-
1
-
-
1542399631
-
Respiratory gating for 3-dimensional PET of the thorax: Feasibility and initial results
-
L. Boucher, S. Rodrigue, R. Lecomte, and F. Benard, "Respiratory gating for 3-Dimensional PET of the thorax: Feasibility and initial results," J. Nucl. Med., vol. 45, no. 2, pp. 214-219, Feb. 2004. (Pubitemid 47618639)
-
(2004)
Journal of Nuclear Medicine
, vol.45
, Issue.2
, pp. 214-219
-
-
Boucher, L.1
Rodrigue, S.2
Lecomte, R.3
Benard, F.4
-
2
-
-
0037783428
-
18F]FDG uptake in PET
-
D. Visvikis, D. C. Costa, I. Croasdale, A. H. R. Lonn, J. Bomanji, S. Gacinovic, and P. J. Ell, "CT-based attenuation correction in the calculation of semi-quantitative indices of uptake in PET," Eur. J. Nucl. Med. Mol. Imag., vol. 30, no. 3, pp. 344-53, Mar. 2003. (Pubitemid 36692858)
-
(2003)
European Journal of Nuclear Medicine and Molecular Imaging
, vol.30
, Issue.3
, pp. 344-353
-
-
Visvikis, D.1
Costa, D.C.2
Croasdale, I.3
Lonn, A.H.R.4
Bomanji, J.5
Gacinovic, S.6
Ell, P.J.7
-
3
-
-
4544221611
-
The CT motion quantitation of lung lesions and its impact on PET-measured SUVs
-
Y. E. Erdi, S. A. Nehmeh, T. Pan, A. Pevsner, K. E. Rosenzweig, G. Mageras, E. D. Yorke, H. Schoder, W. Hsiao, O. D. Squire, P. Vernon, J. B. Ashman, H. Mostafavi, S. M. Larson, and J. L. Humm, "The CT motion quantitation of lung lesions and its impact on PET-Measured SUVs," J. Nucl. Med., vol. 45, no. 8, pp. 1287-1292, Aug. 2004. (Pubitemid 47618524)
-
(2004)
Journal of Nuclear Medicine
, vol.45
, Issue.8
, pp. 1287-1292
-
-
Erdi, Y.E.1
Nehmeh, S.A.2
Pan, T.3
Pevsner, A.4
Rosenzweig, K.E.5
Mageras, G.6
Yorke, E.D.7
Schoder, H.8
Hsiao, W.9
Squire, O.D.10
Vernon, P.11
Ashman, J.B.12
Mostafavi, H.13
Larson, S.M.14
Humm, J.L.15
-
4
-
-
18344390040
-
Effect of respiratory gating on reducing lung motion artifacts in PET imaging of lung cancer
-
S. A. Nehmeh, Y. E. Erdi, C. C. Ling, K. E. Rosenzweig, O. D. Squire, L. E. Braban, E. Ford, K. Sidhu, G. S. Mageras, S. M. Larson, and J. L. Humm, "Effect of respiratory gating on reducing lung motion artifacts in PET imaging of lung cancer," Med. Phys., vol. 29, no. 3, p. 366, 2002.
-
(2002)
Med. Phys.
, vol.29
, Issue.3
, pp. 366
-
-
Nehmeh, S.A.1
Erdi, Y.E.2
Ling, C.C.3
Rosenzweig, K.E.4
Squire, O.D.5
Braban, L.E.6
Ford, E.7
Sidhu, K.8
Mageras, G.S.9
Larson, S.M.10
Humm, J.L.11
-
5
-
-
33750932365
-
Compensating for patient respiration in PET/CT imaging with the registered and summed phases (RASP) procedure
-
1625115, 2006 3rd IEEE International Symposium on Biomedical Imaging: From Nano to Macro - Proceedings
-
P. Kinahan, L. MacDonald, L. Ng, A. Alessio, P. Segars, B. Tsui, and S. Pathak, "Compensating for patient respiration in PET/CT imaging with the registered and summed phases (RASP) procedure," in Proc. 3rd IEEE Int. Symp. Biomed. Imag.: Nano Macro, Apr. 2006, pp. 1104-1107. (Pubitemid 44732515)
-
(2006)
2006 3rd IEEE International Symposium on Biomedical Imaging: From Nano to Macro - Proceedings
, vol.2006
, pp. 1104-1107
-
-
Kindhan, P.1
MacDonald, L.2
Ng, L.3
Alessio, A.4
Segars, P.5
Tsui, B.6
Pathak, S.7
-
6
-
-
33645686564
-
Lung motion correction on respiratory gated 3-D PET/CT images
-
Apr.
