메뉴 건너뛰기




Volumn 81, Issue 3, 2012, Pages

Characterization of carotid atherosclerosis with black-blood carotid plaque imaging using variable flip-angle 3D turbo spin-echo: Comparison with 2D turbo spin-echo sequences

Author keywords

Carotid plaque; Magnetic resonance imaging; Turbo spin echo; Variable flip angle

Indexed keywords

ADULT; AGED; ARTICLE; ATHEROSCLEROTIC PLAQUE; CALCIFICATION; CAROTID ATHEROSCLEROSIS; CAROTID ENDARTERECTOMY; CLINICAL ARTICLE; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DIAGNOSTIC TEST ACCURACY STUDY; DIFFUSION WEIGHTED IMAGING; DISEASE CLASSIFICATION; ELECTRON SPIN RESONANCE; FEMALE; HISTOPATHOLOGY; HUMAN; HUMAN TISSUE; IMAGE QUALITY; IMAGING; INTERMETHOD COMPARISON; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; SUBMANDIBULAR GLAND; THREE DIMENSIONAL IMAGING; THREE DIMENSIONAL VARIABLE REFOCUSING FLIP ANGLE TURBO SPIN ECHO; TWO DIMENSIONAL TURBO SPIN ECHO; ULCER;

EID: 84856949467     PISSN: 0720048X     EISSN: 18727727     Source Type: Journal    
DOI: 10.1016/j.ejrad.2011.10.012     Document Type: Article
Times cited : (18)

