메뉴 건너뛰기




Volumn 22, Issue 2, 2012, Pages 111-117

Design, biomechanical study, and clinical application of a new pterygo-shaped titanium mesh cage

Author keywords

Anterior decompression; Biomechanics; Cervical vertebra; Internal fixators; New pterygo shaped titanium mesh cage

Indexed keywords

TITANIUM;

EID: 84856619776     PISSN: 16338065     EISSN: 14321068     Source Type: Journal    
DOI: 10.1007/s00590-011-0817-7     Document Type: Article
Times cited : (4)

References (24)
  • 1
    • 0001473186 scopus 로고
    • Stabilization of the cervical spine by anterior fusion
    • 1:STN:280:DyaF3c3hvFOhuw%3D%3D
    • RW Bailey CE Badgley 1960 Stabilization of the cervical spine by anterior fusion Am J Orthop 42-A 565 594 1:STN:280:DyaF3c3hvFOhuw%3D%3D
    • (1960) Am J Orthop , vol.42 , pp. 565-594
    • Bailey, R.W.1    Badgley, C.E.2
  • 2
    • 84924638714 scopus 로고
    • The treatment of cervical spine disorders by anterior removal of the intervertebral disc and interbody fusion
    • GW Smith RA Robinson 1958 The treatment of cervical spine disorders by anterior removal of the intervertebral disc and interbody fusion J Bone Joint Surg (Am) 40 607 624
    • (1958) J Bone Joint Surg (Am) , vol.40 , pp. 607-624
    • Smith, G.W.1    Robinson, R.A.2
  • 3
    • 70449235124 scopus 로고
    • The anterior approach for removal of ruptured discs
    • 13599052 10.3171/jns.1958.15.6.0602 1:STN:280:DyaG1M%2FivVCmtg%3D%3D
    • RB Cloward 1958 The anterior approach for removal of ruptured discs J Neurosurg 15 602 617 13599052 10.3171/jns.1958.15.6.0602 1:STN:280: DyaG1M%2FivVCmtg%3D%3D
    • (1958) J Neurosurg , vol.15 , pp. 602-617
    • Cloward, R.B.1
  • 4
    • 0018751586 scopus 로고
    • Transoral cervical corpectomy with the aid of the microscope
    • DOI 10.1097/00007632-197905000-00006
    • M Salcman J Jamaris H Leveque, et al. 1979 Transoral cervical corpectomy with the aid of the microscope Spine 4 209 212 472893 10.1097/00007632- 197905000-00006 1:STN:280:DyaE1M3kvFWhtA%3D%3D (Pubitemid 9198203)
    • (1979) Spine , vol.4 , Issue.3 , pp. 209-212
    • Salcman, M.1    Jamaris, J.2    Leveque, H.3    Ducker, T.B.4
  • 5
    • 0033168319 scopus 로고    scopus 로고
    • Anterior interbody fusion of the cervical spine with coralline hydroxyapatite
    • DOI 10.1097/00007632-199907010-00005
    • JS Thalgou K Fritts JM Giuffre 1999 Anterior interbody fusion of the cervical spine with coralline hydroxyapatite Spine 24 1295 1299 10.1097/00007632-199907010-00005 (Pubitemid 29300342)
    • (1999) Spine , vol.24 , Issue.13 , pp. 1295-1299
    • Thalgott, J.S.1    Fritts, K.2    Giuffre, J.M.3    Timlin, M.4
  • 6
    • 0035873098 scopus 로고    scopus 로고
    • A new anterior cervical instrumentation system combining an intradiscal cage with an integrated plate: An early technical report
    • DOI 10.1097/00007632-200105150-00021
    • G Samandouras M Shafafy PJ Hhamlyn 2001 A new anterior cervical instrumentation system combining an intradiscal cage with an integrated plate: an early technical report Spine 26 1188 1192 11413436 10.1097/00007632- 200105150-00021 1:STN:280:DC%2BD3MzkvVWgsA%3D%3D (Pubitemid 32429324)
    • (2001) Spine , vol.26 , Issue.10 , pp. 1188-1192
    • Samandouras, G.1    Shafafy, M.2    John Hamlyn, P.3