-
M. Dawood, N. Lang, X. Jiang, and K. P. Schafers, "Lung motion correction on respiratory gated 3-D PET/CT images," IEEE Trans. Med. Imag., vol. 25, no. 4, pp. 476-485, Apr. 2006.
-
(2006)
IEEE Trans. Med. Imag.
, vol.25
, Issue.4
, pp. 476-485
-
-
Dawood, M.1
Lang, N.2
Jiang, X.3
Schafers, K.P.4
-
7
-
-
34247281725
-
Respiratory motion correction for PET oncology applications using affine transformation of list mode data
-
DOI 10.1088/0031-9155/52/1/009, PII S0031915507302376, 009
-
F. Lamare, T. Cresson, J. Savean, C. C. L. Rest, A. J. Reader, and D. Visvikis, "Respiratory motion correction for PET oncology applications using affine transformation of list mode data," Phys. Med. Biol., vol. 52, no. 1, pp. 121-140, 2007. (Pubitemid 46646270)
-
(2007)
Physics in Medicine and Biology
, vol.52
, Issue.1
, pp. 121-140
-
-
Lamare, F.1
Cresson, T.2
Savean, J.3
Cheze Le Rest, C.4
Reader, A.J.5
Visvikis, D.6
-
8
-
-
22244488754
-
Rigid-body transformation of list-mode projection data for respiratory motion correction in cardiac PET
-
DOI 10.1088/0031-9155/50/14/008
-
L. Livieratos, L. Stegger, P. M. Bloomfield, K. Schafers, D. L. Bailey, and P. G. Camici, "Rigid-body transformation of list-mode projection data for respiratory motion correction in cardiac PET," Phys. Med. Biol., vol. 50, no. 14, pp. 3313-3322, Jul. 2005. (Pubitemid 40991691)
-
(2005)
Physics in Medicine and Biology
, vol.50
, Issue.14
, pp. 3313-3322
-
-
Livieratos, L.1
Stegger, L.2
Bloomfield, P.M.3
Schafers, K.4
Bailey, D.L.5
Camici, P.G.6
-
9
-
-
33746512521
-
A motion-incorporated reconstruction method for gated PET studies
-
DOI 10.1088/0031-9155/51/15/012, PII S0031915506183074, 012
-
F. Qiao, T. Pan, J. W. Clark, and O. R. Mawlawi, "A motion-incorporated reconstruction method for gated PET studies," Phys. Med. Biol., vol. 51, pp. 3769-3783, Aug. 2006. (Pubitemid 44131364)
-
(2006)
Physics in Medicine and Biology
, vol.51
, Issue.15
, pp. 3769-3783
-
-
Qiao, F.1
Pan, T.2
Clark Jr., J.W.3
Mawlawi, O.R.4
-
10
-
-
36048972941
-
List-mode-based reconstruction for respiratory motion correction in PET using non-rigid body transformations
-
DOI 10.1088/0031-9155/52/17/006, PII S0031915507461516
-
F. Lamare, M. J. L. Carbayo, T. Cresson, G. Kontaxakis, A. Santos, C. C. L. Rest, A. J. Reader, and D. Visvikis, "List-mode-based reconstruction for respiratory motion correction in PET using non-rigid body transformations, " Phys. Med. Biol., vol. 52, no. 17, pp. 5187-5204, Sep. 2007. (Pubitemid 350153383)
-
(2007)
Physics in Medicine and Biology
, vol.52
, Issue.17
, pp. 5187-5204
-
-
Lamare, F.1
Ledesma Carbayo, M.J.2
Cresson, T.3
Kontaxakis, G.4
Santos, A.5
Le Rest, C.C.6
Reader, A.J.7
Visvikis, D.8
-
11
-
-
85032751333
-
Super-resolution image reconstruction
-
M. G. Kang and S. Chaudhuri, "Super-resolution image reconstruction," IEEE Signal Process. Mag., vol. 20, no. 3, pp. 19-20, 2003.
