메뉴 건너뛰기




Volumn 98, Issue 1, 2012, Pages 61-67

Dorsally displaced distal radius fractures: Comparative study of Py's and Kapandji's techniques

Author keywords

Distal radius fracture; Intramedullary and intrafocal pinning; K wire distal radius; Percutaneous distal radius fixation

Indexed keywords

ADULT; ARTICLE; BONE NECROSIS; COMPARATIVE STUDY; COMPLEX REGIONAL PAIN SYNDROME; CONTROLLED STUDY; FEMALE; FOLLOW UP; FOREIGN BODY; FRACTURE DISLOCATION; FRACTURE NONUNION; HAND PARESTHESIA; HUMAN; INTRAMEDULLARY NAILING; KAPANDJI INTRAFOCAL PINNING; MAJOR CLINICAL STUDY; MALE; OSTEOTOMY; PHASE 3 CLINICAL TRIAL; POSTOPERATIVE PERIOD; PREOPERATIVE CARE; PRIORITY JOURNAL; PROSPECTIVE STUDY; PY ISOELASTIC PINNING; RADIUS; RADIUS FRACTURE; RANDOMIZED CONTROLLED TRIAL; RANGE OF MOTION; SCORING SYSTEM; TENDON RUPTURE; ULNA; VOLAR PLATE FIXATION;

EID: 84856596396     PISSN: None     EISSN: 18770568     Source Type: Journal    
DOI: 10.1016/j.otsr.2011.09.018     Document Type: Article
Times cited : (8)

