메뉴 건너뛰기




Volumn 27, Issue 3, 2012, Pages 1433-1443

Exploring inherent damping characteristic of LCL-filters for three-phase grid-connected voltage source inverters

Author keywords

Current control; grid connected inverters; LCL filter; resonance damping

Indexed keywords

ACTIVE DAMPING; COMPENSATION GAIN; COMPENSATION STRATEGY; CONTROL LOOP; DAMPING CHARACTERISTICS; DESIGN CRITERION; DESIGN GUIDELINES; FUNDAMENTAL COMPONENT; GRID CONNECTED INVERTERS; GRID-CONNECTED; LCL FILTERS; OPTIMUM DAMPING; OVERMODULATION; PASSIVE DAMPING; RESONANCE DAMPING; SECOND ORDERS; STATE OBSERVER; SYSTEM DAMPING; VOLTAGE SOURCE INVERTER;

EID: 84856831926     PISSN: 08858993     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPEL.2011.2162342     Document Type: Article
Times cited : (396)

References (30)
  • 1
    • 26844497165 scopus 로고    scopus 로고
    • Design and control of an LCL-filter-based three-phase active rectifier
    • DOI 10.1109/TIA.2005.853373
    • M. Liserre, F. Blaabjerg, and S. Hansen, "Design and control of an LCLfilter-based three-phase active rectifier, " IEEE Trans. Ind. Appl., vol. 41, no. 5, pp. 1281-1291, Sep./Oct. 2005. (Pubitemid 41444646)
    • (2005) IEEE Transactions on Industry Applications , vol.41 , Issue.5 , pp. 1281-1291
    • Liserre, M.1    Blaabjerg, F.2    Hansen, S.3
  • 2
    • 85008065287 scopus 로고    scopus 로고
    • Control of three-level PWM converter applied to variable-speed-type turbines
    • Jan.
    • M. Malinowski, S. Stynski, W. Kolomyjski, and M. P. Kazmierkowski, "Control of three-level PWM converter applied to variable-speed-type turbines, " IEEE Trans. Ind. Electron., vol. 56, no. 1, pp. 69-77, Jan. 2009.
    • (2009) IEEE Trans. Ind. Electron. , vol.56 , Issue.1 , pp. 69-77
    • Malinowski, M.1    Stynski, S.2    Kolomyjski, W.3    Kazmierkowski, M.P.4
  • 3
    • 66749117698 scopus 로고    scopus 로고
    • Design and implementation of a robust current controller for VSI connected to the grid through an LCL-filter
    • Jun.
    • I. J. Gabe, V. F. Montagner, and H. Pinheiro, "Design and implementation of a robust current controller for VSI connected to the grid through an LCL-filter, " IEEE Trans. Power Electron., vol. 24, no. 6, pp. 1444-1452, Jun. 2009.
    • (2009) IEEE Trans. Power Electron. , vol.24 , Issue.6 , pp. 1444-1452
    • Gabe, I.J.1    Montagner, V.F.2    Pinheiro, H.3
  • 4
    • 0038630802 scopus 로고    scopus 로고
    • Grid current regulation of a three-phase voltage source inverter with an LCL input filter
    • Jan.
    • E. Twining and D. G. Holmes, "Grid current regulation of a three-phase voltage source inverter with an LCL input filter, " IEEE Trans. Power Electron., vol. 18, no. 1, pp. 373-380, Jan. 2003.
    • (2003) IEEE Trans. Power Electron. , vol.18 , Issue.1 , pp. 373-380
    • Twining, E.1    Holmes, D.G.2
  • 5
    • 70350407147 scopus 로고    scopus 로고
    • Parameter design of a two-current-loop controller used in a grid-connected inverter system with LCL-filter
    • Nov.
    • F. Liu, Y. Zhou, S. X. Duan, J. J. Yin, B. Y. Liu, and F. R. Liu, "Parameter design of a two-current-loop controller used in a grid-connected inverter system with LCL-filter, " IEEE Trans. Ind. Electron., vol. 56, no. 11, pp. 4483-4491, Nov. 2009.
