메뉴 건너뛰기




Volumn 45, Issue 3, 2012, Pages 500-506

Investigation of polyelectrolyte for electrochemical detection of uric acid in presence of ascorbic acid

Author keywords

Ascorbic acid; Difference pulse voltammetry; GC electrode; Polyelectrolyte; Uric acid

Indexed keywords

ANODIC CURRENTS; AQUEOUS MEDIA; ASCORBIC ACIDS; CATIONIC POLYELECTROLYTE; CORRELATION COEFFICIENT; CYCLIC VOLTAMETRY; DETECTION LIMITS; DIFFERENTIAL PULSE; ELECTROCHEMICAL DETECTION; GC ELECTRODE; HUMAN URINE; OXIDATION PEAK; OXIDATION POTENTIALS; PEAK CURRENTS; POLY(DIALLYLDIMETHYLAMMONIUM CHLORIDE); PRE-TREATMENT; PULSE VOLTAMMETRY; SIMULTANEOUS DETERMINATIONS; URIC ACIDS; VOLTAMETRY;

EID: 84856761464     PISSN: 02632241     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.measurement.2011.10.022     Document Type: Article
Times cited : (33)

References (45)
  • 1
    • 4243976876 scopus 로고    scopus 로고
    • An elevated serum uric acid (UA) causes kidney damage: Evidence for a novel crystal independent mechanism
    • M. Mazzali, Y.G. Kim, J. Hughes, H.Y. Lan, S. Kivlighn, and R.J. Johnson An elevated serum uric acid (UA) causes kidney damage: evidence for a novel crystal independent mechanism Am. J. Hypertens. 13 2000 36A 37A
    • (2000) Am. J. Hypertens. , vol.13
    • Mazzali, M.1    Kim, Y.G.2    Hughes, J.3    Lan, H.Y.4    Kivlighn, S.5    Johnson, R.J.6
  • 4
    • 0004224444 scopus 로고
    • Sixteenth ed. Lange Medical Publications California pp. 406
    • H.A. Harper Review of Physiological Chemistry Sixteenth ed. 1977 Lange Medical Publications California pp. 406
    • (1977) Review of Physiological Chemistry
    • Harper, H.A.1
  • 5
    • 34548852204 scopus 로고    scopus 로고
    • Determination of serum uric acid using high-performance liquid chromatography (HPLC)/isotope dilution mass spectrometry (ID-MS) as a candidate reference method
    • DOI 10.1016/j.jchromb.2007.07.035, PII S1570023207005454
    • X. Dai, X. Fang, C. Zhang, R. Xu, and B. Xu Determination of serum uric acid using high-performance liquid chromatography (HPLC)/isotope dilution mass spectrometry (ID-MS) as a candidate reference method J. Chromatagr. B 857 2007 287 295 (Pubitemid 47444588)
    • (2007) Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences , vol.857 , Issue.2 , pp. 287-295
    • Dai, X.1    Fang, X.2    Zhang, C.3    Xu, R.4    Xu, B.5
  • 6
    • 34249874326 scopus 로고    scopus 로고
    • Selective uricase biosensor based on polyaniline synthesized in ionic liquid
    • DOI 10.1016/j.snb.2007.01.016, PII S092540050700038X
    • Y. Jiang, A.Y. Wang, and J.Q. Kan Selective uricase biosensor based on polyaniline synthesized in ionic liquid Sens. Actuat. B, Chem. 124 2007 529 534 (Pubitemid 46874042)
    • (2007) Sensors and Actuators, B: Chemical , vol.124 , Issue.2 , pp. 529-534
    • Jiang, Y.1    Wang, A.2    Kan, J.3
  • 7
    • 33846982585 scopus 로고    scopus 로고
    • Simultaneous determination of allantoin, hypoxanthine, xanthine, and uric acid in serum/plasma by CE
    • E. Causse, A. Pradelles, B. Dirat, A. Negre-Salvayre, R. Salvayre, and F. Couderc Simultaneous determination of allantoin, hypoxanthine, xanthine, and uric acid in serum/plasma by CE Electrophoresis 28 2007 381 387
    • (2007) Electrophoresis , vol.28 , pp. 381-387
    • Causse, E.1    Pradelles, A.2    Dirat, B.3    Negre-Salvayre, A.4    Salvayre, R.5    Couderc, F.6
  • 8
    • 38749089039 scopus 로고    scopus 로고
    • Electrochemical behavior of uric acid and epinephrine at an electrochemically activated glassy carbon electrode
    • DOI 10.1016/j.colsurfb.2007.09.012, PII S0927776507003712
    • J.X. Qiao, H.Q. Luo, and N.B. Li Electrochemical behavior of uric acid and epinephrine at an electrochemically activated glassy carbon electrode Colloid Surf., B: Biointerfaces 62 2008 31 35 (Pubitemid 351179234)
    • (2008) Colloids and Surfaces B: Biointerfaces , vol.62 , Issue.1 , pp. 31-35