References (38)
  • 1
    • 0031808171 scopus 로고    scopus 로고
    • A comparison of 3 and 5 weeks immobilization for older type 1 and 2 Colles' fractures
    • Vang Hansen F., Staunstrup H., Mikkelsen S. A comparison of 3 and 5 weeks immobilization for older type 1 and 2 Colles' fractures. J Hand Surg [Br] 1998, 23:400-401.
    • (1998) J Hand Surg [Br] , vol.23 , pp. 400-401
    • Vang Hansen, F.1    Staunstrup, H.2    Mikkelsen, S.3
  • 3
    • 0017193226 scopus 로고
    • Internal fixation by double intrafocal plate. Functional treatment of non articular fractures of the lower end of the radius (author's transl)
    • Kapandji A. Internal fixation by double intrafocal plate. Functional treatment of non articular fractures of the lower end of the radius (author's transl). Ann Chir 1976, 30:903-908.
    • (1976) Ann Chir , vol.30 , pp. 903-908
    • Kapandji, A.1
  • 4
    • 0026073542 scopus 로고
    • External fixation for intra-articular fractures of the distal radius
    • Jakim I., Pieterse H.S., Sweet M.B. External fixation for intra-articular fractures of the distal radius. J Bone Joint Surg Br 1991, 73:302-306.
    • (1991) J Bone Joint Surg Br , vol.73 , pp. 302-306
    • Jakim, I.1    Pieterse, H.S.2    Sweet, M.B.3
  • 5
    • 0013110832 scopus 로고
    • Reduction and osteosynthesis with pin fixation of wrist fractures. A comparative study between Kapandji's and Py's techniques
    • Delattre O., Saillant G., Lemoine J., Benazet J.P., et al. Reduction and osteosynthesis with pin fixation of wrist fractures. A comparative study between Kapandji's and Py's techniques. Rev Chir Orthop Reparatrice Appar Mot 1994, 80:94-107.
    • (1994) Rev Chir Orthop Reparatrice Appar Mot , vol.80 , pp. 94-107
    • Delattre, O.1    Saillant, G.2    Lemoine, J.3    Benazet, J.P.4
  • 6
    • 0034840307 scopus 로고    scopus 로고
    • The DASH questionnaire. French translation of a trans-cultural adaptation
    • Dubert T., Voche P., Dumontier C., Dinh A. The DASH questionnaire. French translation of a trans-cultural adaptation. Chir Main 2001, 20:294-302.
    • (2001) Chir Main , vol.20 , pp. 294-302
    • Dubert, T.1    Voche, P.2    Dumontier, C.3    Dinh, A.4
  • 7
    • 0031981551 scopus 로고    scopus 로고
    • Metaphysis fracture of the distal radius: Kapandji's or Py's pinning?
    • Fikry T., Fadili M., Harfaoui A., Dkhissi M., et al. Metaphysis fracture of the distal radius: Kapandji's or Py's pinning?. Ann Chir Main Memb Super 1998, 17:31-40.
    • (1998) Ann Chir Main Memb Super , vol.17 , pp. 31-40
    • Fikry, T.1    Fadili, M.2    Harfaoui, A.3    Dkhissi, M.4
  • 8
    • 0008901144 scopus 로고    scopus 로고
    • Apropos of the article: " Reduction and synthesis of wrist fractures: comparative study of the method of Kapandji and that of Py"
    • Desmanet E. Apropos of the article: " Reduction and synthesis of wrist fractures: comparative study of the method of Kapandji and that of Py" Rev Chir Orthop Reparatrice Appar Mot 1996, 82:672.
    • (1996) Rev Chir Orthop Reparatrice Appar Mot , vol.82 , pp. 672
    • Desmanet, E.1
  • 9
    • 0034933014 scopus 로고    scopus 로고
    • Unstable fracture of the distal radius and its treatment: comparison of three techniques: external fixation, intramedullary pinning and AO plates
    • Sennwald G.R., Della Santa D. Unstable fracture of the distal radius and its treatment: comparison of three techniques: external fixation, intramedullary pinning and AO plates. Chir Main 2001, 20:218-225.
    • (2001) Chir Main , vol.20 , pp. 218-225
    • Sennwald, G.R.1    Della Santa, D.2
  • 10
    • 0026018870 scopus 로고
    • Unstable Colles' fractures in elderly patients. A randomised trial of external fixation for redisplacement
    • Roumen R.M., Hesp W.L., Bruggink E.D.F. Unstable Colles' fractures in elderly patients. A randomised trial of external fixation for redisplacement. J Bone Joint Surg Br 1991, 73:307-311.
    • (1991) J Bone Joint Surg Br , vol.73 , pp. 307-311
    • Roumen, R.M.1    Hesp, W.L.2    Bruggink, E.D.F.3
  • 11
    • 0031793292 scopus 로고    scopus 로고
    • Osteosynthesis of distal radius fractures by by flexible intramedullary nailing (Geneva experience)
    • Flisch C.W., Della Santa D.R. Osteosynthesis of distal radius fractures by by flexible intramedullary nailing (Geneva experience). Chir Main 1998, 17:245-254.
    • (1998) Chir Main , vol.17 , pp. 245-254
    • Flisch, C.W.1    Della Santa, D.R.2
  • 12
    • 0035203365 scopus 로고    scopus 로고
    • Is there still a place for conservative treatment of distal radius fractures in the adult?
    • Della Santa D., Sennwald G. Is there still a place for conservative treatment of distal radius fractures in the adult?. Chir Main 2001, 20:426-435.
    • (2001) Chir Main , vol.20 , pp. 426-435
    • Della Santa, D.1    Sennwald, G.2
  • 13
    • 0035711984 scopus 로고    scopus 로고
    • Mechanical strength of intramedullary pinning and transfragmental Kirschner wire fixation for Colles' fractures