-
(2003)
IEEE Signal Process. Mag.
, vol.20
, Issue.3
, pp. 19-20
-
-
Kang, M.G.1
Chaudhuri, S.2
-
12
-
-
0021372397
-
Real-time data rebinning in PET to obtain uniformly sampled projections
-
A. Dagher and C. J. Thompson, "Real-time data rebinning in PET to obtain uniformly sampled projections," IEEE Trans. Nucl. Sci., vol. 32, no. 1, pp. 811-817, Feb. 1985. (Pubitemid 15522229)
-
(1984)
IEEE Transactions on Nuclear Science
, vol.NS-32
, Issue.1
, pp. 811-817
-
-
Dagher, A.1
Thompson, C.J.2
-
13
-
-
0026917273
-
Superresolved tomography by convex projections and detector motion
-
Sep.
-
M. N. Wernick and C. T. Chen, "Superresolved tomography by convex projections and detector motion," J. Opt. Soc. Am. A, Optics Image Sci., vol. 9, no. 9, pp. 1547-1553, Sep. 1992.
-
(1992)
J. Opt. Soc. Am. A, Optics Image Sci.
, vol.9
, Issue.9
, pp. 1547-1553
-
-
Wernick, M.N.1
Chen, C.T.2
-
14
-
-
31644450249
-
Super-resolution in PET imaging
-
DOI 10.1109/TMI.2005.861705
-
J. Kennedy, O. Israel, A. Frenkel, R. Bar-Shalom, and H. Azhari, "Super-resolution in PET imaging," IEEE Trans. Med. Imag., vol. 25, no. 2, pp. 137-147, Feb. 2006. (Pubitemid 43172568)
-
(2006)
IEEE Transactions on Medical Imaging
, vol.25
, Issue.2
, pp. 137-147
-
-
Kennedy, J.A.1
Israel, O.2
Frenkel, A.3
Bar-Shalom, R.4
Azhari, H.5
-
15
-
-
33846653875
-
Improved image fusion in PET/CT using hybrid image reconstruction and super-resolution
-
J. A. Kennedy, O. Israel, A. Frenkel, R. Bar-Shalom, and H. Azhari, "Improved image fusion in PET/CT using hybrid image reconstruction and super-resolution," Int. J. Biomed. Imag., 2007.
-
(2007)
Int. J. Biomed. Imag.
-
-
Kennedy, J.A.1
Israel, O.2
Frenkel, A.3
Bar-Shalom, R.4
Azhari, H.5
-
16
-
-
56749169671
-
Optimization of super-resolution processing using incomplete image sets in PET imaging
-
G. Chang, T. Pan, J. W. Clark, and O. R. Mawlawi, "Optimization of super-resolution processing using incomplete image sets in PET imaging," Med. Phys., vol. 35, no. 12, p. 5748, 2008.
-
(2008)
Med. Phys.
, vol.35
, Issue.12
, pp. 5748
-
-
Chang, G.1
Pan, T.2
Clark, J.W.3
Mawlawi, O.R.4
-
17
-
-
63849305140
-
Comparison between two super-resolution implementations in PET imaging
-
G. Chang, T. Pan, F. Qiao, J. W. Clark, and O. R. Mawlawi, "Comparison between two super-resolution implementations in PET imaging," Med. Phys., vol. 36, no. 4, p. 1370, 2009.