    • Qiao, J.X.1    Luo, H.Q.2    Li, N.B.3
  • 9
    • 70350146833 scopus 로고    scopus 로고
    • Selective detection of uric acid in the presence of ascorbic acid and dopamine using polymerized luminol film modified glassy carbon electrode
    • S.A. Kumar, H.W. Cheng, and S.M. Chen Selective detection of uric acid in the presence of ascorbic acid and dopamine using polymerized luminol film modified glassy carbon electrode Electroanalysis 21 2009 2281 2286
    • (2009) Electroanalysis , vol.21 , pp. 2281-2286
    • Kumar, S.A.1    Cheng, H.W.2    Chen, S.M.3
  • 10
    • 77953603781 scopus 로고    scopus 로고
    • Simultaneous determination of ascorbic acid, dopamine, and uric acid by differential pulse voltammetry using tiron modified glassy carbon electrode
    • A.A. Ensafi, M. Taei, and T. Khayamian Simultaneous determination of ascorbic acid, dopamine, and uric acid by differential pulse voltammetry using tiron modified glassy carbon electrode Int. J. Electrochem. Sci. 5 2010 116 130
    • (2010) Int. J. Electrochem. Sci. , vol.5 , pp. 116-130
    • Ensafi, A.A.1    Taei, M.2    Khayamian, T.3
  • 11
    • 77649193556 scopus 로고    scopus 로고
    • Simultaneous determination of catecholamines, uric acid and ascorbic acid at physiological levels using poly(N-methylpyrrole)/Pd-nanoclusters sensor
    • N.F. Atta, M.F. ElKady, and A. Galal Simultaneous determination of catecholamines, uric acid and ascorbic acid at physiological levels using poly(N-methylpyrrole)/Pd-nanoclusters sensor Anal. Biochem. 1 2010 78 88
    • (2010) Anal. Biochem. , vol.1 , pp. 78-88
    • Atta, N.F.1    Elkady, M.F.2    Galal, A.3
  • 12
    • 70349478645 scopus 로고    scopus 로고
    • Application of silica gel as an effective modifier for the voltammetric determination of dopamine in the presence of ascorbic acid and uric acid
    • Z. Nasria, and E. Shams Application of silica gel as an effective modifier for the voltammetric determination of dopamine in the presence of ascorbic acid and uric acid Electrochim. Acta 54 2009 7416 7421
    • (2009) Electrochim. Acta , vol.54 , pp. 7416-7421
    • Nasria, Z.1    Shams, E.2
  • 13
    • 53649101492 scopus 로고    scopus 로고
    • Simultaneous voltammetric determination of ascorbic acid, dopamine and uric acid by methylene blue adsorbed on a phosphorylated zirconia-silica composite electrode
    • J. Arguello, V.L. Leidens, H.A. Magosso, R.R. Ramos, and Y. Gushikem Simultaneous voltammetric determination of ascorbic acid, dopamine and uric acid by methylene blue adsorbed on a phosphorylated zirconia-silica composite electrode Electrochim. Acta 54 2008 560 565
    • (2008) Electrochim. Acta , vol.54 , pp. 560-565
    • Arguello, J.1    Leidens, V.L.2    Magosso, H.A.3    Ramos, R.R.4    Gushikem, Y.5
  • 14
    • 70349446315 scopus 로고    scopus 로고
    • Electropolymerized film of functionalized thiadiazole on glassy carbon electrode for the simultaneous determination of ascorbic acid, dopamine and uric acid
    • P. Kalimuthu, S.A. John, H. Tang, G. Hu, S. Jiang, and X. Liu Electropolymerized film of functionalized thiadiazole on glassy carbon electrode for the simultaneous determination of ascorbic acid, dopamine and uric acid Bioelectrochemistry 77 2009 13 18
    • (2009) Bioelectrochemistry , vol.77 , pp. 13-18
    • Kalimuthu, P.1    John, S.A.2    Tang, H.3    Hu, G.4    Jiang, S.5    Liu, X.6
  • 15
    • 79952007428 scopus 로고    scopus 로고
    • Simultaneous voltammetric determination of ascorbic acid and uric acid using a Nafion/multi-wall carbon nanotubes composite film-modified electrode
    • 10.1007/s10008-010-1088-7
    • G. Li, S. Yang, L. Qu, R. Yang, and J. Li Simultaneous voltammetric determination of ascorbic acid and uric acid using a Nafion/multi-wall carbon nanotubes composite film-modified electrode J. Solid State Electrochem. 2010 10.1007/s10008-010-1088-7
    • (2010) J. Solid State Electrochem.