    • (2009) IEEE Trans. Ind. Electron. , vol.56 , Issue.11 , pp. 4483-4491
    • Liu, F.1    Zhou, Y.2    Duan, S.X.3    Yin, J.J.4    Liu, B.Y.5    Liu, F.R.6
  • 6
    • 70149112316 scopus 로고    scopus 로고
    • Design and control for three-phase grid-connected photovoltaic inverter with LCL-filter
    • Y. Chen and F. Liu, "Design and control for three-phase grid-connected photovoltaic inverter with LCL-filter, " in Proc. 2009 IEEE Circuits Syst. Int. Conf., pp. 1-4.
    • Proc. 2009 IEEE Circuits Syst. Int. Conf. , pp. 1-4
    • Chen, Y.1    Liu, F.2
  • 7
    • 0031100327 scopus 로고    scopus 로고
    • A novel control to actively damp resonance in input LC filter of a three-phase voltage source converter
    • PII S0093999497015363
    • V. Blasko and V. Kaura, "A novel control to actively damp resonance in input LC filter of a three-phase voltage source converter, " IEEE Trans. Ind. Appl., vol. 33, no. 2, pp. 542-550, Mar./Apr. 1997. (Pubitemid 127828210)
    • (1997) IEEE Transactions on Industry Applications , vol.33 , Issue.2 , pp. 542-550
    • Blasko, V.1    Kaura, V.2
  • 8
    • 33947133639 scopus 로고    scopus 로고
    • Digital current control of a voltage source converter with active damping of LCL resonance
    • DOI 10.1109/TPEL.2006.880271
    • E. Wu and P. W. Lehn, "Digital current control of a voltage source converter with active damping of LCL resonance, " IEEE Trans. Power Electron., vol. 21, no. 5, pp. 1364-1373, May 2006. (Pubitemid 46405250)
    • (2006) IEEE Transactions on Power Electronics , vol.21 , Issue.5 , pp. 1364-1373
    • Wu, E.1    Lehn, P.W.2
  • 9
    • 77954886269 scopus 로고    scopus 로고
    • Investigation of active damping approaches for PI-based current control of grid-connected pulse width modulation converters with LCL-filters
    • Jul./Aug.
    • J. Dannehl, F. W. Fuchs, S. Hansen, and P. B. Thogersen, "Investigation of active damping approaches for PI-based current control of grid-connected pulse width modulation converters with LCL-filters, " IEEE Trans Ind. Appl., vol. 46, no. 4, pp. 1509-1517, Jul./Aug. 2010.
    • (2010) IEEE Trans Ind. Appl. , vol.46 , Issue.4 , pp. 1509-1517
    • Dannehl, J.1    Fuchs, F.W.2    Hansen, S.3    Thogersen, P.B.4
  • 10
    • 42549095014 scopus 로고    scopus 로고
    • A simple voltage sensorless active damping scheme for three-phase PWM converters with an LCL filter
    • DOI 10.1109/TIE.2008.917066
    • M. Malinowski and S. Bernet, "A simple voltage sensorless active damping scheme for three-phase PWM converters with an LCL-filter, " IEEE Trans. Ind. Electron., vol. 55, no. 4, pp. 1876-1880, Apr. 2008. (Pubitemid 351586002)
    • (2008) IEEE Transactions on Industrial Electronics , vol.55 , Issue.4 , pp. 1876-1880
    • Malinowski, M.1    Bernet, S.2
  • 11
    • 77952274850 scopus 로고    scopus 로고
    • Performance improvement of LCL-filter-based grid-connected inverters using PQR power transformation
    • Ma.
    • H. G. Jeong, K. B. Lee, S. Choi, andW. Choi, "Performance improvement of LCL-filter-based grid-connected inverters using PQR power transformation, " IEEE Trans. Power Electron., vol. 25, no. 5, pp. 1320-1330, May 2010.
