
-
10.1002/(SICI)1522-2594(199911)42:51.0.CO;2-O
-
W. D. Foltz, N. Merchant, E. Downar, J. A. Stainsby, and G. A. Wright, Coronary venous oximetry using MRI., Magn. Reson. Med. 42 (5), 837-848 (1999). 10.1002/(SICI)1522-2594(199911)42:51.0.CO;2-O
-
(1999)
Magn. Reson. Med.
, vol.42
, Issue.5
, pp. 837-848
-
-
Foltz, W.D.1
Merchant, N.2
Downar, E.3
Stainsby, J.A.4
Wright, G.A.5
-
27
-
-
0038778574
-
2 relaxation
-
10.1002/mrm.v49:6
-
2 relaxation., Magn. Reson. Med. 49 (6), 1089-1097 (2003). 10.1002/mrm.v49:6
-
(2003)
Magn. Reson. Med.
, vol.49
, Issue.6
, pp. 1089-1097
-
-
Foltz, W.D.1
Al-Kwifi, O.2
Sussman, M.S.3
Stainsby, J.A.4
Wright, G.A.5
-
28
-
-
17844379967
-
Respiratory correlated cone beam CT
-
10.1118/1.1869074
-
J. J. Sonke, L. Zijp, P. Remeijer, and M. van Herk, Respiratory correlated cone beam CT., Med. Phys. 32 (4), 1176-1186 (2005). 10.1118/1.1869074
-
(2005)
Med. Phys.
, vol.32
, Issue.4
, pp. 1176-1186
-
-
Sonke, J.J.1
Zijp, L.2
Remeijer, P.3
Van Herk, M.4
-
29
-
-
38049049707
-
Contact surface and material nonlinearity modeling of human lungs
-
10.1088/0031-9155/53/1/022
-
A. Al-Mayah, J. Moseley, and K. K. Brock, Contact surface and material nonlinearity modeling of human lungs., Phys. Med. Biol. 53 (1), 305-317 (2008). 10.1088/0031-9155/53/1/022
-
(2008)
Phys. Med. Biol.
, vol.53
, Issue.1
, pp. 305-317
-
-
Al-Mayah, A.1
Moseley, J.2
Brock, K.K.3
-
30
-
-
0141520680
-
Evaluation of the gamma dose distribution comparison method
-
10.1118/1.1598711
-
D. A. Low and J. F. Dempsey, Evaluation of the gamma dose distribution comparison method., Med. Phys. 30 (9), 2455-2464 (2003). 10.1118/1.1598711
-
(2003)
Med. Phys.
, vol.30
, Issue.9
, pp. 2455-2464
-
-
Low, D.A.1
Dempsey, J.F.2
|