메뉴 건너뛰기




Volumn 23, Issue 1, 2012, Pages 46-54

Physiology of continuous-flow pumps

Author keywords

Continuous flow pumps; mechanical circulatory support; monitoring; physiology; rotary blood pump; ventricular assist devices

Indexed keywords

BLOOD PRESSURE MEASUREMENT; CARDIOGENIC SHOCK; CENTRAL VENOUS PRESSURE; ELECTROCARDIOGRAPHY; HEART ASSIST DEVICE; HEART FAILURE; HEMODYNAMICS; HUMAN; INSTRUMENTATION; NURSING; OXIMETRY; PULMONARY ARTERY; PULSE RATE; REVIEW; TIME;

EID: 84856847906     PISSN: 15597768     EISSN: 15597776     Source Type: Journal    
DOI: 10.1097/NCI.0b013e31824125fd     Document Type: Article
Times cited : (14)

References (17)
  • 1
    • 0038247954 scopus 로고    scopus 로고
    • Prologue: Ventricular assist devices and total artificial hearts: A historical perspective
    • DOI 10.1016/S0733-8651(02)00133-9
    • Frazier OH. Prologue: Ventricular assist devices and total artificial hearts. A historical perspective. Cardiol Clin. 2003;21(1):1-13. (Pubitemid 36612699)
    • (2003) Cardiology Clinics , vol.21 , Issue.1 , pp. 1-13
    • Frazier, O.H.1
  • 2
    • 79953239174 scopus 로고    scopus 로고
    • Developmental history of mechanical circulatory support
    • In: Frazier OH, Kirklin JK, eds, New York, NY Elsevier
    • Kirklin JK, Frazier OH. Developmental history of mechanical circulatory support. In: Frazier OH, Kirklin JK, eds. ISHLT Monograph Series: Mechanical Circulatory Support. Vol 1. New York, NY: Elsevier; 2006:1-8.
    • (2006) ISHLT Monograph Series: Mechanical Circulatory Support. , vol.1 , pp. 1-8
    • Kirklin, J.K.1    Frazier, O.H.2
  • 3
    • 77955396572 scopus 로고    scopus 로고
    • Current status of cardiac transplantation and left ventricular assist devices
    • Frazier OH. Current status of cardiac transplantation and left ventricular assist devices. Tex Heart Inst J. 2010;37(3): 319-321.
    • (2010) Tex Heart Inst J. , vol.37 , Issue.3 , pp. 319-321
    • Frazier, O.H.1
  • 4
    • 77955882771 scopus 로고    scopus 로고
    • Ventricular assist device: Saving the failing heart
    • Kurien S, Gallagher C. Ventricular assist device: Saving the failing heart. Prog Transplant. 2010;20(2):134-141.
    • (2010) Prog Transplant. , vol.20 , Issue.2 , pp. 134-141
    • Kurien, S.1    Gallagher, C.2
  • 5
    • 33644873240 scopus 로고    scopus 로고
    • Design considerations of volute geometry of a centrifugal blood pump
    • DOI 10.1111/j.1525-1594.2005.00163.x
    • Chan WK, Wong YW, Hu W. Design considerations of volute geometry of a centrifugal blood pump. Artif Organs. 2005;29(12):937-948. (Pubitemid 43943029)
    • (2005) Artificial Organs , vol.29 , Issue.12 , pp. 937-948
    • Chan, W.K.1    Wong, Y.W.2    Hu, W.3
  • 7
    • 26844505913 scopus 로고    scopus 로고
    • Chronic nonpulsatile blood flow is compatible with normal end-organ function: Implications for LVAD development
    • DOI 10.1007/s10047-005-0295-y
    • Saito S, Nishinaka T. Chronic nonpulsatile blood flow is compatible with normal end organ function: Implications for LVAD development. J Artif Organs. 2005;8:143-148. (Pubitemid 41464671)
    • (2005) Journal of Artificial Organs , vol.8 , Issue.3 , pp. 143-148
    • Saito, S.1    Nishinaka, T.2
  • 8
    • 70349989042 scopus 로고    scopus 로고
    • Ventricular assist devices: The challenges of outpatient management
    • Wilson S, Givertz M, Stewart G, Mudge G. Ventricular assist devices: The challenges of outpatient management. J Am Coll Cardiol. 2009;54:1547-1659.