References (20)
  • 1
    • 0026008977 scopus 로고
    • North American symptomatic carotid endarterectomy trial. Methods, patient characteristics, and progress
    • Investigators NASCE.T.
    • NASCE.T. Investigators North American symptomatic carotid endarterectomy trial. Methods, patient characteristics, and progress Stroke 22 6 1991 711 720
    • (1991) Stroke , vol.22 , Issue.6 , pp. 711-720
  • 2
  • 3
    • 0038338568 scopus 로고    scopus 로고
    • Prevalence of complicated carotid atheroma as detected by magnetic resonance direct thrombus imaging in patients with suspected carotid artery stenosis and previous acute cerebral ischemia
    • R.E. Murphy, A.R. Moody, and P.S. Morgan Prevalence of complicated carotid atheroma as detected by magnetic resonance direct thrombus imaging in patients with suspected carotid artery stenosis and previous acute cerebral ischemia Circulation 107 24 2003 3053 3058
    • (2003) Circulation , vol.107 , Issue.24 , pp. 3053-3058
    • Murphy, R.E.1    Moody, A.R.2    Morgan, P.S.3
  • 4
    • 33847100904 scopus 로고    scopus 로고
    • Association between signal hyperintensity on T1-weighted MR imaging of carotid plaques and ipsilateral ischemic events
    • N. Yamada, M. Higashi, and R. Otsubo Association between signal hyperintensity on T1-weighted MR imaging of carotid plaques and ipsilateral ischemic events Am J Neuroradiol 28 2 2007 287 292
    • (2007) Am J Neuroradiol , vol.28 , Issue.2 , pp. 287-292
    • Yamada, N.1    Higashi, M.2    Otsubo, R.3
  • 5
    • 58149379242 scopus 로고    scopus 로고
    • Evaluation of carotid artery atherosclerotic plaque distribution by using long-axis high-resolution black-blood magnetic resonance imaging
    • K. Yoshida, H. Endo, and N. Sadamasa Evaluation of carotid artery atherosclerotic plaque distribution by using long-axis high-resolution black-blood magnetic resonance imaging J Neurosurg 109 6 2008 1042 1048
    • (2008) J Neurosurg , vol.109 , Issue.6 , pp. 1042-1048
    • Yoshida, K.1    Endo, H.2    Sadamasa, N.3
  • 6
    • 53749101001 scopus 로고    scopus 로고
    • In vivo 3D high-spatial-resolution MR imaging of intraplaque hemorrhage
    • R. Bitar, A.R. Moody, and G. Leung In vivo 3D high-spatial-resolution MR imaging of intraplaque hemorrhage Radiology 249 1 2008 259 267
    • (2008) Radiology , vol.249 , Issue.1 , pp. 259-267
    • Bitar, R.1    Moody, A.R.2    Leung, G.3
  • 7
    • 0026320313 scopus 로고
    • Fast selective black blood MR imaging
    • R.R. Edelman, D. Chien, and D. Kim Fast selective black blood MR imaging Radiology 181 3 1991 655 660
    • (1991) Radiology , vol.181 , Issue.3 , pp. 655-660
    • Edelman, R.R.1    Chien, D.2    Kim, D.3
  • 8
    • 0029978378 scopus 로고    scopus 로고
    • Black blood T2-weighted inversion-recovery MR imaging of the heart
    • O.P. Simonetti, J.P. Finn, R.D. White, G. Laub, and D.A. Henry Black blood T2-weighted inversion-recovery MR imaging of the heart Radiology 199 1 1996 49 57
    • (1996) Radiology , vol.199 , Issue.1 , pp. 49-57
    • Simonetti, O.P.1    Finn, J.P.2    White, R.D.3    Laub, G.4    Henry, D.A.5
  • 9
    • 49049113454 scopus 로고    scopus 로고
    • Characterization of atherosclerotic plaque of carotid arteries with histopathological correlation: Vascular wall MR imaging vs color Doppler ultrasonography (US)
    • Y. Watanabe, M. Nagayama, and T. Suga Characterization of atherosclerotic plaque of carotid arteries with histopathological correlation: vascular wall MR imaging vs color Doppler ultrasonography (US) J Magn Reson Imaging 28 2 2008 478 485
    • (2008) J Magn Reson Imaging , vol.28 , Issue.2 , pp. 478-485
    • Watanabe, Y.1    Nagayama, M.2    Suga, T.3
  • 10
    • 77953080216 scopus 로고    scopus 로고
    • Altered carotid plaque signal among different repetition times on T1-weighted magnetic resonance plaque imaging with self-navigated radial-scan technique
    • S. Narumi, M. Sasaki, and H. Ohba Altered carotid plaque signal among different repetition times on T1-weighted magnetic resonance plaque imaging with self-navigated radial-scan technique Neuroradiology 52 4 2010 285 290
    • (2010) Neuroradiology , vol.52 , Issue.4 , pp. 285-290
    • Narumi, S.1    Sasaki, M.2    Ohba, H.3
  • 11
    • 41949118497 scopus 로고    scopus 로고
    • Comparison between 2D and 3D high-resolution black-blood techniques for carotid artery wall imaging in clinically significant atherosclerosis
    • N. Balu, B. Chu, T.S. Hatsukami, C. Yuan, and V.L. Yarnykh Comparison between 2D and 3D high-resolution black-blood techniques for carotid artery wall imaging in clinically significant atherosclerosis J Magn Reson Imaging 27 4 2008 918 924
    • (2008) J Magn Reson Imaging , vol.27 , Issue.4 , pp. 918-924
    • Balu, N.1    Chu, B.2    Hatsukami, T.S.3    Yuan, C.4    Yarnykh, V.L.5
  • 12
    • 77649197700 scopus 로고    scopus 로고
    • Carotid arterial wall MRI at 3 T using 3D variable-flip-angle turbo spin-echo (TSE) with flow-sensitive dephasing (FSD)