-
(2009)
Med. Phys.
, vol.36
, Issue.4
, pp. 1370
-
-
Chang, G.1
Pan, T.2
Qiao, F.3
Clark, J.W.4
Mawlawi, O.R.5
-
18
-
-
0026359271
-
Improving resolution by image registration
-
DOI 10.1016/1049-9652(91)90045-L
-
M. Irani and S. Peleg, "Improving resolution by image registration," Graphical Models Image Process. (CVGIP), vol. 53, no. 3, pp. 231-239, 1991. (Pubitemid 21651453)
-
(1991)
CVGIP. Graphical models and image processing
, vol.53
, Issue.3
, pp. 231-239
-
-
Irani Michal1
Peleg Shmuel2
-
19
-
-
0024758573
-
High-resolution image recovery from imageplane arrays, using convex projections
-
Nov.
-
H. Stark and P. Oskoui, "High-resolution image recovery from imageplane arrays, using convex projections," Opt. Soc. Am., J. A: Opt. Image Sci., vol. 6, pp. 1715-1726, Nov. 1989.
-
(1989)
Opt. Soc. Am., J. A: Opt. Image Sci.
, vol.6
, pp. 1715-1726
-
-
Stark, H.1
Oskoui, P.2
-
20
-
-
48349091999
-
Respiratory motion correction in PET with super-resolution techniques and non-rigid registration
-
J. L. Rubio-Guivernau, M. J. Ledesma-Carbayo, F. Lamare, J. E. Ortuno, P. Guerra, D. Visvikis, A. Santos, and G. Kontaxakis, "Respiratory motion correction in PET with super-resolution techniques and non-rigid registration," in IEEE Nucl. Sci. Symp. Conf. Rec., 2007, vol. 5, pp. 3560-3563.
-
(2007)
IEEE Nucl. Sci. Symp. Conf. Rec.
, vol.5
, pp. 3560-3563
-
-
Rubio-Guivernau, J.L.1
Ledesma-Carbayo, M.J.2
Lamare, F.3
Ortuno, J.E.4
Guerra, P.5
Visvikis, D.6
Santos, A.7
Kontaxakis, G.8
-
21
-
-
0028427322
-
A Bayesian approach to image expansion for improved definition
-
May
-
R. Schultz and R. L. Stevenson, "A Bayesian approach to image expansion for improved definition," IEEE Trans. Image Process., vol. 3, no. 3, pp. 233-242, May 1994.
-
(1994)
IEEE Trans. Image Process.
, vol.3
, Issue.3
, pp. 233-242
-
-
Schultz, R.1
Stevenson, R.L.2
-
22
-
-
84856711854
-
Bayesian image and video enhancement using a non-Gaussian prior
-
K. Barner and G. Arce, Eds. Boca Raton, FL: CRC
-
R. Schultz and R. L. Stevenson, "Bayesian image and video enhancement using a non-Gaussian prior," in Nonlinear Signal ands Image Processing: Theory, Methods and Applications, K. Barner and G. Arce, Eds. Boca Raton, FL: CRC, 2004, pp. 295-332.
-
(2004)
Nonlinear Signal Ands Image Processing: Theory, Methods and Applications
, pp. 295-332
-
-
Schultz, R.1
Stevenson, R.L.2
-
23
-
-
33750956734
-
Super-resolution enhancement of text image sequence
-
D. P. Capel and A. Zisserman, "Super-resolution enhancement of text image sequence," in Int. Conf. Pattern Recognit., 2000, pp. 600-605.
-
(2000)
Int. Conf. Pattern Recognit.
, pp. 600-605
-
-
Capel, D.P.1
Zisserman, A.2
-
24
-
-
0242468065
-
Fast parametric elastic image registration
-
Nov.
