메뉴 건너뛰기




Volumn 57, Issue 4, 2012, Pages

Reducing the staircasing error in computational dosimetry of low-frequency electromagnetic fields

Author keywords

[No Author keywords available]

Indexed keywords

ANALYTICAL SOLUTIONS; COMPUTATIONAL DOSIMETRY; CURVED BOUNDARY; ELECTRICAL CONDUCTIVITY; EXTREMELY LOW FREQUENCIES; FINITE DIFFERENCE; HUMAN BODIES; HUMAN HEAD MODEL; INDUCED ELECTRIC FIELDS; INTERMEDIATE FREQUENCIES; LOW FREQUENCY ELECTROMAGNETIC FIELD; NUMERICAL ERRORS; STAIRCASE APPROXIMATION; STAIRCASE GRIDS; VOXEL MODELS;

EID: 84856832075     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/57/4/N25     Document Type: Article
Times cited : (107)

References (21)
  • 1
    • 34248369798 scopus 로고    scopus 로고
    • Numerical dosimetry ELF: Accuracy of the method, variability of models and parameters, and the implication for quantifying guidelines
    • DOI 10.1097/01.HP.0000251249.00507.ca, PII 0000403220070600000004
    • Bahr A, Bolz T and Hennes C 2007 Numerical dosimetry ELF: accuracy of the method, variability of models and parameters, and the implication for quantifying guidelines Health Phys. 92 52130 (Pubitemid 46742932)
    • (2007) Health Physics , vol.92 , Issue.6 , pp. 521-530
    • Bahr, A.1    Bolz, T.2    Hennes, C.3
  • 2
    • 0037149994 scopus 로고    scopus 로고
    • Modelling fields induced in humans by 50/60 Hz magnetic fields: Reliability of the results and effects of model variations
    • DOI 10.1088/0031-9155/47/8/311, PII S0031915502294518
    • Caputa K, Dimbylow P J, Dawson T W and Stuchly M A 2002 Modelling fields induced in humans by 50/60 Hz magnetic fields: reliability of the results and effects of model variations Phys. Med. Biol. 47 13918 (Pubitemid 34495632)
    • (2002) Physics in Medicine and Biology , vol.47 , Issue.8 , pp. 1391-1398
    • Caputa, K.1    Dimbylow, P.J.2    Dawson, T.W.3    Stuchly, M.A.4
  • 3
    • 0032069710 scopus 로고    scopus 로고
    • High-resolution organ dosimetry for human exposure to low-frequency magnetic fields
    • PII S0018946498030088
    • Dawson T and Stuchly M 1998 High-resolution organ dosimetry for human exposure to low-frequency magnetic fields IEEE Trans. Magn. 34 70818 (Pubitemid 128738642)
    • (1998) IEEE Transactions on Magnetics , vol.34 , Issue.3 , pp. 708-718
    • Dawson, T.W.1    Stuchly, M.A.2
  • 4
    • 0030634633 scopus 로고    scopus 로고
    • Influence of Human Model Resolution on Computed Currents Induced in Organs by 60-Hz Magnetic Fields
    • Dawson T W, Caputa K and Stuchly M A 1997 Influence of human model resolution on computed currents induced in organs by 60 Hz magnetic fields Bioelectromagnetics 18 47890 (Pubitemid 127476513)
    • (1997) Bioelectromagnetics , vol.18 , Issue.7 , pp. 478-490
    • Dawson, T.W.1    Caputa, K.2    Stuchly, M.A.3
  • 6
    • 0035388587 scopus 로고    scopus 로고
    • Evaluation of modeling accuracy of power frequency field interactions with the human body
    • Dawson T W, Potter M and Stuchly M A 2001 Evaluation of modeling accuracy of power frequency field interactions with the human body Appl. Comput. Electromagn. Soc. J. 16 16272
    • (2001) Appl. Comput. Electromagn. Soc. J. , vol.16 , pp. 162-172
    • Dawson, T.W.1    Potter, M.2    Stuchly, M.A.3
  • 7
    • 16444369285 scopus 로고    scopus 로고
    • Development of the female voxel phantom, NAOMI, and its application to calculations of induced current densities and electric fields from applied low frequency magnetic and electric fields