    • Z. Fan, Z. Zhang, and Y.C. Chung Carotid arterial wall MRI at 3 T using 3D variable-flip-angle turbo spin-echo (TSE) with flow-sensitive dephasing (FSD) J Magn Reson Imaging 31 3 2010 645 654
    • (2010) J Magn Reson Imaging , vol.31 , Issue.3 , pp. 645-654
    • Fan, Z.1    Zhang, Z.2    Chung, Y.C.3
  • 13
    • 33644835410 scopus 로고    scopus 로고
    • Elimination of residual blood flow-related signal in 3D volume-selective TSE arterial wall imaging using velocity-sensitive phase reconstruction
    • L.A. Crowe, A. Varghese, R.H. Mohiaddin, G.Z. Yang, and D.N. Firmin Elimination of residual blood flow-related signal in 3D volume-selective TSE arterial wall imaging using velocity-sensitive phase reconstruction J Magn Reson Imaging 23 3 2006 416 421
    • (2006) J Magn Reson Imaging , vol.23 , Issue.3 , pp. 416-421
    • Crowe, L.A.1    Varghese, A.2    Mohiaddin, R.H.3    Yang, G.Z.4    Firmin, D.N.5
  • 14
    • 0037373303 scopus 로고    scopus 로고
    • Multiecho sequences with variable refocusing flip angles: Optimization of signal behavior using smooth transitions between pseudo steady states (TRAPS)
    • J. Hennig, M. Weigel, and K. Scheffler Multiecho sequences with variable refocusing flip angles: optimization of signal behavior using smooth transitions between pseudo steady states (TRAPS) Magn Reson Med 49 3 2003 527 535
    • (2003) Magn Reson Med , vol.49 , Issue.3 , pp. 527-535
    • Hennig, J.1    Weigel, M.2    Scheffler, K.3
  • 15
    • 33646449765 scopus 로고    scopus 로고
    • Fast spin echo sequences with very long echo trains: Design of variable refocusing flip angle schedules and generation of clinical T2 contrast
    • R.F. Busse, H. Hariharan, A. Vu, and J.H. Brittain Fast spin echo sequences with very long echo trains: design of variable refocusing flip angle schedules and generation of clinical T2 contrast Magn Reson Med 55 5 2006 1030 1037
    • (2006) Magn Reson Med , vol.55 , Issue.5 , pp. 1030-1037
    • Busse, R.F.1    Hariharan, H.2    Vu, A.3    Brittain, J.H.4
  • 16
    • 77649084063 scopus 로고    scopus 로고
    • Contrast-enhanced, three-dimensional, whole-brain, black-blood imaging: Application to small brain metastases
    • J. Park, and E.Y. Kim Contrast-enhanced, three-dimensional, whole-brain, black-blood imaging: application to small brain metastases Magn Reson Med 63 3 2010 553 561
    • (2010) Magn Reson Med , vol.63 , Issue.3 , pp. 553-561
    • Park, J.1    Kim, E.Y.2
  • 17
    • 84856975068 scopus 로고    scopus 로고
    • T1-weghted black-blood carotid plaque imaging using variable flip-angle 3D turbo spin-echo: Comparison with 2D turbo spin echo and 3D turbo field echo sequences
    • K. Takano, S. Yamashita, and K. Takemoto T1-weghted black-blood carotid plaque imaging using variable flip-angle 3D turbo spin-echo: comparison with 2D turbo spin echo and 3D turbo field echo sequences Med Bull Fuk Univ 38 2 2011 85 90
    • (2011) Med Bull Fuk Univ , vol.38 , Issue.2 , pp. 85-90
    • Takano, K.1    Yamashita, S.2    Takemoto, K.3
  • 18
    • 0029097154 scopus 로고
    • A definition of advanced types of atherosclerotic lesions and a histological classification of atherosclerosis. A report from the Committee on Vascular Lesions of the Council on Arteriosclerosis, American Heart Association
    • H.C. Stary, A.B. Chandler, and R.E. Dinsmore A definition of advanced types of atherosclerotic lesions and a histological classification of atherosclerosis. A report from the Committee on Vascular Lesions of the Council on Arteriosclerosis, American Heart Association Circulation 92 5 1995 1355 1374
    • (1995) Circulation , vol.92 , Issue.5 , pp. 1355-1374
    • Stary, H.C.1    Chandler, A.B.2    Dinsmore, R.E.3
  • 19
    • 49049096313 scopus 로고    scopus 로고
    • Modified electrocardiograph-triggered black-blood turbo spin-echo technique to improve T1-weighting in contrast-enhanced MRI of atherosclerotic carotid arteries
    • L. Boussel, G. Herigault, M. Sigovan, R. Loffroy, E. Canet-Soulas, and P.C. Douek Modified electrocardiograph-triggered black-blood turbo spin-echo technique to improve T1-weighting in contrast-enhanced MRI of atherosclerotic carotid arteries J Magn Reson Imaging 28 2 2008 533 537
    • (2008) J Magn Reson Imaging , vol.28 , Issue.2 , pp. 533-537
    • Boussel, L.1    Herigault, G.2    Sigovan, M.3    Loffroy, R.4    Canet-Soulas, E.5    Douek, P.C.6
  • 20
    • 35948971057 scopus 로고    scopus 로고
    • Improved suppression of plaque-mimicking artifacts in black-blood carotid atherosclerosis imaging using a multislice motion-sensitized driven-equilibrium (MSDE) turbo spin-echo (TSE) sequence
    • J. Wang, V.L. Yarnykh, T. Hatsukami, B. Chu, N. Balu, and C. Yuan Improved suppression of plaque-mimicking artifacts in black-blood carotid atherosclerosis imaging using a multislice motion-sensitized driven-equilibrium (MSDE) turbo spin-echo (TSE) sequence Magn Reson Med 58 5 2007 973 981
    • (2007) Magn Reson Med , vol.58 , Issue.5 , pp. 973-981
    • Wang, J.1    Yarnykh, V.L.2    Hatsukami, T.3    Chu, B.4    Balu, N.5    Yuan, C.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.