    • (2010) IEEE Trans. Power Electron. , vol.25 , Issue.5 , pp. 1320-1330
    • Jeong, H.G.1    Lee, K.B.2    Choi Andw. Choi, S.3
  • 12
    • 60449104954 scopus 로고    scopus 로고
    • Explicit model-predictive control of aPWM inverter with an LCL-filter
    • Feb.
    • S. Mariethoz andM. Morari, "Explicit model-predictive control of aPWM inverter with an LCL-filter, " IEEE Trans. Ind. Electron., vol. 56, no. 2, pp. 389-399, Feb. 2009.
    • (2009) IEEE Trans. Ind. Electron. , vol.56 , Issue.2 , pp. 389-399
    • Mariethoz, S.1    Morari, M.2
  • 13
    • 35348885574 scopus 로고    scopus 로고
    • A modified direct power control strategy allowing the connection of three-phase inverters to the grid through LCL filters
    • DOI 10.1109/TIA.2007.904438
    • L. A. Serpa, S. Ponnaluri, P. M. Barbosa, and J. W. Kolar, "A modified direct power control strategy allowing the connection of three-phase inverters to the grid through LCL-filters, " IEEE Trans. Ind. Appl., vol. 43, no. 5, pp. 1388-1400, Sep./Oct. 2007. (Pubitemid 47570239)
    • (2007) IEEE Transactions on Industry Applications , vol.43 , Issue.5 , pp. 1388-1400
    • Serpa, L.A.1    Ponnaluri, S.2    Barbosa, P.M.3    Kolar, J.W.4
  • 14
    • 47249136567 scopus 로고    scopus 로고
    • An improved control strategy for grid-connected voltage source inverters with an LCL-filter
    • Jul.
    • G. Shen, D. Xu, L. Cao, and X. Zhu, "An improved control strategy for grid-connected voltage source inverters with an LCL-filter, " IEEE Trans. Power Electron., vol. 23, no. 4, pp. 1899-1906, Jul. 2008.
    • (2008) IEEE Trans. Power Electron. , vol.23 , Issue.4 , pp. 1899-1906
    • Shen, G.1    Xu, D.2    Cao, L.3    Zhu, X.4
  • 15
    • 60449091304 scopus 로고    scopus 로고
    • Limitations of voltage-oriented PI current control of grid-connected PWM rectifiers with LCL-filters
    • Feb.
    • J. Dannehl, C. Wessels, and F. W. Fuchs, "Limitations of voltage-oriented PI current control of grid-connected PWM rectifiers with LCL-filters, " IEEE Trans. Ind. Electron., vol. 56, no. 2, pp. 380-388, Feb. 2009.
    • (2009) IEEE Trans. Ind. Electron. , vol.56 , Issue.2 , pp. 380-388
    • Dannehl, J.1    Wessels, C.2    Fuchs, F.W.3
  • 17
    • 77952212263 scopus 로고    scopus 로고
    • Optimized design of stationary frame three-phase ac current regulators
    • Nov.
    • D. G. Holmes, T. A. Lipo, B. P. McGrath, and W. Y. Kong, "Optimized design of stationary frame three-phase ac current regulators, " IEEE Trans. Power Electron., vol. 24, no. 11, pp. 2417-2426, Nov. 2009.
    • (2009) IEEE Trans. Power Electron. , vol.24 , Issue.11 , pp. 2417-2426
    • Holmes, D.G.1    Lipo, T.A.2    McGrath, B.P.3    Kong, W.Y.4
  • 18
    • 0742303695 scopus 로고    scopus 로고
    • Genetic algorithm-based design of the active damping for an LCL-filter three-phase active rectifier
    • Jan.
    • M. Liserre, A. Dell' Aquilu, and F. Blaabjerg, "Genetic algorithm-based design of the active damping for an LCL-filter three-phase active rectifier, " IEEE Trans. Power Electron., vol. 19, no. 1, pp. 76-86, Jan. 2004.