    • DOI 10.1088/0031-9155/50/6/002
    • Dimbylow P 2005 Development of the female voxel phantom, NAOMI, and its application to calculations of induced current densities and electric fields from applied low frequency magnetic and electric fields Phys. Med. Biol. 50 104770 (Pubitemid 40477279)
    • (2005) Physics in Medicine and Biology , vol.50 , Issue.6 , pp. 1047-1070
    • Dimbylow, P.1
  • 8
    • 77957672708 scopus 로고    scopus 로고
    • The effects of body posture, anatomy, age and pregnancy on the calculation of induced current densities at 50 Hz
    • Dimbylow P and Findlay R 2010 The effects of body posture, anatomy, age and pregnancy on the calculation of induced current densities at 50 Hz Radiat. Prot. Dosim. 139 5328
    • (2010) Radiat. Prot. Dosim. , vol.139 , pp. 532-538
    • Dimbylow, P.1    Findlay, R.2
  • 9
    • 0031910772 scopus 로고    scopus 로고
    • Induced current densities from low-frequency magnetic fields in a 2 mm resolution, anatomically realistic model of the body
    • DOI 10.1088/0031-9155/43/2/001, PII S0031915598877737
    • Dimbylow P J 1998 Induced current densities from low-frequency magnetic fields in a 2 mm resolution, anatomically realistic model of the body Phys. Med. Biol. 43 22130 (Pubitemid 28100128)
    • (1998) Physics in Medicine and Biology , vol.43 , Issue.2 , pp. 221-230
    • Dimbylow, P.J.1
  • 10
    • 70349786735 scopus 로고    scopus 로고
    • Electrical conductivity of tissue at frequencies below 1 MHz
    • Gabriel C, Peyman A and Grant E H 2009 Electrical conductivity of tissue at frequencies below 1 MHz Phys. Med. Biol. 54 486378
    • (2009) Phys. Med. Biol. , vol.54 , pp. 4863-4878
    • Gabriel, C.1    Peyman, A.2    Grant, E.H.3
  • 11
    • 0029957193 scopus 로고    scopus 로고
    • The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues
    • DOI 10.1088/0031-9155/41/11/003
    • Gabriel S, Lau R W and Gabriel C 1996 The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues Phys. Med. Biol. 41 227193 (Pubitemid 26376903)
    • (1996) Physics in Medicine and Biology , vol.41 , Issue.11 , pp. 2271-2293
    • Gabriel, S.1    Lau, R.W.2    Gabriel, C.3
  • 12
    • 79960353397 scopus 로고    scopus 로고
    • An electric field induced in the retina and brain at threshold magnetic flux density causing magnetophosphenes
    • Hirata A, Takano Y, Fujiwara O, Dovan T and Kavet R 2011 An electric field induced in the retina and brain at threshold magnetic flux density causing magnetophosphenes Phys. Med. Biol. 56 4091101
    • (2011) Phys. Med. Biol. , vol.56 , pp. 4091-4101
    • Hirata, A.1    Takano, Y.2    Fujiwara, O.3    Dovan, T.4    Kavet, R.5
  • 13
    • 77951161361 scopus 로고    scopus 로고
    • Effect of the averaging volume and algorithm on the in situ electric field for uniform electric- and magnetic-field exposures
    • Hirata A, Takano Y, Kamimura Y and Fujiwara O 2010 Effect of the averaging volume and algorithm on the in situ electric field for uniform electric- and magnetic-field exposures Phys. Med. Biol. 55 N24352
    • (2010) Phys. Med. Biol. , vol.55
    • Hirata, A.1    Takano, Y.2    Kamimura, Y.3    Fujiwara, O.4
  • 14
    • 68349104254 scopus 로고    scopus 로고
    • In situ electric field and current density in Japanese male and female models for uniform magnetic field exposures
    • Hirata A, Wake K, Watanabe S and Taki M 2009 In situ electric field and current density in Japanese male and female models for uniform magnetic field exposures Radiat. Prot. Dosim. 135 27275