    • Saeki Y., Hashizume H., Nagoshi M., Tanaka H., et al. Mechanical strength of intramedullary pinning and transfragmental Kirschner wire fixation for Colles' fractures. J Hand Surg [Br] 2001, 26:550-555.
    • (2001) J Hand Surg [Br] , vol.26 , pp. 550-555
    • Saeki, Y.1    Hashizume, H.2    Nagoshi, M.3    Tanaka, H.4
  • 14
    • 0033930196 scopus 로고    scopus 로고
    • Comparison of intramedullary fixation and percutaneous pinning of displaced and comminuted Colles' fractures: a prospective and consecutive study
    • Hede J.S., Lindblad B.E., Mikkelsen S.S., Knudsen H.M. Comparison of intramedullary fixation and percutaneous pinning of displaced and comminuted Colles' fractures: a prospective and consecutive study. Scand J Plast Reconstr Surg Hand Surg 2000, 34:161-166.
    • (2000) Scand J Plast Reconstr Surg Hand Surg , vol.34 , pp. 161-166
    • Hede, J.S.1    Lindblad, B.E.2    Mikkelsen, S.S.3    Knudsen, H.M.4
  • 15
    • 33846101160 scopus 로고    scopus 로고
    • Predictors of functional outcomes after surgical treatment of distal radius fractures
    • Chung K.C., Kotsis S.V., Kim H.M. Predictors of functional outcomes after surgical treatment of distal radius fractures. J Hand Surg [Am] 2007, 32:76-83.
    • (2007) J Hand Surg [Am] , vol.32 , pp. 76-83
    • Chung, K.C.1    Kotsis, S.V.2    Kim, H.M.3
  • 17
    • 35948934685 scopus 로고    scopus 로고
    • A comparative study of clinical and radiological outcomes of dorsally angulated, unstable distal radius fractures in elderly patients: intrafocal pinning versus volar locking plating
    • Oshige T., Sakai A., Zenke Y., Moritani S., et al. A comparative study of clinical and radiological outcomes of dorsally angulated, unstable distal radius fractures in elderly patients: intrafocal pinning versus volar locking plating. J Hand Surg [Am] 2007, 32:1385-1392.
    • (2007) J Hand Surg [Am] , vol.32 , pp. 1385-1392
    • Oshige, T.1    Sakai, A.2    Zenke, Y.3    Moritani, S.4
  • 18
    • 0030839729 scopus 로고    scopus 로고
    • Do we underestimate the predictive value of the ulnar styloid affection in Colles fractures?
    • Oskarsson G.V., Aaser P., Hjall A. Do we underestimate the predictive value of the ulnar styloid affection in Colles fractures?. Arch Orthop Trauma Surg 1997, 116:341-344.
    • (1997) Arch Orthop Trauma Surg , vol.116 , pp. 341-344
    • Oskarsson, G.V.1    Aaser, P.2    Hjall, A.3
  • 20
    • 47849099779 scopus 로고    scopus 로고
    • Comparative outcomes study using the volar locking plating system for distal radius fractures in both young adults and adults older than 60 years
    • Chung K.C., Squitieri L., Kim H.M. Comparative outcomes study using the volar locking plating system for distal radius fractures in both young adults and adults older than 60 years. J Hand Surg [Am] 2008, 33:809-819.
    • (2008) J Hand Surg [Am] , vol.33 , pp. 809-819
    • Chung, K.C.1    Squitieri, L.2    Kim, H.M.3
  • 21
    • 33751515068 scopus 로고    scopus 로고
    • Trans-styloid and intrafocal pinning for extra-articular extension fractures of the distal radius: prospective randomized postoperative comparison with simple intra-focal pinning
    • Gravier R., Flecher X., Parratte S., Rapaie P., et al. Trans-styloid and intrafocal pinning for extra-articular extension fractures of the distal radius: prospective randomized postoperative comparison with simple intra-focal pinning. Rev Chir Orthop Reparatrice Appar Mot 2006, 92:657-662.
    • (2006) Rev Chir Orthop Reparatrice Appar Mot , vol.92 , pp. 657-662
    • Gravier, R.1    Flecher, X.2    Parratte, S.3    Rapaie, P.4
  • 23
    • 9444250509 scopus 로고    scopus 로고
    • Fractures of the distal radius treated by osteosynthesis and injectable bone substitute: a prospective study of 39 patients
    • Obert L., Leclerc G., Lepage D., Forterre O., et al. Fractures of the distal radius treated by osteosynthesis and injectable bone substitute: a prospective study of 39 patients. Rev Chir Orthop Reparatrice Appar Mot 2004, 90:613-620.
    • (2004) Rev Chir Orthop Reparatrice Appar Mot , vol.90 , pp. 613-620
    • Obert, L.1    Leclerc, G.2    Lepage, D.3    Forterre, O.4
  • 24
    • 0029041794 scopus 로고
    • Fracture of the distal radius. A prospective comparison between trans-styloid and Kapandji fixations
    • Lenoble E., Dumontier C., Goutallier D., Apoil A. Fracture of the distal radius. A prospective comparison between trans-styloid and Kapandji fixations. J Bone Joint Surg Br 1995, 77:562-567.
    • (1995) J Bone Joint Surg Br , vol.77 , pp. 562-567
    • Lenoble, E.1    Dumontier, C.2    Goutallier, D.3    Apoil, A.4
  • 25
    • 0038726342 scopus 로고    scopus 로고
    • A 36 month prospective study of 12 plate osteosyntheses of distal radius fractures
    • Limousin M., Benoit O., Chantelot C., Gueguen G., et al. A 36 month prospective study of 12 plate osteosyntheses of distal radius fractures. Chir Main 2003, 22:138-143.