    • Li, G.1    Yang, S.2    Qu, L.3    Yang, R.4    Li, J.5
  • 16
    • 57849162004 scopus 로고    scopus 로고
    • Simultaneous determination of dopamine ascorbic acid and uric acid on ordered mesoporous carbon/Nafion composite film
    • D. Zheng, J. Ye, L. Zhou, Y. Zhang, and C. Yu Simultaneous determination of dopamine ascorbic acid and uric acid on ordered mesoporous carbon/Nafion composite film J. Electroanal. Chem. 625 2009 82 87
    • (2009) J. Electroanal. Chem. , vol.625 , pp. 82-87
    • Zheng, D.1    Ye, J.2    Zhou, L.3    Zhang, Y.4    Yu, C.5
  • 17
    • 44649192923 scopus 로고    scopus 로고
    • Simultaneous determination of dopamine, ascorbic acid and uric acid at poly(Evans Blue) modified glassy carbon electrode
    • L. Lin, J. Chen, H. Yao, Y. Chen, Y. Zheng, and X. Lin Simultaneous determination of dopamine, ascorbic acid and uric acid at poly(Evans Blue) modified glassy carbon electrode Bioelectrochemistry 73 2008 11 17
    • (2008) Bioelectrochemistry , vol.73 , pp. 11-17
    • Lin, L.1    Chen, J.2    Yao, H.3    Chen, Y.4    Zheng, Y.5    Lin, X.6
  • 18
    • 33846585113 scopus 로고    scopus 로고
    • Simultaneous detection of ascorbic acid, uric acid and homovanillic acid at copper modified electrode
    • DOI 10.1016/j.electacta.2006.09.032, PII S0013468606010012
    • T. Selvaraju, and R. Ramaraj Simultaneous detection of ascorbic acid, uric acid and homovanillic acid at copper modified electrode Electrochimica. Acta 52 2007 2998 3005 (Pubitemid 46176871)
    • (2007) Electrochimica Acta , vol.52 , Issue.9 , pp. 2998-3005
    • Selvaraju, T.1    Ramaraj, R.2
  • 19
    • 33947609178 scopus 로고    scopus 로고
    • Polycation coating poly(dimethylsiloxane) capillary electrophoresis microchip for rapid separation of ascorbic acid and uric acid
    • DOI 10.1007/s00216-007-1173-7, Metal Vapor Generation
    • Q.L. Zhang, J.J. Xu, H.Z. Lian, X.Y. Li, and H.Y. Chen Polycation coating poly(dimethyl siloxane) capillary electrophoresis microchip for rapid separation of ascorbic acid and uric acid Anal. Bioanal. Chem. 387 2007 2699 2704 (Pubitemid 46479932)
    • (2007) Analytical and Bioanalytical Chemistry , vol.387 , Issue.8 , pp. 2699-2704
    • Zhang, Q.L.1    Xu, J.J.2    Lian, H.Z.3    Li, X.Y.4    Chen, H.Y.5
  • 20
    • 78650174891 scopus 로고    scopus 로고
    • Poly(3,4-ethylene-dioxythiophene) electrode for the selective determination of dopamine in presence of sodium dodecyl sulfate
    • N.F. Atta, A. Galal, and R.A. Ahmed Poly(3,4-ethylene-dioxythiophene) electrode for the selective determination of dopamine in presence of sodium dodecyl sulfate Bioelectrochemistry 80 2010 132 141
    • (2010) Bioelectrochemistry , vol.80 , pp. 132-141
    • Atta, N.F.1    Galal, A.2    Ahmed, R.A.3
  • 21
  • 22
    • 77952292211 scopus 로고    scopus 로고
    • Simultaneous determination of uric acid and ascorbic acid at the film of chitosan incorporating cetylpyridine bromide modified glassy carbon electrode
    • X. Cao, Y. Xu, L. Luo, Y. Ding, and Y. Zhang Simultaneous determination of uric acid and ascorbic acid at the film of chitosan incorporating cetylpyridine bromide modified glassy carbon electrode J. Solid State Electrohem. 14 2010 829 834