    • (2009) J Am Coll Cardiol. , vol.54 , pp. 1547-1659
    • Wilson, S.1    Givertz, M.2    Stewart, G.3    Mudge, G.4
  • 9
    • 67349185641 scopus 로고    scopus 로고
    • Assessment of arterial blood pressure during support with an axial flow left ventricular assist device
    • Myers TJ, Bolmers M, Gregoric ID, Kar B, Frazier OH. Assessment of arterial blood pressure during support with an axial flow left ventricular assist device. J Heart Lung Transplant. 2009;28(5):423-427.
    • (2009) J Heart Lung Transplant. , vol.28 , Issue.5 , pp. 423-427
    • Myers, T.J.1    Bolmers, M.2    Gregoric, I.D.3    Kar, B.4    Frazier, O.H.5
  • 10
    • 84856831288 scopus 로고    scopus 로고
    • Ventricular assist device-how to obtain optimal benefits
    • In Shuhaiber J, ed, Rijeka, Croatia: InTech. Accessed December 29
    • Bielecka-Dabrowa A, Banach M, Rysz J, Driscoll G. Ventricular assist device-how to obtain optimal benefits. In: Shuhaiber J, ed. Ventricular Assist Devices. Rijeka, Croatia: InTech. http://www.intechopen.com/source/pdfs/15748/ InTech-Ventricular-assist-device-how-to-obtain-optimal-benefits-.pdf. Accessed December 29, 2011.
    • (2011) Ventricular Assist Devices
    • Bielecka-Dabrowa, A.1    Banach, M.2    Rysz, J.3    Driscoll, G.4
  • 12
    • 34547565236 scopus 로고    scopus 로고
    • Suction Events During Left Ventricular Support and Ventricular Arrhythmias
    • DOI 10.1016/j.healun.2007.05.011, PII S1053249807004032
    • Vollkron M, Voitl P, Ta J, Wiesenthaler G, Schima H. Suction events during left ventricular support and ventricular arrhythmias. J Heart Lung Transplant. 2007;26(8):819-825. (Pubitemid 47199071)
    • (2007) Journal of Heart and Lung Transplantation , vol.26 , Issue.8 , pp. 819-825
    • Vollkron, M.1    Voitl, P.2    Ta, J.3    Wieselthaler, G.4    Schima, H.5
  • 13
    • 29244462314 scopus 로고    scopus 로고
    • Left ventricular support by axial flow pump: The echocardiographic approach to device malfunction
    • Catena E, Milazzo F, Montorsi E, et al. Left ventricular support by axial flow pump: The echocardiographic approach to device malfunction. J Am Soc Echocardiogr. 2005; 18(12):1422.e7-1422.e13.
    • (2005) J Am Soc Echocardiogr. , vol.18 , Issue.12
    • Catena, E.1    Milazzo, F.2    Montorsi, E.3
  • 15
    • 77953610725 scopus 로고    scopus 로고
    • Pulmonary hypertension in heart failure
    • Guglin M, Khan H. Pulmonary hypertension in heart failure. J Cardiac Fail. 2010;16(6):461-474.
    • (2010) J Cardiac Fail. , vol.16 , Issue.6 , pp. 461-474
    • Guglin, M.1    Khan, H.2
  • 16
    • 36048988032 scopus 로고    scopus 로고
    • Aortic Regurgitation During Left Ventricular Assist Device Support
    • DOI 10.1016/j.healun.2007.07.044, PII S1053249807006067
    • Hagbi D, Suselbeck T, Saur J. Aortic regurgitation during left ventricular assist device support. J Heart Lung Transplant. 2007;26(11):1220- 1221. (Pubitemid 350088512)
    • (2007) Journal of Heart and Lung Transplantation , vol.26 , Issue.11 , pp. 1220-1221
    • Haghi, D.1    Suselbeck, T.2    Saur, J.3
  • 17
    • 78650086786 scopus 로고    scopus 로고
    • Unforeseen consequences of therapy with continuous-flow pumps
    • Frazier OH. Unforeseen consequences of therapy with continuous-flow pumps. Circ Heart Fail. 2010;3:647-649.
    • (2010) Circ Heart Fail. , vol.3 , pp. 647-649
    • Frazier, O.H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.