  • 7
    • 0034813267 scopus 로고    scopus 로고
    • Reoperation rates for acute graft extrusion and pseudarthrosis after one-level anterior corpectomy and fusion with and without plate instrumentation: Etiology and corrective management
    • DOI 10.1016/S0090-3019(01)00523-7, PII S0090301901005237
    • NE Epstein 2001 Reoperation rates for acute graft extrusion and pseudarthrosis after one-level anterior corpectomy and fusion with and without plate instrumentation: etiology and corrective management Surg Neurol 56 73 80 11580933 10.1016/S0090-3019(01)00523-7 1:STN:280:DC%2BD3MrjsV2mug%3D%3D (Pubitemid 32907217)
    • (2001) Surgical Neurology , vol.56 , Issue.2 , pp. 73-81
    • Epstein, N.E.1
  • 8
    • 33747843016 scopus 로고    scopus 로고
    • Complications and long-term follow-up results in titanium mesh cage reconstruction after cervical corpectomy
    • DOI 10.1097/01.bsd.0000210113.09521.aa, PII 0002472020060700000010
    • H Nakase YS Park H Kimura, et al. 2006 Complications and long-term follow-up results in titanium mesh cage reconstruction after cervical corpectomy J Spinal Disord Tech 19 353 357 16826008 10.1097/01.bsd.0000210113.09521.aa (Pubitemid 44284112)
    • (2006) Journal of Spinal Disorders and Techniques , vol.19 , Issue.5 , pp. 353-357
    • Nakase, H.1    Park, Y.-S.2    Kimura, H.3    Sakaki, T.4    Morimoto, T.5
  • 9
    • 0018934268 scopus 로고
    • Autogenous cortical bone grafts in the reconstruction of segmental skeletal defects
    • WF Enneking JL Eady H Burchardt 1980 Autogenous cortical bone grafts in the reconstruction of segmental skeletal defects J Bone Joint Surg Am 62 1039 1058 7000788 1:STN:280:DyaL3M%2FkslSjtw%3D%3D (Pubitemid 10024535)
    • (1980) Journal of Bone and Joint Surgery - Series A , vol.62 , Issue.7 , pp. 1039-1058
    • Enneking, W.F.1    Eady, J.L.2    Burchardt, H.3
  • 10
    • 29444461041 scopus 로고    scopus 로고
    • The transmission of stress to grafted bone inside a titanium mesh cage used in anterior column reconstruction after total spondylectomy: A finite-element analysis
    • DOI 10.1097/01.brs.0000192281.53603.3f
    • T Akamaru N Kawahara J Sakamoto, et al. 2005 The transmission of stress to grafted bone inside a titanium mesh cage Used in anterior column reconstruction after total spondylectomy: a finite-element analysis Spine 30 2783 2787 16371903 10.1097/01.brs.0000192281.53603.3f (Pubitemid 43011040)
    • (2005) Spine , vol.30 , Issue.24 , pp. 2783-2787
    • Akamaru, T.1    Kawahara, N.2    Sakamoto, J.3    Yoshida, A.4    Murakami, H.5    Hato, T.6    Awamori, S.7    Oda, J.8    Tomita, K.9
  • 11
    • 0025486317 scopus 로고
    • An approach for time-dependent bone modeling and remodeling - theoretical development
    • GS Beaupe TE Orr DR Carter 1990 An approach for time-dependent bone modeling and remodeling-theoretical development J Orthop Res 8 651 661 10.1002/jor.1100080506 (Pubitemid 20303669)
    • (1990) Journal of Orthopaedic Research , vol.8 , Issue.5 , pp. 651-661
    • Beaupre, G.S.1    Orr, T.E.2    Carter, D.R.3
  • 12
    • 0025484692 scopus 로고
    • An approach for time-dependent bone modeling and remodeling - application: A preliminary remodeling simulation