    • (2010) J. Solid State Electrohem. , vol.14 , pp. 829-834
    • Cao, X.1    Xu, Y.2    Luo, L.3    Ding, Y.4    Zhang, Y.5
  • 23
    • 70149097345 scopus 로고    scopus 로고
    • Simultaneous determination of dopamine, uric acid and ascorbic acid with CTAB modified carbon paste electrode
    • S.S. Shankar, B.E.K. Swamy, U. Chandra, J.G. Manjunatha, and B.S. Sherigara Simultaneous determination of dopamine, uric acid and ascorbic acid with CTAB modified carbon paste electrode Int. J. Electrochem. Sci. 4 2009 592 601
    • (2009) Int. J. Electrochem. Sci. , vol.4 , pp. 592-601
    • Shankar, S.S.1    Swamy, B.E.K.2    Chandra, U.3    Manjunatha, J.G.4    Sherigara, B.S.5
  • 24
    • 0032145064 scopus 로고    scopus 로고
    • A selective voltammetric method for uric acid detection at Nafion®-coated carbon paste electrodes
    • J.M. Zen, and C.T. Hsu A selective voltammetric method for uric acid detection at Nafion®-coated carbon paste electrodes Talanta 46 1998 1363 1369
    • (1998) Talanta , vol.46 , pp. 1363-1369
    • Zen, J.M.1    Hsu, C.T.2
  • 26
    • 11744290819 scopus 로고    scopus 로고
    • Deposition of polyaniline on micro-contact printed self-assembled monolayers of ω-functionalized alkanethiols
    • C.N. Sayre, and D.M. Collard Deposition of polyaniline on micro-contact printed self-assembled monolayers of functionalized alkanethiols J. Mater. Chem. 7 1997 909 912 (Pubitemid 127731231)
    • (1997) Journal of Materials Chemistry , vol.7 , Issue.6 , pp. 909-912
    • Sayre, C.N.1
  • 27
    • 84856725119 scopus 로고    scopus 로고
    • Synthesis, optical and electroluminescent properties of novel polyfluorene/carbazole-based conjugated polyelectrolytes and their precursors
    • W. Cao, H. Dong, F. Huang, H. Shen, and Y. Cao Synthesis, optical and electroluminescent properties of novel polyfluorene/carbazole-based conjugated polyelectrolytes and their precursors Front. Optoelectron. China 1 2008 299 304
    • (2008) Front. Optoelectron. China , vol.1 , pp. 299-304
    • Cao, W.1    Dong, H.2    Huang, F.3    Shen, H.4    Cao, Y.5
  • 28
    • 67649222416 scopus 로고    scopus 로고
    • Polyaniline-polyelectrolyte-gold(0) ternary nanocomposites: Synthesis and electrochemical properties
    • S. Prakash, C.R.K. Rao, and M. Vijayan Polyaniline-polyelectrolyte- gold(0) ternary nanocomposites: synthesis and electrochemical properties Electrochim. Acta 54 2009 5919 5927
    • (2009) Electrochim. Acta , vol.54 , pp. 5919-5927
    • Prakash, S.1    Rao, C.R.K.2    Vijayan, M.3
  • 30
    • 33644683512 scopus 로고    scopus 로고
    • Determination of dopamine in the presence of ascorbic acid by poly(styrene sulfonic acid) sodium salt/single-wall carbon nanotube film modified glassy carbon electrode
    • DOI 10.1016/j.ab.2006.01.002, PII S0003269706000054
    • Y. Zhang, Y. Cai, and S. Su Determination of dopamine in the presence of ascorbic acid by poly(styrene sulfonic acid) sodium salt/single-wall carbon nanotube film modified glassy carbon electrode Anal. Biochem. 350 2006 285 291 (Pubitemid 43332830)
    • (2006) Analytical Biochemistry , vol.350 , Issue.2 , pp. 285-291