    • (2009) Radiat. Prot. Dosim. , vol.135 , pp. 272-275
    • Hirata, A.1    Wake, K.2    Watanabe, S.3    Taki, M.4
  • 15
    • 78649594749 scopus 로고    scopus 로고
    • Guidelines for limiting exposure to time-varying electric and magnetic fields (1 Hz to 100 kHz)
    • ICNIRP 2010 Guidelines for limiting exposure to time-varying electric and magnetic fields (1 Hz to 100 kHz) Health Phys. 99 81836 (Available at http://www.icnirp.de/documents/LFgdl.pdf)
    • (2010) Health Phys. , vol.99 , pp. 818-836
  • 17
    • 58149271156 scopus 로고    scopus 로고
    • Computational estimation of magnetically induced electric fields in a rotating head
    • Ilvonen S and Laakso I 2009 Computational estimation of magnetically induced electric fields in a rotating head Phys. Med. Biol. 54 34151
    • (2009) Phys. Med. Biol. , vol.54 , pp. 341-351
    • Ilvonen, S.1    Laakso, I.2
  • 18
    • 80053192521 scopus 로고    scopus 로고
    • Pre- and post-natal exposure of children to EMF generated by domestic induction cookers
    • Kos B, Vali B, Miklavi D, Kotnik T and Gajek P 2011 Pre- and post-natal exposure of children to EMF generated by domestic induction cookers Phys. Med. Biol. 56 614960
    • (2011) Phys. Med. Biol. , vol.56 , pp. 6149-6160
    • Kos, B.1    Vali, B.2    Miklavi, D.3    Kotnik, T.4    Gajek, P.5
  • 19
    • 0347093559 scopus 로고    scopus 로고
    • Development of realistic high-resolution whole-body voxel models of Japanese adult males and females of average height and weight, and application of models to radio-frequency electromagnetic-field dosimetry
    • DOI 10.1088/0031-9155/49/1/001, PII S0031915504655692
    • Nagaoka T, Watanabe S, Sakurai K, Kunieda E, Watanabe S, Taki M and Yamanaka Y 2004 Development of realistic high-resolution whole-body voxel models of Japanese adult males and females of average height and weight, and application of models to radio-frequency electromagnetic-field dosimetry Phys. Med. Biol. 49 115 (Pubitemid 38100619)
    • (2004) Physics in Medicine and Biology , vol.49 , Issue.1 , pp. 1-15
    • Nagaoka, T.1    Watanabe, S.2    Sakurai, K.3    Kunieda, E.4    Watanabe, S.5    Taki, M.6    Yamanaka, Y.7
  • 20
    • 33847721458 scopus 로고    scopus 로고
    • Low-frequency dosimetry of inhomogeneous magnetic fields using the coil source model and the household appliance
    • DOI 10.1109/TBME.2006.890507, 19
    • Nishizawa S, Landstorfer F and Kamimura Y 2007 Low-frequency dosimetry of inhomogeneous magnetic fields using the coil source model and the household appliance IEEE Trans. Biomed. Eng. 54 497502 (Pubitemid 46371239)
    • (2007) IEEE Transactions on Biomedical Engineering , vol.54 , Issue.3 , pp. 497-502
    • Nishizawa, S.1    Landstorfer, F.M.2    Kamimura, Y.3
  • 21
    • 1842421879 scopus 로고    scopus 로고
    • Equivalent dipole moment method to characterize magnetic fields generated by electric appliances: Extension to intermediate frequencies of up to 100 kHz
    • Yamazaki K, Kawamoto T, Fujinami H and Shigemitsu T 2004 Equivalent dipole moment method to characterize magnetic fields generated by electric appliances: extension to intermediate frequencies of up to 100 kHz IEEE Trans. Electromagn. Compat. 46 11520
    • (2004) IEEE Trans. Electromagn. Compat. , vol.46 , pp. 115-120
    • Yamazaki, K.1    Kawamoto, T.2    Fujinami, H.3    Shigemitsu, T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.