-
J. Kybic and M. Unser, "Fast parametric elastic image registration," IEEE Trans. Image Process., vol. 12, no. 11, pp. 1427-1442, Nov. 2003.
-
(2003)
IEEE Trans. Image Process.
, vol.12
, Issue.11
, pp. 1427-1442
-
-
Kybic, J.1
Unser, M.2
-
25
-
-
33645284910
-
Validation of a monte carlo simulation of the Philips Allegro/GEMINI PET systems using gate
-
Feb.
-
F. Lamare, A. Turzo, Y. Bizais, C. C. L. Rest, and D. Visvikis, "Validation of a Monte Carlo simulation of the Philips Allegro/GEMINI PET systems using gate," Phys. Med. Biol., vol. 51, no. 4, pp. 943-962, Feb. 2006.
-
(2006)
Phys. Med. Biol.
, vol.51
, Issue.4
, pp. 943-962
-
-
Lamare, F.1
Turzo, A.2
Bizais, Y.3
Rest, C.C.L.4
Visvikis, D.5
-
26
-
-
84903493258
-
IEC emission phantom appendix performance evaluation of positron emission tomographs Med
-
K. Jordan, IEC emission phantom appendix performance evaluation of positron emission tomographs Med. Public Health Res. Program Eur. Commun., 1990.
-
(1990)
Public Health Res. Program Eur. Commun.
-
-
Jordan, K.1
-
27
-
-
0035246235
-
Modeling respiratory mechanics in the MCAT and spline-based MCAT phantoms
-
DOI 10.1109/23.910837
-
W. Segars, D. Lalush, and B. Tsui, "Modeling respiratory mechanics in the MCAT and spline-based MCAT phantoms," IEEE Trans. Nucl. Sci., vol. 48, no. 1, pp. 89-97, Feb. 2001. (Pubitemid 32325607)
-
(2001)
IEEE Transactions on Nuclear Science
, vol.48
, Issue.1
, pp. 89-97
-
-
Segars, W.P.1
Lalush, D.S.2
Tsui, B.M.W.3
-
28
-
-
0036624497
-
One-pass list-mode EM algorithm for high-resolution 3-D PET image reconstruction into large arrays
-
DOI 10.1109/TNS.2002.1039550, PII S0018949902061889
-
A. Reader, S. Ally, F. Bakatselos, R. Manavaki, R. Walledge, A. Jeavons, P. Julyan, S. Zhao, D. Hastings, and J. Zweit, "One-pass list-mode EM algorithm for high-resolution 3-D PET image reconstruction into large arrays," IEEE Trans. Nucl. Sci., vol. 49, no. 3, pp. 693-699, Jun. 2002. (Pubitemid 35311888)
-
(2002)
IEEE Transactions on Nuclear Science
, vol.49
, Issue.3
, pp. 693-699
-
-
Reader, A.J.1
Ally, S.2
Bakatselos, F.3
Manavaki, R.4
Walledge, R.J.5
Jeavons, A.P.6
Julyan, P.J.7
Zhao, S.8
Hastings, D.L.9
Zweit, J.10
-
29
-
-
70450174223
-
Incorporating patient-specific variability in the simulation of realistic whole-body[18F] distributions for oncology applications
-
Dec.
-
A. L. Maitre, W. Segars, S. Marache, A. Reilhac, M. Hatt, S. Tomei, C. Lartizien, and D. Visvikis, "Incorporating patient-specific variability in the simulation of realistic whole-body[18F] distributions for oncology applications," Proc. IEEE, vol. 97, no. 12, pp. 2026-2038, Dec. 2009.
-
(2009)
Proc. IEEE
, vol.97
, Issue.12
, pp. 2026-2038
-
-
Maitre, A.L.1
Segars, W.2
Marache, S.3
Reilhac, A.4
Hatt, M.5
Tomei, S.6
Lartizien, C.7
Visvikis, D.8
|