    • Zhang, Y.1    Cai, Y.2    Su, S.3
  • 31
    • 33751082421 scopus 로고    scopus 로고
    • Polyelectrolyte bridging interactions between charged macromolecules
    • DOI 10.1016/j.cocis.2006.08.001, PII S1359029406000410
    • R. Podgornik, and M. Licer Polyelectrolyte bridging interactions between charged macro molecules Curr. Opin. Colloid Interface Sci. 11 2006 273 279 (Pubitemid 44765280)
    • (2006) Current Opinion in Colloid and Interface Science , vol.11 , Issue.5 , pp. 273-279
    • Podgornik, R.1    Licer, M.2
  • 32
    • 0017969847 scopus 로고
    • Oxidation of L-ascorbic acid on a gold electrode
    • DOI 10.1016/0013-4686(78)87040-6
    • M. Reudo, A. Aldaz, and F.S. Burgos Oxidation of L-ascorbic acid on a gold electrode Electrochim. Acta 23 1978 419 424 (Pubitemid 8613398)
    • (1978) Electrochimica Acta , vol.23 , Issue.5 , pp. 419-424
    • Rueda, M.1    Aldaz, A.2    Sanchez-Burgos, F.3
  • 33
    • 0035083134 scopus 로고    scopus 로고
    • Electroanalytical applications of cationic self-assembled monolayers: Square-wave voltammetric determination of dopamine and ascorbate
    • PII S030245980000129X
    • C.R. Raj, K. Tokuda, and T. Oshaka Electroanalytical applications of cationic self-assembled monolayers: square-wave voltammetric determination of dopamine and ascorbate Bioelectrochemistry 53 2001 183 191 (Pubitemid 32243985)
    • (2001) Bioelectrochemistry , vol.53 , Issue.2 , pp. 183-191
    • Raj, C.R.1    Tokuda, K.2    Ohsaka, T.3
  • 34
    • 10644270095 scopus 로고    scopus 로고
    • Simultaneous electrochemical detection of uric acid and ascorbic acid at a poly(N,N-dimethylaniline) film-coated GC electrode
    • P.R. Roy, T. Okajima, and T. Oshaka Simultaneous electrochemical detection of uric acid and ascorbic acid at a poly(N,N-dimethylaniline) film-coated GC electrode J. Electroanal. Chem. 561 2004 75 82
    • (2004) J. Electroanal. Chem. , vol.561 , pp. 75-82
    • Roy, P.R.1    Okajima, T.2    Oshaka, T.3
  • 35
    • 0000486126 scopus 로고
    • Cyclic voltammetric analysis of ferrocene alkanethiol monolayer electrode kinetics based on marcus theory
    • L. Tender, M.T. Carter, and R.W. Murray Cyclic voltammetric analysis of ferrocene alkanethiol monolayer electrode kinetics based on marcus theory Anal. Chem. 66 1994 3173 3181
    • (1994) Anal. Chem. , vol.66 , pp. 3173-3181
    • Tender, L.1    Carter, M.T.2    Murray, R.W.3
  • 36
    • 18144429898 scopus 로고    scopus 로고
    • Simultaneous determination of uric acid and ascorbic acid using glassy carbon electrodes in acetate buffer solution
    • DOI 10.1016/j.jelechem.2005.02.012, PII S0022072805001075
    • S.A. John Simultaneous determination of uric acid and ascorbic acid using glassy carbon electrodes in acetate buffer solution J. Electroanal. Chem. 579 2005 249 256 (Pubitemid 40612498)
    • (2005) Journal of Electroanalytical Chemistry , vol.579 , Issue.2 , pp. 249-256
    • John, S.A.1
  • 37
    • 0037413684 scopus 로고    scopus 로고
    • Carbon nanotube-intercalated graphite electrodes for simultaneous determination of dopamine and serotonin in the presence of ascorbic acid