    • (2004) IEEE Trans. Power Electron. , vol.19 , Issue.1 , pp. 76-86
    • Liserre, M.1    Dell Aquilu, A.2    Blaabjerg, F.3
  • 19
    • 52349111616 scopus 로고    scopus 로고
    • Design of an LCL-filter employing a symmetric geometry and its control in gridconnected inverter applications
    • K. J. Lee, N. J. Park, R. Y. Kim, D. H. Ha, and D. S. Hyun, "Design of an LCL-filter employing a symmetric geometry and its control in gridconnected inverter applications, " in Proc. 2008 IEEE Power Electron. Spec. Conf., pp. 963-966.
    • Proc. 2008 IEEE Power Electron. Spec. Conf. , pp. 963-966
    • Lee, K.J.1    Park, N.J.2    Kim, R.Y.3    Ha, D.H.4    Hyun, D.S.5
  • 20
    • 79959760422 scopus 로고    scopus 로고
    • Improved onecycle-control scheme for three-phase active rectifiers with input inductorcapacitor-inductor filters
    • Y. Tang, P. C. Loh, P. Wang, F. H. Choo, and K. K. Tan, "Improved onecycle-control scheme for three-phase active rectifiers with input inductorcapacitor-inductor filters, " IET Power Electron, vol. 4, no. 5, pp. 603-614, 2011.
    • (2011) IET Power Electron , vol.4 , Issue.5 , pp. 603-614
    • Tang, Y.1    Loh, P.C.2    Wang, P.3    Choo, F.H.4    Tan, K.K.5
  • 21
    • 66149152329 scopus 로고    scopus 로고
    • Design of LCL-filters of active-front-end twolevel voltage-source converters
    • May
    • K. Jalili and S. Bernet, "Design of LCL-filters of active-front-end twolevel voltage-source converters, " IEEE Trans. Ind. Electron., vol. 56, no. 5, pp. 1674-1689, May 2009.
    • (2009) IEEE Trans. Ind. Electron. , vol.56 , Issue.5 , pp. 1674-1689
    • Jalili, K.1    Bernet, S.2
  • 22
    • 21044442558 scopus 로고    scopus 로고
    • Active damping control of a high-power PWM current-source rectifier for line-current THD reduction
    • DOI 10.1109/TIE.2005.843939
    • J. C. Wiseman and B. Wu, "Active damping control of a high-power PWM current-source rectifier for line-current THD reduction, " IEEE Trans. Ind. Electron., vol. 52, no. 3, pp. 758-764, Jun. 2005. (Pubitemid 40871112)
    • (2005) IEEE Transactions on Industrial Electronics , vol.52 , Issue.3 , pp. 758-764
    • Wiseman, J.C.1    Wu, B.2
  • 23
    • 17644367516 scopus 로고    scopus 로고
    • Analysis of multiloop control strategies for LC/CL/LCL-filtered voltage-source and current-source inverters
    • DOI 10.1109/TIA.2005.844860
    • P. C. Loh and D. G. Holmes, "Analysis of multiloop control strategies for LC/CL/LCL-filtered voltage-source and current-source inverters, " IEEE Trans. Ind. Appl., vol. 41, no. 2, pp. 644-654, Mar./Apr. 2005. (Pubitemid 40564671)
    • (2005) IEEE Transactions on Industry Applications , vol.41 , Issue.2 , pp. 644-654
    • Loh, P.C.1    Holmes, D.G.2
  • 24
    • 0036442912 scopus 로고    scopus 로고
    • A controlmethod to damp oscillation in the inputLCfilter
    • P. A. Dahono, "A controlmethod to damp oscillation in the inputLCfilter, " in Proc. IEEE Power electron. Spec. Conf., 2002, vol. 4, pp. 1630-1635.