    • GS Beaupe TE Orr DR Carter 1990 An approach for time-dependent bone modeling and remodeling-application: a preliminary remodeling simulation J Orthop Res 8 662 670 10.1002/jor.1100080507 (Pubitemid 20303670)
    • (1990) Journal of Orthopaedic Research , vol.8 , Issue.5 , pp. 662-670
    • Beaupre, G.S.1    Orr, T.E.2    Carter, D.R.3
  • 13
    • 0015301185 scopus 로고
    • Mechanical influences in bone remodeling. Experimental research on Wolff's law
    • 5020948 10.1016/0021-9290(72)90053-X 1:STN:280:DyaE387ms1Wlsw%3D%3D
    • A Chamay P Tschantz 1972 Mechanical influences in bone remodeling. Experimental research on Wolff's law J Biomech 5 173 180 5020948 10.1016/0021-9290(72)90053-X 1:STN:280:DyaE387ms1Wlsw%3D%3D
    • (1972) J Biomech , vol.5 , pp. 173-180
    • Chamay, A.1    Tschantz, P.2
  • 14
    • 0025807515 scopus 로고
    • Axial movement and tibial fractures: A controlled randomized trial of treatment
    • 2071654 1:STN:280:DyaK3Mzgt1Cntw%3D%3D
    • J Kenwright JB Richardson JL Cunningham, et al. 1991 Axial movement and tibial fractures: a controlled randomized trial of treatment J Bone Joint Surg Br 73 654 659 2071654 1:STN:280:DyaK3Mzgt1Cntw%3D%3D
    • (1991) J Bone Joint Surg Br , vol.73 , pp. 654-659
    • Kenwright, J.1    Richardson, J.B.2    Cunningham, J.L.3
  • 15
    • 0028533208 scopus 로고
    • Effects of fit and bonding characteristics of femoral stems on adaptive bone remodeling
    • H Weinans R Huiskes HJ Grootenboer 1994 Effects of fit and bonding characteristics of femoral stems on adaptive bone remodeling J Biomech Eng 116 393 400 7869714 10.1115/1.2895789 1:STN:280:DyaK2M7nsVegsA%3D%3D (Pubitemid 24376569)
    • (1994) Journal of Biomechanical Engineering , vol.116 , Issue.4 , pp. 393-400
    • Weinans, H.1    Huiskes, R.2    Grootenboer, H.J.3
  • 16
    • 0034464628 scopus 로고    scopus 로고
    • The management of one-level anterior cervical corpectomy with fusion using atlantis hybrid plates: Preliminary experience
    • DOI 10.1097/00002517-200008000-00009
    • NE Epstein 2000 The management of one-level anterior cervical corpectomy with fusion using Atlantis hybrid plate: preliminary experience J Spinal Disord Tech 13 324 328 10.1097/00002517-200008000-00009 1:STN:280: DC%2BD3M%2FjsFWnuw%3D%3D (Pubitemid 32199498)
    • (2000) Journal of Spinal Disorders , vol.13 , Issue.4 , pp. 324-328
    • Epstein, N.E.1
  • 17
    • 0037222667 scopus 로고    scopus 로고
    • Anterior cervical arthrodesis using DOC dynamic stabilization implant for improvement in sagittal angulation and controlled settling
    • B Bose 2003 Anterior cervical arthrodesis using DOC dynamic stabilization implant for improvement in sagittal angulation and controlled settling J Neurosurg 98 8 13 12546382 10.3171/jns.2003.98.1.0008 (Pubitemid 36050477)
    • (2003) Journal of Neurosurgery , vol.98 , Issue.1 , pp. 8-13
    • Bose, B.1
  • 18
    • 53349163293 scopus 로고    scopus 로고
    • Anterior cervical stabilization using a semi-constrained cervical plate and titanium mesh cage for single level corpectomy
    • 18801657 10.1016/j.jocn.2007.09.019 1:CAS:528:DC%2BD1cXht1ejtbzJ
    • SH Lee JK Sung 2008 Anterior cervical stabilization using a semi-constrained cervical plate and titanium mesh cage for single level corpectomy J Clin Neurosci 15 1227 1234 18801657 10.1016/j.jocn.2007.09.019 1:CAS:528:DC%2BD1cXht1ejtbzJ