    • (2003) Chir Main , vol.22 , pp. 138-143
    • Limousin, M.1    Benoit, O.2    Chantelot, C.3    Gueguen, G.4
  • 26
    • 0031751641 scopus 로고    scopus 로고
    • Kapandji pinning or closed reduction for extra-articular distal radius fractures
    • Stoffelen D.V., Broos P.L. Kapandji pinning or closed reduction for extra-articular distal radius fractures. J Trauma 1998, 45:753-757.
    • (1998) J Trauma , vol.45 , pp. 753-757
    • Stoffelen, D.V.1    Broos, P.L.2
  • 27
    • 0035203367 scopus 로고    scopus 로고
    • Osteosynthesis of distal radius fractures by doral plate: advantages and disadvantages
    • Obert L., Vichard P., Garbuio P., Tropet Y. Osteosynthesis of distal radius fractures by doral plate: advantages and disadvantages. Chir Main 2001, 20:436-446.
    • (2001) Chir Main , vol.20 , pp. 436-446
    • Obert, L.1    Vichard, P.2    Garbuio, P.3    Tropet, Y.4
  • 28
    • 34447536540 scopus 로고    scopus 로고
    • Using the DRP 2.4 device for volar plating of distal radius for dorsally displaced wrist fractures. Report of 22 cases
    • Pichon H., Martin des Pallieres T., Rubens Duval B., Carpentier E., et al. Using the DRP 2.4 device for volar plating of distal radius for dorsally displaced wrist fractures. Report of 22 cases. Chir Main 2007, 26:127-135.
    • (2007) Chir Main , vol.26 , pp. 127-135
    • Pichon, H.1    Martin des Pallieres, T.2    Rubens Duval, B.3    Carpentier, E.4
  • 30
    • 27744514918 scopus 로고    scopus 로고
    • Do Kirschner wires maintain reduction of displaced Colles' fractures?
    • Barton T., Chambers C., Lane E., Bannister G. Do Kirschner wires maintain reduction of displaced Colles' fractures?. Injury 2005, 36:1431-1434.
    • (2005) Injury , vol.36 , pp. 1431-1434
    • Barton, T.1    Chambers, C.2    Lane, E.3    Bannister, G.4
  • 31
    • 34250809697 scopus 로고    scopus 로고
    • Open reduction and internal locked fixation of unstable distal ulna fractures with concomitant distal radius fracture
    • Dennison D.G. Open reduction and internal locked fixation of unstable distal ulna fractures with concomitant distal radius fracture. J Hand Surg [Am] 2007, 32:801-805.
    • (2007) J Hand Surg [Am] , vol.32 , pp. 801-805
    • Dennison, D.G.1
  • 32
    • 0034750196 scopus 로고    scopus 로고
    • Interest in wrist arthroscopy for treatment of articular fractures of the distal radius: report of 27 cases
    • Mathoulin C., Sbihi A., Panciera P. Interest in wrist arthroscopy for treatment of articular fractures of the distal radius: report of 27 cases. Chir Main 2001, 20:342-350.
    • (2001) Chir Main , vol.20 , pp. 342-350
    • Mathoulin, C.1    Sbihi, A.2    Panciera, P.3
  • 33
    • 0023616263 scopus 로고
    • The radiological deformity of Colles' fractures
    • Dias J.J., Wray C.C., Jones J.M. The radiological deformity of Colles' fractures. Injury 1987, 18:304-308.
    • (1987) Injury , vol.18 , pp. 304-308
    • Dias, J.J.1    Wray, C.C.2    Jones, J.M.3
  • 34
    • 33751070334 scopus 로고    scopus 로고
    • Arthroscopic treatment of distal radius fracture
    • Lindau T. Arthroscopic treatment of distal radius fracture. Chir Main 2006, 25(Suppl. 1):S161-S170.
    • (2006) Chir Main , vol.25 , Issue.SUPPL. 1
    • Lindau, T.1
  • 35
    • 33845734224 scopus 로고    scopus 로고
    • Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures
    • Al-Rashid M., Theivendran K., Craigen M.A. Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures. J Bone Joint Surg Br 2006, 88:1610-1612.
    • (2006) J Bone Joint Surg Br , vol.88 , pp. 1610-1612
    • Al-Rashid, M.1    Theivendran, K.2    Craigen, M.A.3
  • 36
    • 24944578870 scopus 로고    scopus 로고
    • Rupture of the flexor tendons on an anterior plate for distal radial fracture: four cases and a review of the literature
    • Cognet J.M., Dujardin C., Popescu A., Gouzou S., et al. Rupture of the flexor tendons on an anterior plate for distal radial fracture: four cases and a review of the literature. Rev Chir Orthop Reparatrice Appar Mot 2005, 91:476-481.
    • (2005) Rev Chir Orthop Reparatrice Appar Mot , vol.91 , pp. 476-481
    • Cognet, J.M.1    Dujardin, C.2    Popescu, A.3    Gouzou, S.4
  • 37
    • 39149097204 scopus 로고    scopus 로고
    • Flexor tendon injuries following locked volar plating of distal radius fractures
    • Cross A.W., Schmidt C.C. Flexor tendon injuries following locked volar plating of distal radius fractures. J Hand Surg [Am] 2008, 33:164-167.
    • (2008) J Hand Surg [Am] , vol.33 , pp. 164-167
    • Cross, A.W.1    Schmidt, C.C.2
  • 38
    • 0005963075 scopus 로고
    • Intra-focal pinning of fractures of the distal end of the radius 10 years later
    • Kapandji A. Intra-focal pinning of fractures of the distal end of the radius 10 years later. Ann Chir Main 1987, 6:57-63.
    • (1987) Ann Chir Main , vol.6 , pp. 57-63
    • Kapandji, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.