    • (2002) Proc. IEEE Power Electron. Spec. Conf. , vol.4 , pp. 1630-1635
    • Dahono, P.A.1
  • 25
    • 35348842797 scopus 로고    scopus 로고
    • Grid impedance estimation via excitation of LCL-filter resonance
    • DOI 10.1109/TIA.2007.904439
    • M. Liserre, F. Blaabjerg, and R. Teodorescu, "Grid impedance estimation via excitation of LCL-filter resonance, " IEEE Trans. Ind. Appl., vol. 43, no. 5, pp. 1401-1407, Sep./Oct. 2007. (Pubitemid 47570240)
    • (2007) IEEE Transactions on Industry Applications , vol.43 , Issue.5 , pp. 1401-1407
    • Liserre, M.1    Blaabjerg, F.2    Teodorescu, R.3
  • 26
    • 28444445586 scopus 로고    scopus 로고
    • Suppression of line voltage related distortion in current controlled grid connected inverters
    • DOI 10.1109/TPEL.2005.857557
    • T. Abeyasekera, C. M. Johnson, D. J. Atkinson, andM. Armstrong, "Suppression of line voltage related distortion in current controlled grid connected inverters, " IEEE Trans. Power Electron., vol. 20, no. 6, pp. 1393-1401, Nov. 2005. (Pubitemid 41723478)
    • (2005) IEEE Transactions on Power Electronics , vol.20 , Issue.6 , pp. 1393-1401
    • Abeyasekera, T.1    Johnson, C.M.2    Atkinson, D.J.3    Armstrong, M.4
  • 27
    • 80155201251 scopus 로고    scopus 로고
    • Full feedforward of grid voltage for grid-connected inverter with LCL-filter to suppress current distortion due to grid voltage harmonics
    • Dec.
    • X. Wang, X. Ruan, S. Liu, and C. K. Tse, "Full feedforward of grid voltage for grid-connected inverter with LCL-filter to suppress current distortion due to grid voltage harmonics, " IEEE Trans. Power Electron., vol. 25, no. 12, pp. 3119-3127, Dec. 2010.
    • (2010) IEEE Trans. Power Electron. , vol.25 , Issue.12 , pp. 3119-3127
    • Wang, X.1    Ruan, X.2    Liu, S.3    Tse, C.K.4
  • 28
    • 65949107554 scopus 로고    scopus 로고
    • Improved stationary frame AC current regulation using feedforward compensation of the load EMF
    • Washington, DC, CD record
    • W. Y. Kong, D. G. Holmes, and B. P. McGrath, "Improved stationary frame AC current regulation using feedforward compensation of the load EMF, " in Proc. IEEE Appl. Power Electron. Conf., Washington, DC, CD record, 2009, pp. 145-151.
    • (2009) Proc. IEEE Appl. Power Electron. Conf. , pp. 145-151
    • Kong, W.Y.1    Holmes, D.G.2    McGrath, B.P.3
  • 29
    • 0038292050 scopus 로고    scopus 로고
    • Stationary frame current regulation of PWM inverters with zero steady-state error
    • May
    • D. N. Zmood and D. G. Holmes, "Stationary frame current regulation of PWM inverters with zero steady-state error, " IEEE Trans. Power Electron., vol. 18, no. 3, pp. 814-822, May 2003.
    • (2003) IEEE Trans. Power Electron. , vol.18 , Issue.3 , pp. 814-822
    • Zmood, D.N.1    Holmes, D.G.2
  • 30
    • 0035273190 scopus 로고    scopus 로고
    • Frequency-domain analysis of three-phase linear current regulators
    • DOI 10.1109/28.913727, PII S0093999401021028
    • D. N. Zmood, D. G. Holmes, and G. H. Bode, "Frequency domain analysis of three-phase linear current regulators, " IEEE Trans. Ind. Appl., vol. 37, no. 2, pp. 601-610, Mar. 2001. (Pubitemid 32407296)
    • (2001) IEEE Transactions on Industry Applications , vol.37 , Issue.2 , pp. 601-610
    • Zmood, D.N.1    Holmes, D.G.2    Bode, G.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.