    • (2008) J Clin Neurosci , vol.15 , pp. 1227-1234
    • Lee, S.H.1    Sung, J.K.2
  • 19
    • 0023802243 scopus 로고    scopus 로고
    • Arthrodesis by the distraction-compress method using a stainless steel implant
    • GW Bagby 1998 Arthrodesis by the distraction-compress method using a stainless steel implant Orthop 11 931 934
    • (1998) Orthop , vol.11 , pp. 931-934
    • Bagby, G.W.1
  • 20
    • 0036729155 scopus 로고    scopus 로고
    • Graft subsidence after instrument-assisted anterior cervical fusion
    • 12296677
    • GW Tye RS Graham WC Broaddus, et al. 2002 Graft subsidence after instrument-assisted anterior cervical fusion J Neurosurg 97 186 192 12296677
    • (2002) J Neurosurg , vol.97 , pp. 186-192
    • Tye, G.W.1    Graham, R.S.2    Broaddus, W.C.3
  • 21
    • 0242488005 scopus 로고    scopus 로고
    • Subsidence of stand-alone cervical cages in anterior interbody fusion: Warning
    • DOI 10.1007/s00586-003-0539-6
    • E Gercek V Arlet J Delisle, et al. 2003 Subsidence of stand-alone cervical cages in anterior interbody fusion: warning Eur Spine J 12 513 516 12827473 10.1007/s00586-003-0539-6 (Pubitemid 37409951)
    • (2003) European Spine Journal , vol.12 , Issue.5 , pp. 513-516
    • Gercek, E.1    Arlet, V.2    Delisle, J.3    Marchesi, D.4
  • 22
    • 28044451810 scopus 로고    scopus 로고
    • Anterior cervical interbody fusion with a titanium box cage: Early radiological assessment of fusion and subsidence
    • DOI 10.1016/j.spinee.2005.07.007, PII S1529943005008752
    • HP van Jonbergen M Spruit PG Anderson, et al. 2005 Anterior cervical interbody fusion with a titanium box cage: early radiological assessment of fusion and subsidence Spine J 5 645 649 16291105 10.1016/j.spinee.2005.07.007 (Pubitemid 41683746)
    • (2005) Spine Journal , vol.5 , Issue.6 , pp. 645-649
    • Van Jonbergen, H.-P.W.1    Spruit, M.2    Anderson, P.G.3    Pavlov, P.W.4
  • 23
    • 33644499177 scopus 로고    scopus 로고
    • Cervical foraminal area and intervertebral height changes after titanium ring cage placement: Preliminary results
    • DOI 10.1016/j.jocn.2005.03.035, PII S0967586806000130
    • ME Colpan A Attar Z Sekerci, et al. 2006 Cervical foraminal area and intervertebral height changes after titanium ring cage placement: preliminary results J Clin Neurosci 13 228 232 16503486 10.1016/j.jocn.2005.03.035 (Pubitemid 43294479)
    • (2006) Journal of Clinical Neuroscience , vol.13 , Issue.2 , pp. 228-232
    • Colpan, M.E.1    Attar, A.2    Sekerci, Z.3    Tuna, H.4    Egemen, N.5
  • 24
    • 58149183965 scopus 로고    scopus 로고
    • Comparative biomechanical study of cervical spine stabilisation by cage alone, cage with plate, or plate-cage: A porcine model
    • 1:STN:280:DC%2BD1c3ptlWkuw%3D%3D
    • J Hakalo C Pezowicz J Wronski, et al. 2008 Comparative biomechanical study of cervical spine stabilisation by cage alone, cage with plate, or plate-cage: a porcine model J Orthop Surg 16 9 13 1:STN:280: DC%2BD1c3ptlWkuw%3D%3D
    • (2008) J Orthop Surg , vol.16 , pp. 9-13
    • Hakalo, J.1    Pezowicz, C.2    Wronski, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.