    • Z. Wang, Q. Liang, Y. Wang, and G. Luo Carbon nanotube-intercalated graphite electrodes for simultaneous determination of dopamine and serotonin in the presence of ascorbic acid J. Electroanal. Chem. 540 2003 129 134
    • (2003) J. Electroanal. Chem. , vol.540 , pp. 129-134
    • Wang, Z.1    Liang, Q.2    Wang, Y.3    Luo, G.4
  • 38
    • 0030778891 scopus 로고    scopus 로고
    • Catalytic oxidation of uric acid at the polyglycine chemically modified electrode and its trace determination
    • A.M. Yu, H.L. Zhang, and H.Y. Chen Catalytic oxidation of uric acid at the polyglycine chemically modified electrode and its trace determination Analyst 122 1997 839 841
    • (1997) Analyst , vol.122 , pp. 839-841
    • Yu, A.M.1    Zhang, H.L.2    Chen, H.Y.3
  • 39
    • 0032637583 scopus 로고    scopus 로고
    • In situ STM study of self-assembled mercaptopropionic acid monolayers for electrochemical detection of dopamine
    • M.J. Giz, B. Duong, and N.J. Tao In situ STM study of self-assembled mercaptopropionic acid monolayers for electrochemical detection of dopamine J. Electroanal. Chem. 465 1999 72 79
    • (1999) J. Electroanal. Chem. , vol.465 , pp. 72-79
    • Giz, M.J.1    Duong, B.2    Tao, N.J.3
  • 40
    • 29744447770 scopus 로고    scopus 로고
    • Determination of uric acid in the presence of ascorbic acid using poly(3,4-ethylenedioxythiophene)-modified electrodes
    • S.S. Kumar, J. Mathiyarasu, K.L.N. Phani, Y.K. Jain, and V. Yegnaraman Determination of uric acid in the presence of ascorbic acid using poly(3,4-ethylenedioxythiophene)-modified electrodes Electroanalysis 17 2005 2281 2286
    • (2005) Electroanalysis , vol.17 , pp. 2281-2286
    • Kumar, S.S.1    Mathiyarasu, J.2    Phani, K.L.N.3    Jain, Y.K.4    Yegnaraman, V.5
  • 41
    • 42749090016 scopus 로고    scopus 로고
    • Electrochemical determination of uric acid at ordered mesoporous carbon functionalized with ferrocenecarboxylic acid-modified electrode
    • J.C. Ndamanisha, and L. Guo Electrochemical determination of uric acid at ordered mesoporous carbon functionalized with ferrocenecarboxylic acid-modified electrode Biosens. Bioelectron. 23 2008 1680 1685
    • (2008) Biosens. Bioelectron. , vol.23 , pp. 1680-1685
    • Ndamanisha, J.C.1    Guo, L.2
  • 43
    • 77949273266 scopus 로고    scopus 로고
    • A highly slective & sensitive dopamine & uric acid biosensor fabricated withfunctionalised ordered mesoporous carbon and hydrophobic ionic liquid
    • J. Dong, Y. Hu, S. Zhu, and J. Xu A highly slective & sensitive dopamine & uric acid biosensor fabricated withfunctionalised ordered mesoporous carbon and hydrophobic ionic liquid Anal. Bioanaly. Chem. 396 2010 1755 1762
    • (2010) Anal. Bioanaly. Chem. , vol.396 , pp. 1755-1762
    • Dong, J.1    Hu, Y.2    Zhu, S.3    Xu, J.4
  • 44
    • 0345278029 scopus 로고    scopus 로고
    • Normal reference laboratory values
    • A. Kratz, and K.B. Lewandrowski Normal reference laboratory values New Engl. J. Med. 339 1998 1036 1042
    • (1998) New Engl. J. Med. , vol.339 , pp. 1036-1042
    • Kratz, A.1    Lewandrowski, K.B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.